What is refuted here — page 29
Right mechanism, wrong accounting — continued
The physics named is the physics acting. The sum that usually accompanies it does not come out, and the missing term is generally the one that decides. 462 claims in this group.
A column's reinforcement adds a small stiffness in proportion to its area, about ten per cent at 2% steel, so a shortening calculation may leave it out.
What decides it: That is the first day: 316 against 353 microstrain at 12 MPa. Over the column's life the concrete sheds load into the bars, and the final strain is 1,067 against 1,429, a quarter less. Up a tower, the difference between column and core at the roof falls from 42 to 16 mm with the column at 2% and the core at 0.5%.
Tested in The bars that take the column over, at the figure it turns on · the essays about differential shortening.
A column with more steel is safer in every respect, and an upper limit on steel is only about getting the concrete in.
What decides it: Removing the sustained load leaves the concrete in tension, because the bars recover and the crept concrete cannot. From 12 MPa, a 2% column stands at 3 MPa of tension and a 4% column at 4.5, with no load on it, enough to crack the concrete right through at intervals.
Tested in The bars that take the column over, at the figure it turns on · the essays about differential shortening.
An internal pressure coefficient is a property of a building's openings that can be read from a table once the dominant face is known.
What decides it: It is the root of a flow balance over every opening and every external coefficient. A windward opening of 1 m² takes the inside from −0.44 to −0.08 and one of 4.8 m² takes it to +0.60, in a building leaking 3 m² in all. It is the ratio to the rest that decides, and the table is two points on that curve.
Tested in The pressure the openings decide, at the figure it turns on · the essays about wind pressure.
A wide strip of plate bends with the plate stiffness E/(1 − ν²), and a narrow one with E, so the width decides which to use.
What decides it: Width alone decides nothing. A free-edged 1,000 × 12 mm plate bent to its service deflection stands at Searle's number 1.07, where the stiffness is 1.003 of the beam's. It is the combination of the width and the curvature, b²/(Rt), that decides, and it takes a value around 30 to reach most of the gain. Edges that are held supply the plate's stiffness at any curvature.
Tested in The strip that becomes a plate, at the figure it turns on · the essays about elastic modulus.
Removing material from the extreme fibres of a section always weakens it, since those fibres have the largest lever arm.
What decides it: It always lowers the plastic moment. It raises the first-yield moment whenever the fibres at the edge are narrow enough: a diamond cut to 8/9 of its half-depth gains 5.35% in its elastic modulus while losing 3.4% of its plastic modulus and 1.2% of its area.
Tested in The section stronger for being cut, at the figure it turns on · the essays about shape factor.
A membrane analysis gives a hyperbolic paraboloid's deflection as well as its stress, so a shallow roof that passes on stress is finished.
What decides it: Stress is found with no reference to the edges' stiffness, and the deflection depends on nearly nothing else. At 1 m of rise, the same 2 kPa gives a deflection of 66 mm with an edge member of 0.04 m² and 13 mm with one of 1.28 m², while the shear in the sheet is about 100 kN/m in both.
Tested in The roof that carries everything as shear, at the figure it turns on · the essays about shell action.
Clearance holes cost a bolted splice its strength only through the bolts' bearing, so a splice whose plates yield before its bolts shear is as good in clearance holes as with fitted bolts.
What decides it: Its plastic moment is unchanged at 1,164 kN·m, because every plate yields before its bolts shear. But the first plate yields at 752 kN·m with the bolts centred, and at 392 at the 5% fractile of random fit-ups, against 936 preloaded — inside the design moment of 700 on one fit-up in twenty — and the splice turns 11.7 mrad at the design moment against 1.6.
Tested in The splice that waits for its covers, at the figure it turns on · the essays about single lap.
Once a K-braced girder has several joints where two K's meet, its redundancies interact, and every one must be solved together with the others before any member force is known.
What decides it: Each shared joint adds one self-stress state that lives in its own two panels. Where turns are far apart the states share no member; where they alternate, each pair shares one full-height vertical, and the cross term between them is 3% of each state's own flexibility. A vertical load calls on a state only through its own members, so for most loads a section calculation that ignores all of them is exact.
Tested in The push the shared joints were waiting for, at the figure it turns on · the essays about method of sections.
A bent spiral seam fails at the points of each turn where it crosses the line the local stress does not stretch, because the parent lends it nothing there.
What decides it: It fails at the most stretched fibre, where at 100 N/mm² of hoop stress the local unstretched line is at 77° against the seam's 60° and the parent's help is 1.02 rather than one. The line's nearness matters more than an exact crossing: a quarter turn away, where the stress is lower, the help is 1.32.
