Series
Box distortion — the series
2 essays on one idea, from the one that introduces it to the one that assumes the rest.
-
The section that will not keep its shape
A box girder is closed, so torsion costs it almost nothing. What an eccentric load actually does to it is something a torsion calculation contains no term for — the rectangle becomes a parallelogram, in its own plane, along the whole length of the span.
-
One diaphragm is nearly none
A box girder's distortion decays over a length the section decides, and on a sixty-metre span that length is twenty-four metres. So a single diaphragm at midspan sits further from each end than the distortion can reach and removes a third of the problem; three diaphragms remove nine tenths. The spacing rule is not span over five — it is a property of the plates.