Crack spacing — where it appears
Named by 3 essays across 2 fields — each of them below, with the objects they name alongside it.
The same steel, and a wider crack
A crack's width is the distance between cracks times the strain the steel carries over that distance. Neither of those is decided by how much reinforcement there is. The spacing is a bond length, so it goes as the bar diameter; the strain is set by the stress in the steel. Two arrangements of identical steel can differ by a factor of two in crack width, and the one that wins is the one with more, smaller bars.
The steel decides how many, not how much
A wall cast on a base that has already set cools, tries to contract, and is not allowed to. What follows is not a stress problem with a strength on the other side of it. The movement is going to happen; the only question the reinforcement gets to answer is how many pieces it is divided into.
The bay that is cast last
A wall cast on a base cracks in a way the steel controls: more movement gives wider cracks, and reinforcement decides how many. A bay cast between two walls that have already hardened cracks in a way that has nothing to do with how much movement there was — and the threshold that separates a controlled crack from a single wide one is a quantity of steel rather than a limit on anything.
Named alongside it
The objects these essays reach for when they reach for this one.
BondCrack widthMinimum reinforcementServiceabilityShrinkageTensile strengthBar diameterCharacteristic strengthConstruction sequenceCorrosionCoverDurability