Concept

Diaphragm — where it appears

A floor plate working in its own plane as a deep beam, whose stiffness relative to the walls it spans between decides how a lateral load is shared. Whether it is rigid or flexible is a comparison between its own in-plane stiffness and the walls it spans between, and the answer decides whether load is shared by stiffness or by tributary area.

Named by 17 essays across 5 fields — each of them below, with the objects they name alongside it.

Two centres, and the distance between them is a torque. A storey 30 by 18 m with its walls drawn heavy, pushed in one direction by 1000 kN. The force acts through the centre of mass and the storey turns about the centre of rigidity — the stiffness-weighted centroid of the walls, at x = 15.0 m — and the distance between the two is an eccentricity of 0.00 m before the 5% that has to be assumed anyway. The table below the plan splits each wall's force into its direct share and its torsional one. Torsion relieves the walls near the centre of rigidity and loads the far ones, so the wall in trouble is not the wall carrying the most: west wall is asked for 8% more than its direct share, and the walls at right angles to the push carry 19 kN each with nothing applied along them at all.

The corner that moves most

A lateral force is shared out in proportion to stiffness only if it passes through the centre of rigidity, which is not the centre of the plan and not the centre of mass. The distance between the two is a torque, and the wall that pays for it is the one furthest away and carrying least.

structures · Plan torsion
Whether the floor shares the load out by stiffness or by area. The share of a uniform storey force taken by each of three equally stiff walls, against the stiffness of the floor plate that spans between them. A plate far stiffer than the walls translates almost rigidly, every wall deflects the same and the share is the ratio of stiffnesses — 60% to the middle wall here, the same as everyone else. A plate far softer than the walls behaves as a continuous beam over them and the middle wall takes 33%. Neither end is the tributary-area answer of 50%, which assumes a plate that is both soft and discontinuous over the wall, and which nothing here ever reaches.

The floor is a beam lying down

A floor plate spans horizontally between the walls that resist a lateral load, carries a distributed inertia load, and has chords, a web and a span-to-depth ratio like any other beam. Its stiffness decides whether the walls share the load by their stiffness or by the area of floor nearest them — and the familiar tributary answer turns out to be neither limit.

structures · Diaphragm
An eccentric load is three load cases, and only two of them are checked. A line load of 40 N/mm at 1.5 m from the axis of a 3.0 by 2.0 m box, replaced by the three cases it is equivalent to. Bending is the load on the axis. The torque 60 kNm per metre then splits into a set of edge forces that drives Bredt's shear flow and distorts nothing, and a set with the flange forces reversed — 10.0 kN/m up one web and down the other, 15.0 kN/m across the flanges — which carries no torque at all and squashes the rectangle into the rhombus drawn behind it. Its generalised load is exactly half the torque, so a box girder spends half of an eccentric load's torsion on changing its own shape, and no torsion calculation contains that half.

The section that will not keep its shape

A box girder is closed, so torsion costs it almost nothing. What an eccentric load actually does to it is something a torsion calculation contains no term for — the rectangle becomes a parallelogram, in its own plane, along the whole length of the span.

sections · Box distortion
The web down the middle carries no torsion at all. A 2-cell box 3.0 m wide and 1.5 m deep under 4000 kNm of torque. Statics gives one equation, T = 2 Σ q_i A_i, and there are 2 unknown flows — so the section is torsionally redundant and the missing statements are that every cell twists by the same amount. Solving that system gives 444.4 and 444.4 N/mm in the cells, so the internal web carries 0.00 N/mm — 0.00 per cent of the outer wall's. J is 2.3679e+12 mm⁴ against 2.3679e+12 for the same outline with no internal web at all, a ratio of 1.000000. The same walls slit open would give 7.413e+10, so closure is worth 32 times and the internal web is worth what the ratio says.

Two cells, one equation, and a web with nothing in it

Bredt's formula answers a single closed cell because a single closed cell has one unknown and one equation. Put a web down the middle and there are two unknowns and still one equation — and the answer, when the missing statement is supplied, is that the new web carries exactly nothing.

sections · Multicell torsion
The distortion runs the length of the span, and a diaphragm stops it. Longitudinal stress at a corner of the box from distortional warping, along a 60 m span carrying 45 N/mm at 2.0 m off the axis. With no interior diaphragm it peaks at 73 N/mm², which is 83 per cent of the bending stress the girder was designed for. Two interior diaphragms take it to 18. The governing length is Winkler's: the distortion decays over 23.6 m, so a diaphragm helps its neighbours only if it is closer than that, and past it the spacing stops mattering.

