Dynamics

The tuned mass that sits out the earthquake

A tuned mass sized for a tall building's wind sway has a stroke of half a metre and bumpers at each end. In an earthquake it would need three. The fear is that the stopped mass becomes a hammer inside the building. It does not: the building's peak never rises by more than a per cent. What the stops take away is a benefit the mass gives the tail of the shaking and never gave its peak, and what they add is a force on the mass's own supports, set by how soft the bumpers are.

Assumes The mass that helps by being late and The only thing that stops it.

The lever that moves the damper and not the band found that a viscous damper of low exponent locks up in the wind, and that no lever between it and the storey undoes that without a ratio that grows many times over the motion. The device that damps the wind without competing for a brace is a tuned mass: a heavy block on springs and dampers near the top of the building, tuned to the building’s first mode, which moves out of step with the building and drains its energy. A building that needs comfort in the wind and safety in an earthquake might carry both — the mass for the first, the dampers for the second.

The difficulty is the mass’s stroke. A mass sized for wind is given a stroke to match the wind: half a metre each way, perhaps a metre in a very tall tower, with bumpers at each end because the room it sits in is finite. An earthquake drives the building harder than the design wind, and the mass, tuned to move further than the building, would move further still. So it hits its bumpers. The question the earlier essay left is whether the bumpers then turn the mass into one more impact the frame must carry — whether a building would be better off in an earthquake with no mass at all.

A wind mass on a four-second building

The building is its first mode: a period of 4 s, a modal mass of one, 1.5 per cent of critical damping, which is what a steel or composite tower of forty storeys is usually credited with. The mass is 2 per cent of the modal mass, tuned and damped by Den Hartog’s rule for a harmonic force — 0.98 of the building’s frequency and 8.6 per cent of its own critical damping. That rule is what a mass for wind comfort is sized by, and on this building it brings the resonant amplification from 33 to 8, a factor of four.

The mass has ±0.5 m of stroke. At each end is a bumper, a spring and a dashpot that act only in contact, stiff enough that the mass pressed onto it alone would rebound in 0.2 s, with a coefficient of restitution of a half.

The ground moves by a filtered noise: white noise through a soil filter of 1 s period and 60 per cent damping, under an envelope that rises for 2 s, holds to 10 s and then decays, for 40 s. Each seed is a different record of the same kind of earthquake, and the numbers below are means over ten seeds, scaled to a peak ground acceleration that is varied from a quarter of a metre per second squared — a tremor — to six, a very strong earthquake.

One record, with no mass, with a mass free to travel and with its stops. The first-mode displacement of a 4 s building with 1.5% damping through one record at a peak ground acceleration of 3.0 m/s²: bare, peaking at 0.92 m; with a 2% tuned mass free to travel, 0.91 m, the mass moving 3.2 m; with the mass stopped at ±0.50 m, 0.92 m, after seventeen impacts. The free mass's effect is in the tail of the record, where it takes 35% off the root mean square; the stopped mass takes 3%.
Fig. 1 The building’s first-mode displacement through one record at a peak ground acceleration of 3 m/s². Bare, it peaks at 0.92 m; with the mass free to travel, at 0.91, the mass moving 3.2 m; with the mass stopped at ±0.5 m, at 0.92 after seventeen impacts. The free mass takes 35% off the mean square of the shaking, all of it after the peak; the stopped mass takes 3%.

The figure shows one record at 3 m/s², about a third of the acceleration due to gravity. For the first ten seconds the three curves are one curve. The building’s largest swing, 0.92 m, comes at eleven seconds, in the first strong cycle after the ground motion has built up, and all three buildings make it. After that the free mass takes hold: each cycle is smaller than the bare building’s, and by thirty seconds the building with the free mass is barely moving while the bare building is still swinging at half its peak. The free mass moves 3.2 m to do it.

The stopped mass cannot. Held to half a metre, it hits its bumpers seventeen times, and its building’s curve is the bare building’s, shifted a little later in each cycle by the extra mass that rides along with it while it is pressed against a bumper. Its effect on the tail is 3 per cent.

The peak is over before the mass has moved

That figure already contains the answer to the question, and it is not the answer the question expected. The stopped mass does not make the building worse, because there was very little for the stops to take away from the peak in the first place.

