The stroke the wind has already spent
Assumes The only thing that stops it and The mass that helps by being late.
The tuned mass that sits out the earthquake took a 40-storey tower with a 4 s first period and 1.5 per cent damping and gave it a tuned mass of 2 per cent of its modal mass, tuned and damped by Den Hartog’s rule, the rule a mass for comfort in wind is sized by. Free to travel, that mass brings the tower’s resonant amplification from 33 to 8. In an earthquake it does much less, 5 per cent off the peak, because the peak arrives in the first strong cycles before the mass has built up its motion. Given a stroke of ±0.5 m and a pair of bumpers at each end, as real masses are, it lost only its effect on the tail of the record and never added more than a per cent to the building’s peak. The cost of the stops was elsewhere: in the force on the bumpers and the structure that holds them.
Every record in that essay started from rest. The building was still, the mass was centred, and the ground began to move. A tower that has a tuned mass for wind has it because the wind moves the tower, and a tuned mass that is doing its job is moving as well, further than the tower, every day the wind blows. The earthquake does not wait for a calm. That essay ended by asking what happens to a mass whose stroke the wind has already used when the ground starts to move — whether the stops, which were barely touched by a small earthquake from rest, are reached by the same earthquake on a windy day, and whether the building then pays for them.
A wind that has found its frequency
The wind here is a steady harmonic force on the tower’s first mode, at the tower’s own frequency, 0.25 Hz. That is the simplest stand-in for what the wind that brings its own frequency described: a tall building’s wind response is dominated by the narrow band of gust energy at its own frequency, and its motion in that band is nearly a sine. The force is scaled so that the free mass’s steady swing is a chosen stroke — 0.2 m, 0.4 m — and it runs for two minutes before the earthquake starts, long enough for the tower and the mass to settle into their steady motion, and on through the record.
At 0.4 m of stroke the tower itself moves 0.07 m; the same wind on the bare tower would move it 0.33 m, nearly five times as far, which is the mass doing what it was installed for. The earthquakes are the same ten filtered-noise records as before, on a soil of 1 s period, at peak ground accelerations from 0.25 to 3 m/s². The wind’s phase at the moment each record begins is different for each record, so that the ten records also sample ten points in the wind’s swing at which the ground begins to move.
Two motions, and the stops in between
The trace shows one record. Before the earthquake the mass swings steadily through ±0.40 m, a sine with a 4 s period and a margin of 0.1 m to the stops at each end. The ground then begins to move, and the earthquake’s motion of the tower adds to the mass’s swing on some cycles and subtracts on others. On the first cycles where it adds, the margin is gone, and the mass strikes. In this record it strikes sixteen times in forty seconds, at up to 0.89 times its own weight.
From rest the same record at the same intensity drove the mass into its stops a handful of times. The difference is not that the earthquake is stronger, but that the earthquake had 0.5 m of travel to cross before the stops and now has 0.1, on the cycles where the two motions are in phase. A margin is a distance, and the wind has used four fifths of it.
The stops reached by a small earthquake
The count of impacts makes the point at its plainest. At a peak ground acceleration of 0.5 m/s² — a small earthquake, of the kind a site in a moderate seismic zone sees several times in a building’s life — the mass from rest strikes its stops half a time a record: in most records not at all. With 0.2 m of wind stroke it strikes 2.3 times, and with 0.4 m, 8.0 times. A mass whose stops were never meant to see a small earthquake meets them every few seconds of one.
At larger intensities the wind matters less. By 2 m/s² the mass from rest strikes fourteen times a record and with 0.4 m of wind stroke, seventeen. The earthquake alone already drives the mass through its stroke on most cycles, and the wind’s contribution is lost in it. So the wind changes the frequency of impact most for the small earthquakes, the ones a stop is least likely to have been checked against.
What the stops are asked to take
The force on the bumpers follows the same pattern. Each bumper is a spring and a dashpot that acts only in contact, set so that half a cycle of contact would last 0.2 s and the mass would rebound at half its approach speed; its force rises with the speed at which the mass arrives and the distance it presses in. From rest, a 0.5 m/s² earthquake gives a peak bumper force of 0.10 times the mass’s weight. With 0.4 m of wind stroke the same earthquake gives 0.42. A force of 0.42 times the weight is what the earthquake from rest reaches at about 0.8 m/s², so on a windy day the bumpers see the earthquake as if it were half as large again.
