Sections and stress

The plate the loose frame stops protecting

A cross-frame bolted through clearance holes does nothing until a lorry has distorted the box far enough to take up the hole, and among ring frames a millimetre is nearly the whole distortion a lorry produces. What that costs is not the frame's own life but the plates' around it. A tight frame holds the corner angle's range to 0.21 mrad over a few metres either side of itself; a millimetre of clearance lets it rise to 0.50, and a detail there loses a factor of thirteen in fatigue life. The box's worst place does not move, because it was never at the frame. The critical detail moves only if the frame's own detail is a worse category than the plain plate's, which it usually is.

Assumes The section that will not keep its shape, The load that never came near failing anything and The joint that carries nothing until it slips.

The frame that waits for a heavy lorry found that a cross-frame bolted through a clearance hole is a dead band in the box’s corner angle. A millimetre of clearance in a diagonal is 0.47 mrad of distortion through which the frame carries nothing, and among ring frames a 440 kN lorry produces only about 0.49. Its argument was about the frame: the diagonal’s stress range falls from 19.3 N/mm² to almost nothing, and over a spectrum of lorries the frame’s own fatigue becomes trivial. A loose frame is a frame that rarely works, so it rarely tires.

That is good news for the diagonal and silent about everything else. A cross-frame is not in a box for its own sake. It is there to hold the box’s cross-section square, and the things that suffer when the section does not stay square are the plates: the walls bend transversely as the corners open and close, and every detail welded to them — a stiffener’s end, a frame’s gusset, the toe of the weld that joins a ring frame’s web to the box wall — sees a stress that follows the corner angle. The earlier essay ended on the question that follows. A tight frame protects some length of plate around itself; a loose one stops doing so. Whether a plate detail near the frame loses a large factor of its life to an unused hole, or whether the same detail midway between frames never noticed there was a frame at all, decides whether a fitting tolerance has moved the critical place along the box.

The angle that the plates follow

The box is the one both earlier essays used, the distorting box of the section that will not keep its shape with ring frames added: 60 m long, simply supported, 4 m wide and 2.5 m deep, its distortion governed by a beam on an elastic foundation,

EIdw γ′′′′+Kd γ=m2,EI_{dw}\,\gamma'''' + K_d\,\gamma = \frac{m}{2},

in which γ\gamma is the change of corner angle, EIdwEI_{dw} the box’s warping stiffness against distortion and KdK_d the transverse stiffness of the walls and the ring frames smeared together, with a decay length of about 6.6 m. Cross-frames stand at 20 m and 40 m, each a pair of angle diagonals that are a hard spring on that foundation once their bolts bear and nothing before. The lorry is four axles, 440 kN in all, running 1.5 m off the box’s centre line, and it crosses the span in sixty steps.

The step this essay adds is to take every distortional stress in the plates as proportional to γ\gamma where it stands. That is the assumption the figures rest on, and it is a good one for the stresses that matter in fatigue: the transverse bending moment in a wall, the force in a stiffener’s end, the distortion-induced stress at a frame’s connection are all linear in the corner angle at that cross-section, because the cross-section is a ring frame of fixed stiffness and the angle is the only thing the distortion changes. What it cannot say is the constant — how many N/mm² a milliradian makes at a given detail — which depends on the detail. So the figures carry the corner angle’s range, and lives are carried as ratios. A detail whose stress range is proportional to Δγ\Delta\gamma has, on Eurocode 3’s slope of three, a life proportional to Δγ−3\Delta\gamma^{-3}, and comparing two places along the same box needs nothing else.

What a tight frame protects, and how far

Where the plates feel the cross-frame, and where they never did. The range of the corner angle over one crossing of a 60 m box 4 m wide and 2.5 m deep with ring frames at 4 m and a cross-frame every 20 m, under a four-axle lorry of 440 kN at 1.5 m off its centre line, along the span. With no clearance it is 0.21 mrad at the cross-frames, 0.48 midway between them and at most 0.52; with 0.5 mm of clearance 0.36 at the frames and at most 0.53; with 1.0 mm of clearance 0.50 at the frames and at most 0.53; with no cross-frames at all, 0.51 and at most 0.53.
Fig. 1 The range of the corner angle over one crossing of the 440 kN lorry, along the span of the 60 m box with ring frames at 4 m and cross-frames at 20 and 40 m. With no clearance it is 0.21 mrad at the frames, 0.48 midway between them and 0.52 at worst; with 0.5 mm of clearance 0.36 at the frames; with a millimetre 0.50; with no cross-frames at all 0.51. The worst place, 0.52 to 0.53, is in the outer bays every time.

