Diaphragm — where it appears
Named by 17 essays across 5 fields — each of them below, with the objects they name alongside it.
The corner that moves most
A lateral force is shared out in proportion to stiffness only if it passes through the centre of rigidity, which is not the centre of the plan and not the centre of mass. The distance between the two is a torque, and the wall that pays for it is the one furthest away and carrying least.
The floor is a beam lying down
A floor plate spans horizontally between the walls that resist a lateral load, carries a distributed inertia load, and has chords, a web and a span-to-depth ratio like any other beam. Its stiffness decides whether the walls share the load by their stiffness or by the area of floor nearest them — and the familiar tributary answer turns out to be neither limit.
The section that will not keep its shape
A box girder is closed, so torsion costs it almost nothing. What an eccentric load actually does to it is something a torsion calculation contains no term for — the rectangle becomes a parallelogram, in its own plane, along the whole length of the span.
Two cells, one equation, and a web with nothing in it
Bredt's formula answers a single closed cell because a single closed cell has one unknown and one equation. Put a web down the middle and there are two unknowns and still one equation — and the answer, when the missing statement is supplied, is that the new web carries exactly nothing.
One diaphragm is nearly none
A box girder's distortion decays over a length the section decides, and on a sixty-metre span that length is twenty-four metres. So a single diaphragm at midspan sits further from each end than the distortion can reach and removes a third of the problem; three diaphragms remove nine tenths. The spacing rule is not span over five — it is a property of the plates.
Three actions on one web
A load applied off the centreline of a box girder is three actions at once, and every textbook decomposes it into them. What the decomposition does not say is that all three land on the same piece of plate — added on one web and subtracted on the other, so the two walls of one section differ by a factor of ten.
The floor that arrives at a column
The gap between two buildings is computed from their roof displacements, which is where each of them moves most. It is not where they touch, and it is not what is there when they do — a slab edge meeting a column part way up its height is a different event from two slabs meeting, and it is the one that appears in the photographs.
Rigid by one code and not by the other
A floor plate between shear walls shares its storey force out in proportions that move continuously with its stiffness, from a continuous beam's to a rigid body's. The codes put it in one of two boxes and use a different model in each. ASCE 7 and EN 1998-1 draw their boxes' edges a hundred times apart in plate stiffness, each at a point where its own licensed model already misstates the middle wall by about a tenth — and an ordinary 200 mm slab sits in the gap between them.
The collector the slab does not need
A floor delivers its storey force to a short braced bay through a collector, a member along the brace line that gathers the floor's shear and carries it to the bay. The rule that sizes it assumes the floor hands over its shear uniformly along the whole line. A concrete slab does not: it is so stiff in shear that it sends most of its load straight into the bay, the collector carries about a quarter of the rule's force, and the slab beside the bay works at more than three times the rule's shear. A steel deck is the other way round. The rule is right for one floor, and safe for the other only while the slab stays uncracked.
The building the trough twists
A building that crosses a tunnel's settlement trough at an angle stands on ground that is warped as well as sagged. Its four corners do not settle into a plane, and beyond about twenty degrees of skew the warp is larger than the sag. Whether the building follows that warp or resists it depends on a property its bending never needed — whether its walls and floors close into a tube — and the same walls, closed or open, differ a thousandfold in their stiffness against it.
The floor that feeds two bays
A brace line with a braced frame at one end and a core wall ten times as stiff at the other is analysed one of two ways. As a rigid floor, which shares the line's force between the bays by their stiffness and gives the frame 9%. Or as a flexible floor, which gives each bay the half of the line nearest it, 50%. Solved as a membrane, an uncracked concrete slab gives the frame 16%, the same slab cracked 30%, and a steel deck 37%. The floor does not send its shear to the nearer bay; a stiff floor sends it to the stiffer one. The frame's design force depends on which state the floor is in when the storey force arrives, by more than a factor of two.
The diaphragm that is a few angles
A box girder's diaphragm holds its section square against the distortion an eccentric load drives. It does not have to be rigid; it has to be stiff against the girder's own resistance to a point racking load, which is small — twice the section's frame stiffness times its decay length. A cross-frame of two 1,000 mm² diagonals is twenty-six times that and holds the warping stress at the rigid value, while a 10 mm plate is five hundred times it. The cross-frame lets the section rack three times as far as a plate, which leaves the walls bending at 5 N/mm² instead of 1.5, against 275 with no diaphragm at all. And its diagonals carry nearly a rigid diaphragm's force whatever their stiffness, so it is sized for strength.
The deck whose frame is its crossbeams
A steel box girder resists distortion as a beam on an elastic foundation, the foundation being its walls' transverse bending. When the top flange is an orthotropic deck, that foundation is almost absent between the crossbeams and concentrated at them, so the box sits on a row of springs, not a bed. Smeared into a bed, the springs give the right answer to within a few per cent as long as they are closer together than the bed's own decay length — and the rule holds for every crossbeam stiffness on one curve. Past that spacing the frames act as separate diaphragms and the warping stress between them doubles.
The stiff frame among soft ones
A steel box girder with an orthotropic deck is held in shape by a frame at every crossbeam, and its designers usually add a stiffer frame — a pair of diagonals across the box — at every few crossbeams as well. Whether the soft frames between can be left to do the work depends on one length: how far a distortion reaches along a box held by the soft frames alone. Ring frames welded into the webs and bottom flange hold it to six and a half metres, and then cross-frames twenty metres apart barely change the distortion and add a peak of warping stress at each one, where a stiff frame grips a box that was distorting gently. Crossbeams that are only tees under the deck reach twenty-one metres, and then the box between the cross-frames distorts as if the crossbeams were not there.
The floor the columns lean on
A storey of pin-ended columns, every one a little out of plumb, leans on its floor, and the floor leans on a core. Count the floor as rigid and the core needs the sum of the columns' demands. A floor that shears in its own plane is a brace in series with the core, and the far columns lean on it before their push arrives. With a floor a hundred times stiffer per bay than a column's own sway softening, the storey's buckling factor falls from 4.0 to 1.5 and the core is asked for twice as much.
The frame that waits for a heavy lorry
A cross-frame in a steel box is drawn as a spring, and most are bolted through clearance holes, so the spring does nothing until the box has distorted far enough to take up the hole. Among ring frames, where the box barely distorts, a millimetre of clearance is about the whole of what a 440 kN lorry can ask. The frame is then a piece of steel that a heavier lorry occasionally touches, and its fatigue life, its hard point and its share of the distortion all belong to a structure that is not the one calculated. Take the ring frames away and the same millimetre barely matters.
The plate the loose frame stops protecting
A cross-frame bolted through clearance holes does nothing until a lorry has distorted the box far enough to take up the hole, and among ring frames a millimetre is nearly the whole distortion a lorry produces. What that costs is not the frame's own life but the plates' around it. A tight frame holds the corner angle's range to 0.21 mrad over a few metres either side of itself; a millimetre of clearance lets it rise to 0.50, and a detail there loses a factor of thirteen in fatigue life. The box's worst place does not move, because it was never at the frame. The critical detail moves only if the frame's own detail is a worse category than the plain plate's, which it usually is.
Named alongside it
The objects these essays reach for when they reach for this one.
Box girderDistortionWarpingShear flowElastic foundationLoad pathStiffnessLoad sharingFatigueLateral systemShear wallTorsion