One diaphragm is nearly none

A box girder's distortion decays over a length the section decides, and on a sixty-metre span that length is twenty-four metres. So a single diaphragm at midspan sits further from each end than the distortion can reach and removes a third of the problem; three diaphragms remove nine tenths. The spacing rule is not span over five — it is a property of the plates.

sections · Box distortion
Two webs of one box, carrying different amounts of the same load. The equivalent stress on each web of a 3.0 × 2.0 m box along the half span, under 40 N/mm at an eccentricity of 1500 mm, with the bending stress alone drawn for comparison. The two webs carry the same bending and opposite torsion, so one gets the sum and the other the difference: at the quarter point the loaded web is at 116 N/mm² and the far web at 11, a ratio of 10.9. A check made on the section rather than on the wall reports the average of two numbers that differ by that much.

Three actions on one web

A load applied off the centreline of a box girder is three actions at once, and every textbook decomposes it into them. What the decomposition does not say is that all three land on the same piece of plate — added on one web and subtracted on the other, so the two walls of one section differ by a factor of ten.

sections · Multicell torsion
Where two buildings touch, and what is there when they do. Closure between an 8-storey building 24 m tall and a 4-storey one 15 m tall, drawn against height, with the 50 mm gap between them. The two swaying out of phase close on each other more the higher up they are, so they first touch at 7.6 m and are in contact above it. The dots are the taller building's floors: its storeys are 3.00 m and the other's are 3.75, so two of them arrive part way up a column rather than at a slab. A blow at mid-height of a column asks it for a shear of half the impact and an end moment of Fh/8, neither of which is a demand any part of the design contains.

The floor that arrives at a column

The gap between two buildings is computed from their roof displacements, which is where each of them moves most. It is not where they touch, and it is not what is there when they do — a slab edge meeting a column part way up its height is a different event from two slabs meeting, and it is the one that appears in the photographs.

dynamics · Pounding
One quantity, three names. The middle braced bay's share of the storey force (solid) and one end bay's (dashed), for a 48 by 12 m plate, 200 mm of concrete, spanning two 24 m bays between three braced bays of 100,000 kN/m each, under 40 kN/m, against a factor on the plate's stiffness as built, on a logarithmic scale. The share moves continuously from 61 per cent, a continuous plate on unyielding supports, to 33 per cent, the rigid plate. Left of 0.02 (shaded) ASCE 7 calls the plate flexible and assigns tributary shares, 50 per cent to the middle; the plate there actually gives it 59 per cent at the boundary. Right of 1.54 (shaded) EN 1998-1 calls it rigid and assigns stiffness shares, 33 per cent; at that boundary the plate gives 37. The plate as built, factor 1, gives 38 per cent to the middle and 31 to each end.

Rigid by one code and not by the other

A floor plate between shear walls shares its storey force out in proportions that move continuously with its stiffness, from a continuous beam's to a rigid body's. The codes put it in one of two boxes and use a different model in each. ASCE 7 and EN 1998-1 draw their boxes' edges a hundred times apart in plate stiffness, each at a point where its own licensed model already misstates the middle wall by about a tenth — and an ordinary 200 mm slab sits in the gap between them.

structures · Diaphragm
The slab carries what the collector does not, beside the bay. The plate's shear flow just beside the same brace line, along it: the rule's uniform 40 kN/m (dashed); with a 150 mm concrete slab (solid), concentrated beside the bay — 132 kN/m on average over the bay's 6 m, 3.3 times the rule's, with peaks at the bay's ends that grow as the mesh is refined, because a stiff support ending in a plate is a stress singularity — and little elsewhere; with a steel deck of shear stiffness 10,000 kN/m (dotted), close to uniform. Each curve adds up to the line's 960 kN.

The collector the slab does not need

A floor delivers its storey force to a short braced bay through a collector, a member along the brace line that gathers the floor's shear and carries it to the bay. The rule that sizes it assumes the floor hands over its shear uniformly along the whole line. A concrete slab does not: it is so stiff in shear that it sends most of its load straight into the bay, the collector carries about a quarter of the rule's force, and the slab beside the bay works at more than three times the rule's shear. A steel deck is the other way round. The rule is right for one floor, and safe for the other only while the slab stays uncracked.

structures · Diaphragm
A building that crosses the trough at an angle stands on a warped surface. Plan of a 30 × 12 m building 10 m high, its walls 300 mm thick, over a trough 30 mm deep with its inflection 15 m from the tunnel's axis, its long axis 45° from square across the tunnel. The lines are the greenfield trough's settlement contours, 5, 10, 15, 20, 25 mm, parallel to the tunnel's axis (dashed). The corners settle A 27.4, B 18.4, C 27.4, D 18.4 mm, so they do not lie in a plane: A and C together settle 18.1 mm more than B and D. A building spanning square across the trough has no such warp, and one lying along it has none either; between the two, the trough twists the building as well as bending it.