The tight box has a dent at each frame. The range of corner angle as the lorry passes is 0.21 mrad at the frame’s own cross-section, less than half the 0.48 midway between frames, and the dent is a few metres wide: the decay length of 6.6 m is the scale over which a point restraint on that foundation is felt, and the range is back to 0.39 at 5 m from a frame and 0.45 at 7 m. Outside the two frames, in the bays between each frame and its abutment, the range reaches 0.52. That is the box’s worst place and it is the worst place whatever is done to the frames, because a cross-frame at 20 m is two decay lengths and more from the plate at 10 m.

With a millimetre of clearance the dent fills in. At the frame the range is 0.50 mrad, almost the 0.51 the same section has with no frame at all, and the curve is very nearly the frameless box’s from end to end. Half a millimetre leaves a shallower dent, 0.36 at the frame. The box’s worst range rises only from 0.52 to 0.53, a gain of two per cent, because its worst place was never under a frame’s influence. A loose frame does not make the box worse where it was already worst; it makes it as bad as that almost everywhere.

A millimetre, and then nothing more to lose

A millimetre of clearance brings the frame's station up to the bay. Against the clearance in the cross-frames' diagonals, for a 60 m box 4 m wide and 2.5 m deep with ring frames at 4 m and a cross-frame every 20 m, under a four-axle lorry of 440 kN at 1.5 m off its centre line: the range of the corner angle over one crossing at a cross-frame, midway between frames, and at the box's worst place. With none, 0.21, 0.48 and 0.52 mrad; at 0.5 mm, 0.36, 0.51 and 0.53; at 1 mm, 0.50, 0.51 and 0.53; at 2 mm, 0.51, 0.51 and 0.53.
Fig. 2 Against the clearance in the cross-frames’ diagonals: the range of corner angle at a frame, midway between frames and at the box’s worst place. With none, 0.21, 0.48 and 0.52 mrad; at 0.5 mm, 0.36, 0.51 and 0.53; at 1 mm, 0.50, 0.51 and 0.53; at 2 mm, 0.51, 0.51 and 0.53. The frame’s station is all but at the bay’s range by a millimetre.

The frame’s station climbs steeply for the first millimetre and flat after it. That is the dead band at work. The lorry’s own distortion at the frame’s station, with no frame, is about half a milliradian, and a clearance of cc removes a band of c d/bhc\,d/bh — 0.47 mrad a millimetre on this box — before the frame begins to resist. So a frame with half a millimetre of clearance engages for the top half of the lorry’s swing and pulls the range down by roughly half of what a tight frame achieves; with a millimetre it engages only at the very top of the swing, and with 2 mm never. The midway plate, already outside the frame’s reach, moves from 0.48 to 0.51 — it was slightly helped by the frames through the foundation, and loses that too.

This is the same arithmetic that made the frame’s own diagonal go slack, and it carries the earlier essay’s conclusion over to the plates without any change of shape. What changes is the consequence. For the diagonal, clearance turns a working member into a resting one, and resting members live for ever. For the plate at the frame, clearance turns a protected place into an ordinary one.

How much life that is

The frame's protection is a few metres wide, and the clearance takes it away. The fatigue life of a detail whose stress follows the corner angle, along the span of a 60 m box 4 m wide and 2.5 m deep with ring frames at 4 m and a cross-frame every 20 m, under a four-axle lorry of 440 kN at 1.5 m off its centre line, over the life of the same detail at the tight box's worst place, on the slope of three. With no clearance a detail at a cross-frame lives 15.5 times as long, one midway between frames 1.26 times; with 1.0 mm of clearance 1.15 and 1.07, and the box's shortest life is 0.94 of the tight box's.
Fig. 3 The fatigue life of a detail whose stress follows the corner angle, along the span, over the life of the same detail at the tight box’s worst place, on the slope of three. With no clearance a detail at a frame lives 15.5 times as long and one midway between frames 1.26 times; with a millimetre of clearance, 1.15 and 1.07. The box’s shortest life is 0.94 of the tight box’s.