For a 2 per cent mass on a 40-storey tower the mass is several hundred tonnes, and its weight times 0.42 is a horizontal force of a meganewton or more on the bumper, the bumper’s frame and the floor that carries it. The earlier essay found the bumper forces were the real cost of the stops; here the wind moves that cost down the scale of earthquakes, to intensities at which a design would not have expected the stops to be touched. At 3 m/s² the wind adds 11 per cent to a force that is already 1.56 times the weight.
The building hardly notices
The tower itself is less affected than its stops. With no wind the stopped mass leaves the tower’s peak within 4 per cent of a free mass’s at every intensity. With 0.4 m of wind stroke the stopped mass costs 5 per cent at 1 m/s² and 6 at 3. The tower’s peak in an earthquake comes from the first strong cycles, as before, and a mass that strikes its stops in those cycles cannot do much worse than a mass that is not yet effective, which is what a free mass is in those cycles.
What the building gains from the mass in the wind is much larger than anything the stops cost it in the earthquake. With the wind still blowing through the record, the bare tower at 1 m/s² peaks at 1.71 times what the tower with its stopped mass reaches, because the bare tower carries the wind’s resonant motion, five times larger without the mass, into the earthquake with it. That is a different statement from the one about the earthquake alone, and it is the right comparison for a tower in a wind: the mass has already earned its place before the ground moves, and the stops take back a few per cent of what it earned.
The stroke that would avoid them
A designer who wanted the mass never to strike would size its stroke for the earthquake and the wind together. The obvious sum is the wind’s stroke plus the earthquake’s.
The sum overestimates it. At 1 m/s² a free mass from rest reaches a peak stroke of 0.76 m in the mean record; with 0.4 m of wind stroke, 0.97 m — 0.21 m more, about half the wind’s stroke. The two motions are at nearly the same frequency, since the mass is tuned to the tower and the earthquake drives the tower at its own period, but not at the same phase: the earthquake’s largest cycle meets the wind’s swing at a random point in it, and only rarely at its crest. The stronger the earthquake, the less the wind adds, 0.27 m at 0.5 m/s² and 0.17 at 2, because the earthquake’s motion is then the whole of the peak and the wind’s is a small part of one cycle.
So the stroke an earthquake needs on a windy day lies between two simple rules. Adding the two strokes, 1.16 m at 1 m/s², overstates it, because the two oscillations are not in step. The root of the sum of their squares, 0.86 m, understates it, because they are at nearly the same frequency and so drift in and out of step slowly, and over a forty-second record the earthquake’s strongest cycles are likely to meet the wind’s swing somewhere near its crest. The computed 0.97 m is two thirds of the way from the second rule to the first. It does not make the stroke small. A mass that needs 0.76 m for an earthquake from rest needs nearly a metre on a windy day, and twice the stroke a comfort design provides.
Where in the swing the ground begins
The means hide how much one record depends on when it starts. Moving the wind’s phase at the record’s start through one 4 s cycle, with everything else held, moves the peak bumper force in the same record from 0.56 to 1.24 times the mass’s weight and the tower’s peak from 0.23 to 0.39 m. When the earthquake’s first strong pulse catches the mass near the end of its swing and moving outward, the two motions add and the mass arrives at its stop fast; when it catches the mass moving inward, the pulse partly cancels the swing, and the tower and the mass both stay smaller.
A designer cannot choose where in the swing the ground begins. The ten records average over it, and the averages are what a design would use, but a single earthquake arrives at one point in the wind’s swing, and the scatter about the average is wide. The bumper force a design has to cover is the high end of that scatter rather than its mean. Read that way, the factor of four the wind adds at 0.5 m/s² is an underestimate of what a particular small earthquake can do on a particular windy day.
Forty storeys, and what a bumper is asked for
The ratios become forces once the tower has a size. A 40-storey tower of about 60,000 tonnes has a first-mode modal mass of perhaps two thirds of that, and a 2 per cent mass is then some 800 tonnes: a block of steel or concrete, or a tank of water, hung or sliding at the top of the building, weighing 8 MN. A peak bumper force of 0.42 times its weight is 3.3 MN; of 1.24 times, the worst phase in one record at 1 m/s², about 10 MN, delivered in a contact lasting a fifth of a second to a frame bolted to the roof structure.