The building the trough twists

A building that crosses a tunnel's settlement trough at an angle stands on ground that is warped as well as sagged. Its four corners do not settle into a plane, and beyond about twenty degrees of skew the warp is larger than the sag. Whether the building follows that warp or resists it depends on a property its bending never needed — whether its walls and floors close into a tube — and the same walls, closed or open, differ a thousandfold in their stiffness against it.

deflection · Differential settlement
A stiff floor shares by stiffness, a soft one by distance. The share of a brace line's force that reaches its soft bay, against the other bay's stiffness over the soft bay's on a logarithmic scale, for a 48 by 24 m floor carrying 40 kN per metre of span, each brace line 960 kN, with a 6 m braced bay of 200 kN/mm at one end of each line and a 6 m bay 10 times as stiff — for three floors (dashed: a rigid floor, which shares by stiffness, and the tributary half). With the other bay ten times as stiff the rigid floor gives the soft bay 9%; the concrete slab 16%, the cracked slab 30% and the steel deck 37%.

The floor that feeds two bays

A brace line with a braced frame at one end and a core wall ten times as stiff at the other is analysed one of two ways. As a rigid floor, which shares the line's force between the bays by their stiffness and gives the frame 9%. Or as a flexible floor, which gives each bay the half of the line nearest it, 50%. Solved as a membrane, an uncracked concrete slab gives the frame 16%, the same slab cracked 30%, and a steel deck 37%. The floor does not send its shear to the nearer bay; a stiff floor sends it to the stiffer one. The frame's design force depends on which state the floor is in when the storey force arrives, by more than a factor of two.

structures · Diaphragm
Rigid enough long before it is a plate. A box 4.0 m wide and 2.5 m deep on a 60 m span, 45 kN/m at 2.0 m off its axis, with three diaphragms, each diaphragm of racking stiffness K, against K over the girder's own stiffness against a point distortional load, 15.0 × 10⁹ N·mm/rad: the largest warping stress (solid) and the largest distortion, which drives the walls' transverse bending (dashed), each over its value with rigid diaphragms. At ten times the girder's stiffness the warping stress is 1.05 of the rigid value and the distortion 8.37 times it; at a hundred, 0.89 and 1.50; at a thousand, 0.99 and 1.05. Marked: a cross-frame of two 1,000 mm² diagonals (26 times) and a 10 mm plate (524 times).

The diaphragm that is a few angles

A box girder's diaphragm holds its section square against the distortion an eccentric load drives. It does not have to be rigid; it has to be stiff against the girder's own resistance to a point racking load, which is small — twice the section's frame stiffness times its decay length. A cross-frame of two 1,000 mm² diagonals is twenty-six times that and holds the warping stress at the rigid value, while a 10 mm plate is five hundred times it. The cross-frame lets the section rack three times as far as a plate, which leaves the walls bending at 5 N/mm² instead of 1.5, against 275 with no diaphragm at all. And its diagonals carry nearly a rigid diaphragm's force whatever their stiffness, so it is sized for strength.

sections · Box distortion
Ring frames close together are a continuous foundation. The corner-angle change along a 60.0 m box 4.0 m wide and 2.5 m deep, its top flange an orthotropic deck of 14 mm plate, its webs 14 mm and its bottom flange 20 mm, under 45 kN/m at 2.0 m from its centre line, in milliradians, with ring frames whose crossbeam has a second moment of 1.7 × 10⁹ mm⁴ every 4.0 m and every 12.0 m (solid), and each row smeared into a continuous foundation of the same stiffness per metre (dashed). At 4.0 m the two are indistinguishable, 1.12 and 1.12 at the worst point; at 12.0 m the box distorts between its frames, to 3.45 against 3.33. Without any frames the same deck distorts 145.

The deck whose frame is its crossbeams

A steel box girder resists distortion as a beam on an elastic foundation, the foundation being its walls' transverse bending. When the top flange is an orthotropic deck, that foundation is almost absent between the crossbeams and concentrated at them, so the box sits on a row of springs, not a bed. Smeared into a bed, the springs give the right answer to within a few per cent as long as they are closer together than the bed's own decay length — and the rule holds for every crossbeam stiffness on one curve. Past that spacing the frames act as separate diaphragms and the warping stress between them doubles.

sections · Box distortion
Whether the cross-frames' spacing matters depends on the crossbeams between them. For the 60.0 m orthotropic box 4.0 m wide and 2.5 m deep under 45 kN/m at 2.0 m from its centre line: the largest distortional warping stress against the spacing of cross-frames of two 1,900 mm² diagonals, with nothing between them (dashed), with open tee crossbeams every 4.0 m (light) and with ring frames every 4.0 m (solid); dotted, the ring frames alone, 4.1 N/mm². At 8 m, 3.8, 3.8 and 3.1 N/mm²; at 20 m, 21.8, 21.7 and 7.1; at 30 m, 60.8, 59.2 and 7.3.