On Eurocode 3’s slope of three — the line the load that never came near failing anything draws for every welded detail — a range ratio is cubed. A detail at a tight frame sees 0.21/0.520.21/0.52 of the box’s worst range, and (0.52/0.21)3≈15(0.52/0.21)^3 \approx 15: the tight frame’s station has fifteen times the life of the same detail in the outer bay. With a millimetre of clearance the station’s range is 0.50, and the life ratio is (0.52/0.50)3≈1.15(0.52/0.50)^3 \approx 1.15. The detail at the frame has lost a factor of 15.5/1.1515.5/1.15, about thirteen, which is the factor of twelve the earlier essay guessed from the change of angle alone, now with the plate’s own range in it. Midway between frames the loss is a sixth (1.26 to 1.07), and at the box’s worst place six per cent (1 to 0.94).

The protection was always local. The life curve of the tight box is two narrow spikes at 20 m and 40 m standing on a floor that is nearly flat, and the spikes are about a decay length wide. A designer reading a fatigue check made at the frame’s station for the tight box would see an enormous margin; the same check made for a frame with clearance sees almost none. Whether that matters depends entirely on what stands at the station, and the figures so far have pretended it is the same detail as everywhere else.

A lorry light enough to miss the frame entirely

A light lorry finds no frame, a heavy one finds most of it. The range of the corner angle at a cross-frame over its range midway between frames, against the lorry's weight, for a 60 m box 4 m wide and 2.5 m deep with ring frames at 4 m and a cross-frame every 20 m, under a four-axle lorry at 1.5 m off its centre line, for clearances of 0.0, 0.5, 1.0 mm. With no clearance the ratio is 0.43 at every weight; with 1.0 mm it is 1.00 at 200 kN, 0.98 at 440 and 0.67 at 1,000.
Fig. 4 The range of corner angle at a cross-frame over its range midway between frames, against the lorry’s weight, for clearances of none, 0.5 and 1 mm. With no clearance the ratio is 0.43 at every weight; with a millimetre it is 1.00 at 200 kN — the frame might as well not be there — 0.98 at 440 and 0.67 at 1,000.

A tight frame is linear: double the lorry and the range at its station doubles, so the station’s range is 0.43 of the midway plate’s at any weight. A frame with clearance is not. Below the weight that takes up the clearance the frame is absent and the ratio is one; above it the frame catches the excess and the ratio falls, but slowly, because the dead band is subtracted from every event, not just the first. With a millimetre, a 200 kN lorry sees no frame at all, the 440 kN design lorry sees two per cent of one, and even a 1,000 kN abnormal load sees only enough to bring the station to two thirds of the midway range.

The lesson is about which lorries a plate counts. A fatigue spectrum is dominated by the commonest heavy vehicles, not the rarest, and those are exactly the ones for which the frame is absent. The abnormal load that finds the frame is too rare to matter in a damage sum and finds too little of it anyway. That is why the spectrum, next, looks like the single lorry.

The spectrum does not rescue the station

Over a spectrum of lorries the frame's station still catches up. The damage-equivalent range of the corner angle along the span of a 60 m box 4 m wide and 2.5 m deep with ring frames at 4 m and a cross-frame every 20 m, over a spectrum of five four-axle lorries from 200 to 490 kN, on the slope of three. With no clearance 0.21 mrad at the cross-frames and 0.47 midway; with 1.0 mm of clearance 0.47 and 0.50, the frame's station 2.29 times its tight value.
Fig. 5 The damage-equivalent range of corner angle along the span over a spectrum of five four-axle lorries from 200 to 490 kN, on the slope of three. With no clearance 0.21 mrad at the frames and 0.47 midway; with a millimetre of clearance 0.47 and 0.50, the frame’s station 2.29 times its tight value.

The spectrum is the earlier essay’s: five lorries from 200 to 490 kN, half of them the heaviest. Each is run across the box, the range at every station cubed and weighted by its share, and the cube root taken. For a tight frame this is just the single lorry scaled, since everything is linear; the station sits at 0.21 against 0.47 midway. With a millimetre of clearance only the two heaviest lorries reach the frame at all, and they reach it by a little, so the station’s equivalent range is 0.47 against 0.50 midway: 2.29 times its tight value. Cubed, that is a twelvefold loss of life at the station under the spectrum, essentially the single lorry’s thirteen.