That load is applied locally, to one frame on one floor, and it is applied repeatedly: eight times in a record at 0.5 m/s², seventeen at 2. A bumper of rubber or a hydraulic buffer is rated for a number of strikes at a stated energy, and a frame designed for one strike from an earthquake that reaches it rarely is asked here for many strikes from an earthquake that reaches it often. Twice the deflection for the same load is the reminder that a load arriving suddenly does twice what the same load does slowly, and a bumper strike is a load that arrives in a fraction of the bumper frame’s own period.
None of this changes what the mass does for the tower. The mass that helps by being late explained that a tuned mass works by moving out of phase with its building and so needs time and travel to work at all; half a spring is neither tuning nor freedom and taking hold is harder than letting go found what is lost when that travel is limited by other means. The stops here limit it in the most abrupt way, and the wind makes them do so in earthquakes that would otherwise have left the mass free. What an earthquake asks of a tall building is, as the earthquake asks for a displacement put it, a displacement; what it asks of the mass’s stops, on a windy day, is a series of blows.
The model’s two simplifications
The wind is a pure sine at the tower’s frequency, so the mass’s swing before the earthquake is perfectly regular. A real wind’s response is a narrow-band random process whose amplitude wanders over minutes, and the stroke the wind has used at the moment the earthquake arrives is itself a random variable. A sine of the right amplitude is the case of a wind that is steady at its design intensity; a real wind at the same mean would sometimes have used more stroke and sometimes less.
The tower is one mode, linear and lightly damped, and the earthquake is a filtered noise. A real tower’s higher modes are excited more by the earthquake than by the wind, and a mass tuned to the first mode does nothing for them; the peak displacement of the first mode is the only response measured here. The bumpers are linear springs with a dashpot that acts only in contact, of fixed stiffness, and the mass moves in one direction. A mass on a pendulum or on bearings moves in two directions, and a wind from one side with an earthquake from another drives it diagonally into a ring of stops. The damper sized for the earthquake is the other way of meeting an earthquake with damping, by sizing the device for the earthquake from the start, and nothing here applies to it.
A margin is a distance
The general point is about margins in dynamic systems. A stop is a margin measured as a distance from a resting position, and a system that is moving is not at its resting position. Any steady motion uses part of the margin, and a transient that arrives during it has only what is left. For a tuned mass the steady motion is the one it was installed to have, so the margin it leaves is always smaller than its nominal stroke in exactly the conditions — a strong wind — in which it is doing most of its work. The building barely pays for that, because the earthquake’s peak is reached before any mass matters. The stops pay, and they pay most against the small earthquakes that a design would have assumed never reached them.
The lesson for a designer is to check the stops against an earthquake during a frequent wind as well as against one in calm, and to size the stroke between the root of the sum of the squares of the two and their sum: nearly a metre for this mass at 1 m/s², and an impact count that tells the bumpers what to expect.
Still open: the mass in a wind from another direction
The wind here swings the mass along the same line the earthquake moves the tower. A tower’s tuned mass usually moves in two directions, on a pendulum or on a pair of tracks, and the wind most often swings it across the wind, where vortex shedding drives the tower, while an earthquake can arrive from any direction. If the earthquake’s motion is at right angles to the wind’s swing, the two strokes combine as a vector, and the mass meets a ring of stops rather than a pair. Whether the margin left at right angles to the swing is nearly the whole stroke, so that an earthquake across the wind costs the stops little, or whether a mass swinging on a pendulum loses its tuning in the direction it is not swinging, needs the mass and the tower in two directions with a stop that is a circle.
Named alongside this one
Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.
- The actuator that arrives late damping · resonance · tuned mass damper
- The actuator that pushes against the mass damping · resonance · tuned mass damper
- The law that throws the tuning away damping · resonance · tuned mass damper
- The lever that moves the damper and not the band damping · non-linear response · wind load
- The switch that hands the mass back resonance · stroke · tuned mass damper
- The tank that follows the building damping · resonance · tuned mass damper
What links here
Every essay whose body links to this one.
The objects this essay names
Each one links to every other essay that touches it.
DampingImpactNon-linear responseResonanceStrokeTuned mass damperWind load