Series

Damping — the series

7 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. How much a harmonic force is magnified, at four damping ratios. Displacement amplitude divided by the deflection the same force would produce if it were applied slowly, against the ratio of the forcing frequency to the structure's own, at 1%, 2%, 5%, 10% of critical damping. At the natural frequency the magnification is 50, 25, 10, 5 respectively — one over twice the damping ratio, and nothing else in the problem enters it.

    The only thing that stops it

    Drive a structure at its own frequency and the amplitude grows without limit unless something takes energy out. What takes it out is damping, and damping is the one structural property that is never designed, never drawn, and never known until the thing is built.

    part 1 · dynamics
  2. A damper too large stops damping. The damping of a structure with 2.0% of its own, against the size of a viscous damper held by a brace — the damper's force over the brace's at the structure's own frequency, on a logarithmic scale — for braces a quarter as stiff as the structure, as stiff, and four times as stiff. With the brace at 0.25 the damping peaks at 7.9% for a damper of 0.86; with the brace at 1.00 the damping peaks at 22.7% for a damper of 0.58; with the brace at 4.00 the damping peaks at 63.9% for a damper of 0.29. Either side of the peak it falls: a small damper barely moves, and a large one barely strokes — it locks, and the brace carries the motion as a spring.

    The damper is only as good as its brace

    A viscous damper added to a frame is held by a brace, and the brace is a spring in series with it. That pair has a ceiling: the most damping it can add is (√(1+κ) − 1)/2, κ being the brace's stiffness over the frame's, reached at one damper size and lost on either side of it. A brace as stiff as the frame allows 20.7%; a quarter as stiff, 5.9%. A damper larger than the best one is not better — it strokes less, locks, and turns the brace into a strut that moves the resonance instead of flattening it.

    part 2 · dynamics
  3. Sized for one amplitude, a nonlinear damper damps only a band around it. The damping of a structure with 2.0% of its own and a brace as stiff as the structure, against the storey's amplitude over the amplitude the damper was sized for, on a logarithmic scale, for dampers whose force goes as the velocity to the power α, each sized to the brace's best at the design amplitude. All four give 22.7% there. The linear damper gives it at every amplitude. A tenth of the design amplitude, α = 0.5 gives 6.4%, α = 0.3 1.9% and α = 0.15 1.4%; a hundredth of it, 1.9%, 1.4% and 1.4% — below the structure's own, because the locked brace has stiffened it.

    The damper sized for the earthquake

    A fluid damper whose force goes as its velocity to the power 0.3 is chosen because it caps the force a large earthquake can push through its brace. The same exponent makes its effective size depend on how far it strokes. Sized to its brace's best at the earthquake's amplitude, it adds 20.7% of critical damping there, 5.4% at three-tenths of it, and nothing at all at a tenth — where the brace has locked, the building is stiffer, and the motion its occupants feel meets a resonance that is as sharp as an undamped frame's. Giving half the brace to a linear damper keeps 9.3% under the wind for 1.2 points at the earthquake.

    part 3 · dynamics
  4. The same damper behind a lever is best at a larger motion. The damping of one storey with 2% of its own damping and a brace as stiff as the storey, with an α = 0.3 damper sized to its brace's best at the design amplitude with no amplifier, against the storey's amplitude, with the same damper behind stroke amplifiers of ratio 1, 2 and 3. A ratio f makes the damper act on the storey as one f to the power 1 + α larger — 2.46 and 4.17 times — so it locks more, and its band moves up by about f to the power (1 + α)/(1 − α): its best is near 3.8 and 7.5 times the design amplitude. At a hundredth of the design amplitude all three give 1.4%; at the design amplitude 22.7%, 6.4% and 2.3%.

    The lever that moves the damper and not the band

    A damper whose force goes as a low power of its speed is sized for the earthquake and locks in the wind. A toggle or scissor linkage multiplies its stroke, and it seemed it might move the band of amplitudes the damper serves down towards the wind. It cannot. Behind a lever of ratio f the same damper acts on the storey as one f to the power 1 + α larger, so its band moves up, not down; re-sized to the design amplitude, it gives the storey exactly the curve it had without the lever, and what has changed is the damper — a quarter of the size, a third of the force, three times the stroke. What would widen the band is a ratio that grows with the motion, and a toggle has one — until its links lie straight and it locks.

    part 4 · dynamics
  5. One record, with no mass, with a mass free to travel and with its stops. The first-mode displacement of a 4 s building with 1.5% damping through one record at a peak ground acceleration of 3.0 m/s²: bare, peaking at 0.92 m; with a 2% tuned mass free to travel, 0.91 m, the mass moving 3.2 m; with the mass stopped at ±0.50 m, 0.92 m, after seventeen impacts. The free mass's effect is in the tail of the record, where it takes 35% off the root mean square; the stopped mass takes 3%.

    The tuned mass that sits out the earthquake

    A tuned mass sized for a tall building's wind sway has a stroke of half a metre and bumpers at each end. In an earthquake it would need three. The fear is that the stopped mass becomes a hammer inside the building. It does not: the building's peak never rises by more than a per cent. What the stops take away is a benefit the mass gives the tail of the shaking and never gave its peak, and what they add is a force on the mass's own supports, set by how soft the bumpers are.

    part 5 · dynamics
  6. The mass in the wind, and then the earthquake. The tuned mass's stroke relative to the building over the last twenty seconds of a steady wind and the first twenty of an earthquake at 1.0 m/s², the wind still blowing. The wind swings the mass to ±0.40 m of its ±0.50 m; the record drives it into its stops 16 times, at up to 0.89 times its weight.

    The stroke the wind has already spent

    A tuned mass built for a tower's comfort in wind is given a stroke and a pair of stops, and an earthquake that drives it into them costs the building almost nothing. That was found for a mass at rest when the ground began to move. A mass in a breeze is not at rest. Swinging through 0.4 m of its 0.5, it meets its stops sixteen times in an earthquake that would barely have touched them, and what pays is not the building but the stops: a small earthquake on a windy day loads them as a large one on a calm day would.

    part 6 · dynamics
  7. The mass's path in plan, the wind's swing and then the earthquake across it. The tuned mass's stroke in plan over the last twenty seconds of a wind that swings it ±0.40 m along its line and the first twenty seconds of an earthquake of 1.0 m/s² arriving 90° from that line, inside a ring of stops 0.50 m in radius. In the earthquake the mass strikes the ring 25 times, at up to 0.72 times its weight; its largest stroke across the wind is 0.51 m.

    The ring the mass swings inside

    A tall building's tuned mass is usually swung by the wind across one line, and an earthquake can arrive from any direction. If the mass runs on two tracks with stops on each, an earthquake at right angles to the wind's swing finds its whole stroke free: the wind costs nothing. If it hangs inside a ring of stops, the two strokes add as a vector and the ring is nearer than it looks. In a moderate earthquake across a wind that already swings the mass ±0.40 m of its ±0.50, the ring is struck 2.6 times a record against 0.5 between pairs and 8.0 along the wind's line. In a strong one the ring is struck more often across the wind than along it.

    part 7 · dynamics

All series