The earlier essay found that the same spectrum lowers the frame’s diagonal damage-equivalent range from 18.9 N/mm² to 2.3 at a millimetre, which read as a reason to prefer clearance. Both findings are the same fact seen from the two sides of the bolt. The energy that does not go into the diagonal goes into the plates, because the distortion is set by the lorry and the box, and a frame that will not resist it leaves all of it to the walls.

The detail that stands under the frame

The clearance moves the critical detail to the frame only if the frame's is worse. The fatigue life of a detail at a cross-frame of a 60 m box 4 m wide and 2.5 m deep with ring frames at 4 m and a cross-frame every 20 m, under a four-axle lorry of 440 kN at 1.5 m off its centre line over the life of the shortest-lived plain detail of the box away from the frames, against the clearance, for a frame detail one, two and three categories worse than the plain one. With no clearance, 10.87, 7.59, 5.33; at 1 mm, 0.85, 0.59, 0.42; at 2 mm, 0.80, 0.56, 0.39. Below one the frame's detail governs the box.
Fig. 6 The fatigue life of a detail at a cross-frame over the life of the shortest-lived plain detail of the box away from the frames, against the clearance, for a frame detail one, two and three categories worse than the plain one. With no clearance, 10.87, 7.59 and 5.33; at 1 mm, 0.85, 0.59 and 0.42; at 2 mm, 0.80, 0.56 and 0.39. Below one, the frame’s detail governs the box.

The details at a cross-frame are not the details of plain plate. The frame’s gussets are welded to the walls and to the bottom flange, and a gusset’s weld toe or the end of a fillet-welded attachment is in Eurocode 3’s tables several categories below a longitudinal stiffener on a plain wall. The steps are a factor of about 1.12 in strength each — 80, 71, 63, 56 — so one category is 1/1.123=0.701/1.12^3 = 0.70 of the life at the same range and three categories are 0.3430.343. That is a thing a tight frame paid for in advance: its own station’s range is so low that a detail three categories worse still lives 5.33 times as long as the box’s shortest plain detail. Nobody checking the tight box would think the gusset was the critical detail, and they would be right.

With a millimetre of clearance the same gusset lives 0.42 of the plain detail’s life. The critical detail of the box has moved, from the plate in the outer bay to the gusset under the frame, and it has moved because of a tolerance on a hole that no drawing of the box shows. The figure draws the crossover. A frame detail one category worse than the plain plate crosses to governing between 0.5 and 1 mm; three categories worse crosses before half a millimetre. Two millimetres, the standard oversize, is past the crossover for every one.

So the answer to the earlier essay’s question is both of its alternatives at once. The plate midway between frames barely noticed the frame, and still barely notices it with clearance. The plate at the frame loses a factor of about thirteen. Whether that moves the critical location depends on what is welded there, and what is welded there is the frame’s own connection, which is nearly always the worse detail. The tolerance does not move the worst stress; it moves the worst stress onto the worst detail.

The range at the frame, by hand

The whole result can be had from three numbers without the series. The lorry distorts the box at the frame’s station by about γ0=0.5\gamma_0 = 0.5 mrad of range with no frame. A tight frame of stiffness KfK_f on a foundation of stiffness KdK_d and decay length λ\lambda reduces the local range by the factor of a point spring on a beam on an elastic foundation,

γfγ0=11+Kf/(2Kdλ),\frac{\gamma_f}{\gamma_0} = \frac{1}{1 + K_f/(2K_d\lambda)},

and the tight frame’s own ratio of 0.43 in the weight figure fixes Kf/(2Kdλ)K_f/(2K_d\lambda) at about 1.33 on this box. A clearance with dead band γg\gamma_g subtracts γg\gamma_g from what the spring sees, so the frame’s station sees roughly

γf≈γ0−Kf/(2Kdλ)1+Kf/(2Kdλ) (γ0−γg)  for γ0>γg,\gamma_f \approx \gamma_0 - \frac{K_f/(2K_d\lambda)}{1 + K_f/(2K_d\lambda)}\,(\gamma_0 - \gamma_g)\ \text{ for } \gamma_0 > \gamma_g,

and at γg=0.47\gamma_g = 0.47 against γ0=0.51\gamma_0 = 0.51 that is 0.51−0.57×0.04=0.490.51 - 0.57 \times 0.04 = 0.49, within a hundredth of the 0.50 the full calculation gives. (The range is a crossing’s swing rather than one peak, so this is a rough reading, not a derivation; it lands where it should because the lorry’s angle at the station barely changes sign.) The cube does the rest. The hand version shows what the figures show: the frame’s protection is proportional to how far the lorry overshoots the dead band, and on a box stiffened by ring frames the lorry overshoots it by almost nothing.