Tested in The bend that finds the seam's line, at the figure it turns on · the essays about Heat-affected zone.
Clearance in a cross-frame's bolts can only matter to the frame itself, since the box around it is designed for the distortion it would have with no frame at all.
What decides it: The box's worst range is indeed almost unchanged, 0.52 mrad tight and 0.53 with a millimetre of clearance. But the plate within a few metres of the frame goes from 0.21 to 0.50, and a detail there from 15.5 times the box's shortest life to 1.15. If the frame's own detail is three categories worse than the plain plate, its life goes from 5.33 times the plate's shortest to 0.42 of it, and the box's critical detail is now at the frame.
Tested in The plate the loose frame stops protecting, at the figure it turns on · the essays about box distortion.
An earthquake at right angles to the wind's swing of a tuned mass costs its stops nothing, because the wind has used the stroke in the other direction.
What decides it: True of a mass on two tracks with a pair of stops on each: at 0.5 m/s² across a wind that swings it ±0.40 m it is struck 0.5 times a record, as in calm air. A mass inside a ring of stops is struck 2.6 times, because its two strokes add as a vector and the ring is 0.30 m away at the ends of the wind's swing.
Tested in The ring the mass swings inside, at the figure it turns on · the essays about damping.
A continuity joint can be set, by jacking the beams as it is cast, so that the restraint moment creep and shrinkage bring it to is cancelled at thirty years, whatever date the programme gives the slab.
What decides it: The arithmetic works for any date, but the beams' creep relaxes the jacked moment to 0.39 to 0.53 of itself, so the jack is two to three times the moment it cancels: 413 kN·m of hog for a slab at six weeks, 407 of sag for one at a year. Both exceed the joint's cracking moments, 239 in hog and 140 in sag. Held to those, the jack leaves 67 kN·m at six weeks and 140 at a year.
Tested in The joint born holding a moment, at the figure it turns on · the essays about end rotation.
Safe rather than true
Not a misconception so much as a simplification that has stopped being labelled as one. Each of these errs on the safe side in the case it was chosen for — and each has a direction in which it does not. 5 claims in this group.
Truss joints are pins, so truss members carry axial force and nothing else.
What decides it: The same truss solved twice — pin-jointed, and with the joints continuous as welding actually makes them. The axial forces agree to about a per cent, which is why the idealisation is a good one; the bending it omits reaches a quarter of the axial stress in the worst member. It scales with EI/L, so a stocky truss of heavy members suffers more of it than a light one — which is the opposite of the way most reserves of strength work, and is the direction in which the simplification stops erring safe.
Tested in The joint that is not a pin, at the figure it turns on · the essays about truss.
Wind loading is a static problem: work out the pressure, multiply by the area, apply it.
What decides it: True for a stiff structure and badly wrong for a slender one. Split into its parts, a warehouse at 2 Hz takes 15% of its fluctuating response from resonance and a tower at 0.2 Hz takes 90% — and the resonant part is inversely proportional to a damping ratio that no static calculation contains. The static method survives because the gust factor it hides absorbs the difference for ordinary buildings.
Tested in The wind is a spectrum, at the figure it turns on · the essays about gust response.
The effective width of a flange is min(span/8, b) per side, and that expression comes from the elasticity of the problem.
What decides it: The exact elastic ceiling for an infinitely wide flange fed by a sinusoidal shear flow is L/2π = 0.1592L per side, from Airy's solution. The rule caps at L/8 = 0.125L, which is 0.7854 of it — exactly 2π/8. A rule that is a fixed fraction of the exact answer is a fit with a margin in it, not a derivation of it, and it is a straight line where the elasticity is a curve.
Tested in The flange that is not all there, at the figure it turns on · the essays about effective width.
Quoting k = 4 for a long plate is an approximation, so it could be wrong in either direction.
What decides it: It is the floor of the envelope and not an average through it. Every scallop rises above 4 and none falls below it, so the quoted value understates the critical stress by up to 12.5 per cent and never overstates it — and past an aspect ratio of 1.60 the error can never exceed 5 per cent again.
Tested in Four was never a fact about plates, at the figure it turns on · the essays about plate buckling.
One pass of the effective-width calculation is enough, because the correction is small.
What decides it: It is small in the moment and not in the width. One pass reports 278 mm of web removed against the converged 323, understating the loss by 16 per cent, while the moment capacity it reports is 10,079 kNm against 9,999 — an error of 0.8 per cent. The two errors differ by a factor of twenty because the width that goes missing sits near the neutral axis.
Tested in Classified by a gradient it does not have, at the figure it turns on · the essays about plate buckling.