The stiff frame among soft ones

A steel box girder with an orthotropic deck is held in shape by a frame at every crossbeam, and its designers usually add a stiffer frame — a pair of diagonals across the box — at every few crossbeams as well. Whether the soft frames between can be left to do the work depends on one length: how far a distortion reaches along a box held by the soft frames alone. Ring frames welded into the webs and bottom flange hold it to six and a half metres, and then cross-frames twenty metres apart barely change the distortion and add a peak of warping stress at each one, where a stiff frame grips a box that was distorting gently. Crossbeams that are only tees under the deck reach twenty-one metres, and then the box between the cross-frames distorts as if the crossbeams were not there.

sections · Box distortion
A floor that shears lowers the storey's buckling load before the core does. The buckling factor of a storey of eleven lines of leaning columns, ten bays, each column carrying 3,000 kN over 3.6 m and built a three-hundredth out of plumb, held by a floor to a core sized for a buckling factor of 4.0 were the floor rigid, against the floor's shear stiffness per bay as a multiple of a column's sway softening P/h, logarithmic, with the core at one end, in the middle, or split between both ends; dotted, the rigid floor's 4.0. At 100 times the factor is 1.52, 2.80 and 3.02; at 1,000 times, 3.49, 3.84 and 3.88; a concrete slab is several thousand times.

The floor the columns lean on

A storey of pin-ended columns, every one a little out of plumb, leans on its floor, and the floor leans on a core. Count the floor as rigid and the core needs the sum of the columns' demands. A floor that shears in its own plane is a brace in series with the core, and the far columns lean on it before their push arrives. With a floor a hundred times stiffer per bay than a column's own sway softening, the storey's buckling factor falls from 4.0 to 1.5 and the core is asked for twice as much.

stability · Effective length
A clearance is a weight below which the frame does not exist. The stress range in a cross-frame diagonal of a 60 m box 4 m wide and 2.5 m deep with ring frames at 4 m and a cross-frame every 20 m, under a four-axle lorry at 1.5 m off its centre line, against the lorry's weight, for clearances of 0.0, 0.5, 1.0, 2.0 mm. At 440 kN, 19.3, 9.9, 0.7, 0.0 N/mm². With 0.5 mm the diagonal first carries anything by 250 kN; With 1.0 mm the diagonal first carries anything by 450 kN; With 2.0 mm the diagonal first carries anything by 850 kN.

The frame that waits for a heavy lorry

A cross-frame in a steel box is drawn as a spring, and most are bolted through clearance holes, so the spring does nothing until the box has distorted far enough to take up the hole. Among ring frames, where the box barely distorts, a millimetre of clearance is about the whole of what a 440 kN lorry can ask. The frame is then a piece of steel that a heavier lorry occasionally touches, and its fatigue life, its hard point and its share of the distortion all belong to a structure that is not the one calculated. Take the ring frames away and the same millimetre barely matters.

sections · Box distortion
Where the plates feel the cross-frame, and where they never did. The range of the corner angle over one crossing of a 60 m box 4 m wide and 2.5 m deep with ring frames at 4 m and a cross-frame every 20 m, under a four-axle lorry of 440 kN at 1.5 m off its centre line, along the span. With no clearance it is 0.21 mrad at the cross-frames, 0.48 midway between them and at most 0.52; with 0.5 mm of clearance 0.36 at the frames and at most 0.53; with 1.0 mm of clearance 0.50 at the frames and at most 0.53; with no cross-frames at all, 0.51 and at most 0.53.

The plate the loose frame stops protecting

A cross-frame bolted through clearance holes does nothing until a lorry has distorted the box far enough to take up the hole, and among ring frames a millimetre is nearly the whole distortion a lorry produces. What that costs is not the frame's own life but the plates' around it. A tight frame holds the corner angle's range to 0.21 mrad over a few metres either side of itself; a millimetre of clearance lets it rise to 0.50, and a detail there loses a factor of thirteen in fatigue life. The box's worst place does not move, because it was never at the frame. The critical detail moves only if the frame's own detail is a worse category than the plain plate's, which it usually is.

sections · Box distortion

Named alongside it

The objects these essays reach for when they reach for this one.

Box girderDistortionWarpingShear flowElastic foundationLoad pathStiffnessLoad sharingFatigueLateral systemShear wallTorsion

All concepts