The push the shared joints were waiting for
Assumes Answering one question without solving the rest, The forces that are there with nothing applied and One support too many, and what it costs to know.
The redundancy only the sun can find, following the cut that needs a joint first from a tower into a bridge, took a K-braced girder whose K’s open toward mid-span from both ends, so that at the centre two K’s meet at one joint and four diagonals arrive there. The count said the girder had one unknown too many, and the forces it could hold with nothing on it — its one self-stress state — lived entirely in the two middle panels. A vertical load called on that state only where the load entered one of its members, so the cut that answers one question, made as if each K had a joint of its own, was exact for most loads and within a tenth for the rest. What did call on the state was a misfit or a warm chord, a girder built to the wrong length or heated unevenly: an action that changes the members’ lengths without being a load.
The essay ended with girders where more than two K’s meet: a lattice whose pattern turns at more than one vertical, or double K’s stacked in a panel, or the corner of a space frame where K’s from two faces meet on one leg, which would have to be counted with three equations at every joint rather than two. Its questions were whether each shared joint adds exactly one state, whether the states stay out of each other’s way and out of bending’s, and whether a load can reach them only through their own members. Two of those have plain answers. The third has an answer with an exception, and the exception is a load every building girder of this kind may carry.
A girder can turn its K’s anywhere
The girder is the same shape: eight panels of 3 m, 3 m deep, web members of 2,000 mm² and chords of 6,000. Each panel’s K opens either toward the vertical on its right or toward the vertical on its left; its two diagonals run from the chord joints at one end of the panel to a joint at mid-depth on the vertical at the other. A pattern of eight letters, R or L, describes the whole girder. RRRRLLLL is the earlier essay’s girder, its K’s opening toward mid-span from both ends. Wherever an R stands immediately left of an L, the two K’s point at the same vertical, and that vertical’s mid-depth joint receives four diagonals.
Three patterns are drawn. Turned once, RRRRLLLL, the girder has one shared joint and one state, the earlier essay’s. Turned three times, RRLLRRLL, it has two shared joints, over the second and sixth verticals, and two states, each in the two panels either side of its joint and each a copy of the first. Turned at every panel, RLRLRLRL, it has four shared joints and four states, packed so tightly that neighbouring states meet: each pair shares the full-height vertical between them, where no K points and the vertical runs unbroken from chord to chord.
Each state has the same form. The four diagonals at its joint are in tension, pulling that joint four ways at once; the chord members over its two panels are in compression, holding the far ends of those diagonals apart; and the verticals at the outer ends of its two panels close the loop. In the turned-once girder those outer verticals are the upper and lower halves of verticals that have joints of their own at mid-depth. In the alternating girder they are full-height verticals, and each is the outer member of two states at once.
Exactly as many states as turns
Counting predicts one state for each shared joint. A girder of this kind with no shared joint is determinate: every K has its own mid-depth joint and every panel adds as many members as equations. A shared joint means one K fewer mid-depth joints, so two equations fewer, and one member fewer, the vertical that would have been split there. One unknown is left over. The count cannot say whether that unknown is a self-stress state or whether, somewhere else in the frame, a mechanism has appeared to cancel it. Counting the unknowns found that Maxwell’s rule is the difference between the number of states and the number of mechanisms, and says nothing of either alone.
So the equilibrium matrix of every one of the 256 patterns was built and its rank found. Every pattern has exactly as many states as shared joints, and none has a mechanism. Nine patterns have no shared joint: those whose K’s all point one way, or turn once away from the centre, LLLLRRRR, where two K’s open away from the same vertical and it receives none. Eighty-four have one, 126 have two, 36 have three. One pattern has four, the alternating one, and no girder of eight panels can have more, because a shared joint needs an R followed by an L and eight letters hold at most four such pairs.
The answer to the first question is therefore yes, without exception, for girders of this kind. It is the outcome that the forces that are there with nothing applied would lead one to expect, since each state is visibly a closed loop of forces around its own joint, and closed loops at different places are different loops. The count confirms that nothing else in the frame interferes.