The building's peak, with the mass free and stopped, over the bare building's. The mean over ten records of the building's peak displacement, as a share of the bare building's, against the peak ground acceleration. A 2% mass free to travel takes 5% off it at every level, because the peak comes before the mass has built up. Stopped at ±0.50 m it stands at 95% of the bare building's peak at 0.5 m/s², 98% at 2 and 100% at 6, and never above it by more than a per cent.
Fig. 2 The mean over ten records of the building’s peak displacement, as a share of the bare building’s, against the peak ground acceleration. A free mass takes 5% off it at every level. Stopped at ±0.5 m it stands at 95% of the bare peak at 0.5 m/s², 98% at 2 and 100% at 6, and never above it by more than a per cent.

The free mass takes 5 per cent off the peak at every level of shaking, which is all a 2 per cent mass on a lightly damped building can do in an earthquake. The same mass took three quarters off the resonant response to a steady force, so the difference is not in the mass but in the excitation. A harmonic force at resonance builds the building’s motion over dozens of cycles, and the mass, moving out of step, drains each one; the steady state is a balance between the two. An earthquake’s strong motion delivers most of its energy in two or three cycles. The building’s peak is its response to those, and a tuned mass needs several cycles of the building’s motion to build its own. By the time it is moving enough to matter, the peak has been made.

The time it takes can be put as a number. A tuned mass is coupled to its building through its own spring and dashpot, and its motion builds up, or dies away, with a time constant of one over its damping ratio times its frequency: on this building 7.6 s, nearly two of the building’s periods. The record’s strong motion lasts eight seconds, from the end of its two-second rise to the start of its decay. So the mass reaches most of its working amplitude about when the strong motion ends, and the building’s largest swing, in the second or third strong cycle, meets a mass that is still getting going. A mass with more damping would build up faster and be less well matched to the building; a heavier one does more, but at 5 per cent of the modal mass it still takes only 9 per cent off the mean peak at 3 m/s². Neither has the peak within reach. A device that acts on the first cycle has to be one whose force depends on the building’s motion now, not on a motion of its own built over many cycles, which is what a viscous damper in a brace is.

With the stops, the 5 per cent shrinks as the shaking grows, and by 6 m/s² it has gone: the stopped mass leaves the bare building’s peak where it was. It never adds to it by more than a per cent, at any level of shaking or on any record. The mass pressed against its bumper is a 2 per cent mass riding with the building, which lengthens its period by a per cent and changes nothing else. The bumper force between them is internal to the building, and the building’s sway, which is what the peak measures, is set by the ground and not by what its parts do to each other.

Where the mass did its work

The mean square of the shaking, with the mass free and stopped. The mean over ten records of the root mean square of the building's displacement through the record, as a share of the bare building's, against the peak ground acceleration. Free to travel, the mass takes 30% off it at every level. Stopped at ±0.50 m: 29% at 0.5 m/s², 18% at 1, 6% at 2 and 0% at 6.
Fig. 3 The mean over ten records of the root mean square of the building’s displacement through the record, as a share of the bare building’s, against the peak ground acceleration. Free to travel, the mass takes 30% off it at every level. Stopped at ±0.5 m: 29% at 0.5 m/s², 18% at 1, 6% at 2 and nothing at 6.

The mean square of the displacement over the whole record is where the free mass earns its place. It takes 30 per cent off, on every record and at every level, because a linear system scales: double the shaking and every motion doubles, so every ratio stays where it was. That 30 per cent is the shaking after the peak, the long ringing tail that a lightly damped tall building carries on with for a minute after the ground has stopped. It is what the occupants feel, what the cladding’s joints work through, and what decides how many large cycles a damaged connection must survive. The only thing that stops it called damping the one property that is never designed; a tuned mass is the case where it is, and its effect is on duration rather than on peak.

The stops take that back. At half a metre per second squared the mass hardly reaches its bumpers and keeps 29 of its 30 per cent. At one it keeps 18; at two, 6; at six, nothing. The stopped system is no longer linear, so the ratio depends on how strongly the ground shakes against how much stroke the stops allow, and the mass’s benefit falls away as the shaking outgrows the stroke. What it falls to is the bare building, not something worse.

The stops therefore cost exactly what the mass would have done for the tail of a strong earthquake, and nothing more. For a building whose mass was bought for the wind, that was never part of the design. The free mass’s 30 per cent in an earthquake was a bonus the stroke budget does not pay for.