That also says when the result would be different. A box without ring frames distorts several times as much under the same lorry, so a millimetre of clearance is a small part of its γ0\gamma_0 and the frame still protects its station; the earlier essay found exactly that for the diagonal, which kept 36 of its 42 N/mm² through 2 mm on a box with no rings. The ring frames that make the box good are what make the cross-frame’s tolerance decisive, which is the diaphragm that is a few angles and the stiff frame among soft ones arriving at the plates by a different road.

What a fatigue check should read

The practical consequence is a choice between two remedies and a warning about a third. The first remedy is to make the frame tight: fitted bolts or preloaded friction connections, which behave as no clearance up to their slip load, and the earlier essay’s argument about the hole made bigger so the steel would fit applies to them as it does to any slip-resistant joint. The second is to check the frame’s own details for the bay’s range rather than the frame’s, which is what a box with loose frames actually gives them. Either is honest. The warning is about mixing them: a fatigue check of the gussets that takes the tight frame’s low range and a connection specification that allows normal clearance holes is checking a detail against a structure that is not the one built.

There is a third option that sounds attractive and does not work: specify a smaller clearance. Half a millimetre still leaves the station at 0.36 mrad against 0.21 tight — a life loss of five — and a millimetre is the whole loss. The dead band has to be smaller than the lorry’s overshoot, and on this box the lorry’s overshoot is a few hundredths of a milliradian, which is a few hundredths of a millimetre in a hole. No ordinary fit is that tight; only preload or fitted bolts are.

What the angle alone leaves out

Everything here takes a detail’s stress as the corner angle times a constant. That is right for distortional stresses and leaves two things out. The first is the box’s ordinary bending and torsion, which add a stress range at every detail that does not depend on the frames at all; on a real box it can be larger than the distortional part, and then the ratios of life here are diluted toward one. The second is the frame’s own local stresses where its diagonals land — when a tight frame works it pushes on its gusset with the diagonal’s force, which is a stress a loose frame does not apply. Both would move numbers. Neither moves the sign of the result: the frame’s station gains distortional range with clearance, and the frame’s details are the ones that feel it.

The model also treats the clearance as the same in every bolt and fixed for ever. Holes are drilled to a tolerance, bolts sit wherever they were put, and a frame may be tight in one diagonal and loose in the other. A frame that has been pushed hard once may have its bolts come into bearing and stay there, which is the history the braces with slack in their bolts traced in a brace. A box is also a structure of many frames, and the figures have two; with more frames the protected spikes are more numerous and each still a decay length wide, so the share of the box’s plate that a loose fitting un-protects grows with the number of frames while the loss at each stays the same.

And the life ratios are on the slope of three throughout. Below Eurocode 3’s constant-amplitude limit a detail under a spectrum moves to the slope of five, and a station whose ranges sat mostly below the knee when tight and mostly above it when loose loses more than the cube says — the tight frame’s spike is taller and its collapse steeper. That makes the result stronger, not weaker, and it is why the cycles that do not count is the right companion to this page: a clearance can move a detail from the side of the knee where most cycles do nothing to the side where every one is counted.

Still open: the plate between two loose frames that are loose differently

Both frames here have the same clearance, so the box is symmetric and so is its loss. A real box has frames with clearances that differ by the fitter’s luck, and a box whose frame at 20 m is tight and whose frame at 40 m has a millimetre is no longer a box with two frames but one with a single frame placed off-centre. The distortion then redistributes along the span: the tight frame takes more, and the plate around it may find a range it did not have when both were tight, while the loose frame’s station takes the bay’s. Whether a box with one tight frame and one loose one has a worst detail at the tight frame’s gusset — which would mean that tightening one frame at an inspection can move the critical detail rather than relieve it — or whether each frame’s station keeps the life its own fit gives it, is the question that a box with one diaphragm that is nearly none and another that is a real one puts to the plates around them.