States that touch through one member
Whether the states interact is a question about their members and their stiffness. If two states share no member, their amounts are fixed by two separate compatibility equations, each involving only its own members’ stretch, and each can be found as the earlier essay found its one. If they share members, the stretch of a shared member enters both equations, and the amounts must be found together.
In the turned-once and turned-three-times girders the states share nothing. In the alternating girder each neighbouring pair shares one full-height vertical, and the cross term in their compatibility equations — the sum, over shared members, of one state’s force times the other’s times the member’s flexibility — is 3 per cent of each state’s own term. The coupling exists and it is small. A designer can treat each shared joint as its own redundancy, with an error of a few per cent in its amount, even when the turns are as close as they can be.
That settles the second question too. The states are local, and so are their equations; a girder with four redundancies is four girders with one each, slightly overlapping.
Bending still leaves them alone, almost
The third question is whether a load can call on a state only through the state’s own members. The earlier essay found the reason it could not otherwise: each state is symmetric about mid-depth — its top and bottom chords compressed alike, its upper and lower diagonals pulled alike — while bending is antisymmetric about mid-depth, shortening the top chord and lengthening the bottom. The stretches bending gives the state’s members cancel term by term in the compatibility sum, and the state’s amount is zero.
In the turned-once girder, five of the seven load positions call on the state not at all, and the two that do — joints three and five, where the load comes down an upper half-vertical that belongs to the state — call on it with 30.1 kN of the diagonals’ sum for a 400 kN load. In the alternating girder the same rule holds for the state at the third vertical, with a different pair of joints: a load at joint two or joint four comes down a full-height vertical that belongs to this state and to its neighbour, compresses it, and calls on both states by about 28 kN. Loads at joints one, three, five and six, which enter no member of this state, call on it by less than 2 kN, the remainder being the 3 per cent coupling to neighbours that are themselves called on.
So the rule is the same for every pattern, and the alternating girder simply has more of its members inside some state. A load gets at a state through the members of that state, by compressing a vertical that belongs to it. A section calculation that ignores every state is exact for every load applied where no state’s member receives it, and within about a tenth where one does.
The tie that runs through the shared joint
Bending is antisymmetric about mid-depth, and that is why it leaves the states alone. An action symmetric about mid-depth has no such luck, and the earlier essay’s warm chords were one. A force along the girder is another, and it is not a temperature: it is a load.
Pull the girder from end to end and a section calculation puts the whole of the pull in the chords, 250 kN in each, and nothing in any web member, because a girder carrying no shear has no shear for its K’s to carry. That is right for every K with a joint of its own. At the shared joint it is wrong: at 500 kN of pull, both diagonals of each K there carry 50.2 kN of tension, a tenth of the pull, the same in the upper and lower diagonal.
The reason is visible in the state itself. The four diagonals meeting at one joint run from the chord joints at the left end of the two middle panels, through the shared joint, to the chord joints at the right end. They form a continuous inclined path from one end of the pair of panels to the other, in parallel with the chords over the same 6 m. A K with a joint of its own has no such path, because its two diagonals both start from the same side: its mid-depth joint is free to move along the girder until it has stretched neither. Four diagonals from both sides hold the joint between them. Whatever stretches the chords over those two panels stretches that second tie, and the tie takes its share by its stiffness. With the chords three times the diagonals’ area, its share is a tenth.
This is what the earlier essay’s warm chords were doing, seen as a load. It also means the state is not idle for loads in general. It is idle for loads that bend the girder, and fully active for loads that stretch it.
Heavier chords take more of it back
The share the diagonals take is set by the ratio of their stiffness to the chords’.
With chords only as heavy as the web members, each diagonal at a shared joint takes 22 per cent of the pull. At three times the web, the girder drawn throughout, 10 per cent. At twenty times, 2 per cent. The alternating girder’s numbers are a point or so lower, because its states’ outer members are full-height verticals rather than half-verticals and give a little more. A determinate girder, its K’s all turned one way, has no second tie and its diagonals take none of the pull at any ratio — the same absence of a second path that means a determinate truss has no robustness at all.
Girders whose chords are much heavier than their web are the common case, and there the effect is small. It is not small where the chords are light for their purpose. A roof’s horizontal bracing girder, whose chords are the edge members of the roof and whose web is chosen for wind shear, can have chords and web of similar size, and there the diagonals at a shared joint take a fifth of any axial force the girder carries.