Three metres of travel

How far the mass wants to travel, and how far it is let. The mean over ten records of the mass's peak stroke relative to the building, against the peak ground acceleration: free, 0.76 m at 1 m/s² and 4.6 m at 6; stopped at ±0.50 m, 0.59 m at 6, pressed 19% into its bumpers, 21 impacts a record.
Fig. 4 The mean over ten records of the mass’s peak stroke relative to the building, against the peak ground acceleration: free, 0.76 m at 1 m/s² and 4.6 m at 6. Stopped at ±0.5 m, it reaches 0.59 m at 6, pressed 19% into its bumpers, with twenty-one impacts a record.

The free mass’s stroke scales with the shaking: 0.76 m at 1 m/s², 4.6 m at 6. On a building whose modal displacement peaks at 1.5 m at that level, the mass is moving three times as far as the building. The mass that helps by being late found the same under a steady force, where a 3 per cent mass’s stroke was thirty times the structure’s static deflection and a 1 per cent mass’s nearly eighty: a light absorber does its work by moving a long way.

No building can give a mass four and a half metres. Stopped at half a metre, the mass presses 9 cm into its bumpers at 6 m/s², a fifth of its stroke again, and strikes them twenty-one times in a record. Every one of those is a collision between a mass of two per cent of the building’s modal mass and the structure that holds it.

The force on the room the mass sits in

The building’s sway does not see those collisions, but the structure under the bumpers does. The bumper force is set by how stiff the bumper is, as twice the deflection for the same load found for any load that arrives suddenly: a stiffer stop decelerates the mass in a shorter time, with a larger force.

The force the stops must take, against how soft they are. The mean over ten records of the peak bumper force, over the mass's weight, at a peak ground acceleration of 3.0 m/s², against how long half a cycle of the mass on the bumper would last. 6.1 times the weight for a 0.05 s contact, 1.6 at 0.2 s and 0.4 at 0.8 s; the building's peak barely moves, 100% of the bare building's against 98%.
Fig. 5 The mean over ten records of the peak bumper force, over the mass’s weight, at 3 m/s², against how long half a cycle of the mass on the bumper would last. 6.1 times the weight for a 0.05 s contact, 1.6 for 0.2 s and 0.4 for 0.8 s. The building’s peak is 100% of the bare building’s with the hardest bumper and 98% with the softest.

The force falls almost exactly in proportion to the contact time: 6.1 times the mass’s weight for a stop that holds the mass for 0.05 s, 1.6 for 0.2 s, 0.4 for 0.8 s. A hard steel stop is nearer the first; a rubber or hydraulic buffer the last. The building’s peak hardly moves across that range, from 100 per cent of the bare peak with the hardest stop to 98 with the softest, which lets the mass keep a little more of its motion.

It is the same collision that the gap between two buildings dealt with between neighbouring towers, at a smaller scale and with one difference that helps: the two parties to this one are designed by the same engineer, who can choose the buffer. For a mass of several hundred tonnes, six times its weight is a horizontal force of thousands of tonnes applied at the bumpers, at the top of the building, in a floor that was designed to hold a mass and its springs. That is the impact the frame must carry, and it is a local one: the bumpers’ frame, the floor diaphragm round them, the connections that carry the force into the core. A first-mode model of the building cannot say what that force does to the building’s higher modes, and a sharp blow at the top of a tall building excites them. The design consequence is plain and inexpensive: the stops should be soft. A buffer that lengthens the contact to most of a second cuts the force by a factor of fifteen and costs the building nothing.

How much stroke would keep the mass working

What the stops leave of the mass's effect, against the stroke allowed. At a peak ground acceleration of 3.0 m/s², the mean root mean square of the building's displacement and its mean peak, as shares of the bare building's, against the stroke the stops allow. At ±0.25 m the mass does nothing; at ±1.00 m it takes 10% off the mean square; at ±3 m, 29%, which is the free mass's 30%.
Fig. 6 At 3 m/s², the mean root mean square of the building’s displacement and its mean peak, as shares of the bare building’s, against the stroke the stops allow. At ±0.25 m the mass does nothing. At ±1 m it takes 10% off the mean square; at ±3 m, 29%, the free mass’s 30%. The peak gains at most its 5%.

At 3 m/s² the mass needs about three metres each way to keep its effect, and a metre buys a third of it. Because the bumpers are linear springs beyond a gap, the stopped system has one length scale, and doubling the stroke does the same as halving the shaking: the stroke that keeps the mass working in a given earthquake is that earthquake’s free stroke, whatever the earthquake is.