The girder that is also a strut
A girder in a building often carries axial force as well as bending. A bracing girder in the plane of a roof delivers its wind to the braced bays through its chords, and those chords also act as the eaves strut for the bay’s column tops. A girder on a line of columns that is also a collector, carrying a floor’s horizontal force into a braced core, carries a push or a pull along its length as well as the floor’s weight. A section calculation designs each of these for its bending, from the shear in each K, and for its axial force, in the chords.
The section calculation gives the more compressed diagonal of the K beside the shared joint 55.9 kN, from the shear, whatever the push along the girder. The stiffness solution gives it 63.4 kN with no push — the earlier essay’s small difference, from the floor’s load on the half-verticals — and 163.8 kN under a push of 1,000 kN. The diagonal designed for 56 kN of compression carries nearly three times as much, and diagonals in a K-braced girder are the most slender members in it, chosen for modest forces in a girder whose shear is modest.
None of this applies to a K with a joint of its own. The section calculation is right there under any combination of bending and axial force. The error is confined to the K’s that share a joint, and it grows with the axial force rather than with the bending. A designer who solved such a girder by sections and checked the shared joint’s region for its bending, finding it nearly exact as the earlier essay said, would have checked the one action that cannot find it.
What the drawing of a state does not show
Every girder here is plane, pin-jointed and elastic, and its members are straight. Gusset plates make real joints partly rigid, and a rigid joint adds bending to every member and changes the shares; it does not remove the second path, which is made of axial forces and needs no rigidity. The diagonals are not allowed to buckle, so a compressed diagonal carries its force however large it grows; the point of the last figure is that its force is not the one it was designed for.
The axial force is applied at both ends, half to each chord, as a strut’s end connections would apply it. Applied to one chord only, it would bend the girder as well, which leaves the states alone, so it would call on them by the share of it that is axial. And the girders are eight panels long with K’s of one size. The question the earlier essay left about double K’s stacked in a panel, where each panel has two mid-depth joints and a turning pattern makes two shared joints on one vertical, is a different girder, and the counting here does not decide whether its two states on one vertical behave as two or as one.
Local redundancies, and the one action that finds them
The girder whose K’s turn back and forth has as many redundancies as it has turns, and each is a small loop of forces in two panels, touching its neighbours through a vertical when the turns are adjacent and otherwise not at all. For loads that bend the girder, those loops are nearly idle: a load reaches one only through its own members, and the method of sections, applied as if every K had a joint of its own, is exact for most loads and close for the rest. That is a strong result, and it is why girders like these can be designed by sections with so little error.
The loops are not idle for anything that stretches the girder along its length. Four diagonals meeting at one joint are a tie across two panels, in parallel with the chords, and they take a share of any axial force the girder carries — a tenth with ordinary chords, a fifth with light ones. Temperature and misfit found the same loops in the earlier essay; a push or a pull finds them as a load, and a girder used as a strut is a girder whose design load finds them.
Still open: two K’s stacked on one vertical
A double-K girder has two K’s in each panel, one above the other, their apexes at the third-points of the panel’s vertical. Turn the pattern and that vertical receives eight diagonals at two joints instead of four at one. The count gives two unknowns there, and there may be two states, one at each joint, or one state spread over both, with the short length of vertical between the joints as a member of each. Whether two states stacked so closely behave as a single tie of double strength, whether the third of the vertical between them carries the difference, and whether a load on the vertical between the joints — which is where a stacked K’s floor beam would be framed in — calls on them where a load at a chord joint does not, is the question the double K puts to the single.
Named alongside this one
Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.
- Any structure will carry the unit load compatibility · self-stress
- Bending that arrives as twist compatibility · self-stress
- Choose what to take away compatibility · indeterminacy
- One column is enough to find the sway compatibility · indeterminacy
- Six equations, and the drawing shows three indeterminacy · self-stress
- The analysis that assumes the answer compatibility · indeterminacy
The objects this essay names
Each one links to every other essay that touches it.
Axial forceCompatibilityEquilibrium matrixIndeterminacyK bracingMethod of sectionsSelf-stress