The peak is not on offer at any stroke. Even a free mass takes only 5 per cent from it, so the stroke a designer might add for the earthquake buys the tail and not the peak. Whether a building’s earthquake design wants its tail shortened depends on what is being designed for. For a structure designed to stay elastic, the peak is what decides the members, and the mass does not help with it. For one whose connections are designed to yield in a controlled way, the number of large cycles they must survive is what decides their detailing, and that is where a long stroke would earn something.

The dampers that make the mass unnecessary

The building that needs both kinds of damping has one more interaction to consider. The dampers for the earthquake raise the building’s own damping, and a tuned mass’s effect depends on how lightly damped the thing it is draining is.

What the mass is worth, against the building's own damping. The mean root mean square and peak of the building's displacement with a free 2% mass, as shares of the same building without it, against the building's own damping ratio, at a peak ground acceleration of 1 m/s². At 1.5% the mass takes 30% off the mean square; with dampers bringing it to 5%, 12%, and to 8%, 6%.
Fig. 7 The mean root mean square and peak of the building’s displacement with a free 2% mass, as shares of the same building without it, against the building’s own damping, at 1 m/s². At 1.5% the mass takes 30% off the mean square; with dampers bringing the building to 5%, 12%; to 8%, 6%. The peak gains under 5% throughout.

With dampers bringing the building to 5 per cent of critical — the damper sized for the earthquake reached more than 20 per cent at its own design amplitude — the free mass takes 12 per cent off the mean square instead of 30; at 8 per cent, 6. The dampers shorten the tail themselves, and a tuned mass has nothing left to drain. In the earthquake the two devices do not add; the dampers make the mass’s earthquake effect small, and the stops make it nothing.

That is a reassuring answer to the question the earlier essay posed. A building can carry a tuned mass for its comfort and dampers for its safety, and the mass’s stops need not be sized to keep it working in the earthquake. They need to be sized to stop it gently: the mass is a passenger in the earthquake, and the only design question it raises is the force with which it is caught.

What a first-mode model cannot say

The building here is its first mode, an oscillator of one degree of freedom. That is the right model for the sway that the mass is tuned to, and it is why the bumper impacts are invisible in the building’s peak: an impulse at the top of a real tower would also ring its second and third modes, at a third and a fifth of its period, and the floor accelerations near the mass would carry spikes that this model cannot produce. The bumper force is the input to that calculation, and it is the number this model can give.

The building stays elastic. At 6 m/s² a real building of this period would be yielding in its designed fuses, its period lengthening and its damping rising, and both would move it away from the mass’s tuning. A detuned mass does less, so the mass’s effect in a damaging earthquake is smaller than the numbers here, not larger, and the conclusion that it cannot make the building worse is safe.

The records are filtered noise, stationary inside their envelope, with no long-period pulse. A record from near a fault, with one large pulse of velocity, would deliver its energy in one cycle and leave the mass even less time. And the mass is tuned for a harmonic force; the wind is a spectrum, and a mass tuned for a spectrum is tuned and damped a little differently, which moves every ratio here by a little and none of the conclusions.

A passenger to be caught gently

The fear about a tuned mass in an earthquake is that its stops turn it into a hammer. The computation says the hammer strikes the bumpers, and only the bumpers. The building’s peak is decided in the earthquake’s first strong cycles, before the mass can move enough to matter, and so neither the free mass nor the stopped one changes it by much; the free mass would have shortened the shaking’s tail, and the stops take that away as the shaking outgrows the stroke. The cost of the stops is a benefit nobody paid for, and the cost of the collisions is a force on the mass’s own supports, which a soft buffer reduces at no cost to anything else.

Still open: the mass whose stroke is used up by the wind

Every record here starts with the mass at rest. A tall building’s earthquake does not arrive on a calm day by appointment, and a mass that is already swinging through half its stroke in a strong wind meets the earthquake’s first strong cycle with a fraction of its stroke left in one direction and its whole stroke in the other. Whether a mass caught mid-swing strikes its bumpers in the first strong cycle — at the building’s peak, where it would add to the sway instead of riding with it — or whether the wind’s motion and the earthquake’s are so different in frequency content that the starting state is forgotten in a cycle or two, is the question that the wind and the earthquake, designed for separately, put to the device that sits between them.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

What links here

Every essay whose body links to this one.

The objects this essay names

Each one links to every other essay that touches it.

DampingImpactNon-linear responseResonanceResponse spectrumStrokeTuned mass damper