One support too many — page 9
The joint chosen for one wind
A frame's beam carries more moment at one end than the other when the wind pushes, so it seems that each end's joint could be chosen for its own end, softer where the moment is larger, and the beam brought to its plastic moment everywhere at once. Chosen that way the first hinge rises to 94 per cent of the collapse load and no further, because the wind takes off one end what it adds to the other. And the wind turns round.
The bars in the first metre from the web
A cracked concrete deck over a pier spreads a girder's tension into its width only as far as its bars let it, and the earlier calculation smeared those bars evenly across the deck. A drawing never does. With the bars where a drawing puts them, the width over the pier turns out to be decided almost entirely by the steel within a metre of the web — the transverse bars there set how far the tension reaches, and longitudinal bars moved there do more than the same bars spread out.
The weaker half sets the beam
A girder with a wide top flange and a narrow bottom one is nearly twice as hard to buckle sideways as the equal-flanged girder made from the same steel, provided the moment keeps its wide flange in compression. Put the beam in double curvature and the half whose narrow flange is compressed takes over: the critical moment falls from 2,151 kN·m to 863, below the 1,455 of equal flanges, and the strong half lends the weak one only twelve per cent.
What the joints in a viaduct are for
A long viaduct is usually built as continuous groups of three or four spans with a movement joint between them, and the grouping is often explained as a compromise between continuity's economy and a chain of simple spans' indifference to settlement. Computed, settlement does not take part in the compromise: two spans continuous already feel a sinking pier as the whole viaduct would. Nor does robustness, much. What the joints are for is the movement of the deck, and what the group's size buys is the moment of the traffic.
The lip that holds the wrong thing
A thin strip bent along its length curls sideways into a saddle and stays a beam; held at its edges, it becomes a plate and is a tenth stiffer. A lip rolled along each edge looks like the way to hold them. It is not. A lip pushes back on an edge that moves out of line, with a stiffness made of the very curvature it resists, and it holds the edge's position but not its slope — so at the small curvatures of service even a lip of unbounded size leaves the strip within 1.5 per cent of a beam. What makes a plate of a gently bent strip is a neighbour that stops its edges turning.
The arch that pushes harder as it spreads
A masonry arch whose abutments move apart does not fall when they first move. It cracks at its crown and its haunches, turns into a mechanism of three hinges, and keeps standing while its crown drops — and the thrust it puts on the abutments that are already giving way rises. A semicircle of 10 m with a ring 0.15 of its radius survives 626 mm of spread, pushing a third harder at the end than at the start, and collapses only when the thrust reaches the outer edge of its springing.
The wheel on an arch that has spread
A masonry arch whose springings have moved apart still stands, and its thrust has risen. It has not grown stronger. A semicircle of 10 m span with a ring 0.15 of its radius carries 52.8 kN a metre on its quarter span before its springings move, and 29.8 kN at half the spread that would bring it down. A point load and a spread spend one reserve, the thrust the far springing can take, and the spread spends it first.
The slab holds what the shear centre lets it
A floor slab fixed along a girder's top flange holds a line, and the line is worth its distance from the shear centre. Over the supports of a fixed-ended 8 m span the slab raises the wide-topped girder's buckling moment by 43 per cent, the equal-flanged girder's fivefold and the wide-bottomed girder's fifteenfold — because the wide top flange drags the shear centre up to the slab, where holding it holds almost nothing. Under a uniform hogging moment the same slab is worth under a tenth to all three.
The round hole that hinges off its centreline
A circular hole in a beam's web is shallowest at its centreline and that is not where it fails. Cut the tees vertically all the way round and the first to yield is 35° round on the side towards the support; the mechanism's four hinges form 30° to 60° either side, wider for a small hole near a support than for a large one at mid-span. The design rule replaces the circle with a rectangle 0.45 of its diameter long and 0.9 deep — too short and too deep — and the two errors cancel to within two per cent along most of the span, but not beside a support, where the rule overstates a small hole by eleven.
The doubtful pier belongs in the middle of a pair
A viaduct's designer who knows which piers stand on poor ground can put a movement joint over each of them, and the joint helps: with either of two piers settling 40 mm, twelve spans grouped to put joints over them carry 315 kN·m where groups of three carry 367. Putting each doubtful pier in the middle of a two-span pair does far better, 230, because a pair's hogging is the thing a settling middle pier relieves. Under the full load, until its pier has sunk 35 mm, a pair is no worse than two simple spans, and it pays for that with the traffic envelope that groups of three were chosen for.
The second pier undoes the first
A truss continuous over one pier has its reaction set by one jack: lift until the load cell reads the design value, pack the bearing, done. Over three piers the jacks argue. Lifting one pier a millimetre hands 85 per cent of what it gains to the pier beside it, so jacking each pier to its own design reaction in turn leaves half the error after a full round and still a seventh after three. The error that will not go is the one the piers share, which lifting them all together barely moves. Read every pier once and solve for all the lifts together, and one round of the jacks does what ten rounds one at a time cannot.
The pier that may rise belongs under a joint
A pier that may only settle is best put in the middle of a two-span pair, whose hogging a settlement relieves before it adds to anything. A pier on swelling clay, or over a culvert that may be relieved of its fill, may rise instead, and then the pair is the worst place for it: 40 mm of heave puts 459 kN·m into a pair that would have carried 230 for the same settlement. The place that is gentle both ways is the end of a group, under a movement joint. With the doubtful piers' movement known in size but not in sign, joints over them carry 335 kN·m where pairs carry 459 and groups of three 465 — and nothing with the same traffic envelope does better.
The loop that sees only the end bolts
A friction joint's hysteresis loop below slip carries its clamp in it, so a gauge across a splice reading a small loop could in principle tell a loose bolt from a tight one. In a row of six it can tell only some of them. The plates between the bolts share the load so that the two end bolts carry 38 kN of a 120 kN cycle and the middle two 7, and a loop's width goes as the square of a bolt's force: the end bolts draw the loop, the middle ones barely touch it. One end bolt at half its clamp nearly doubles the loop; the third bolt at half changes it by a third of a per cent. Forty rows of scattered clamps read their end bolts' mean with a correlation of 0.99 and their weakest bolt's with 0.51.
The joint born holding a moment
A continuity joint over a pier ends its first thirty years sagged or hogged by the beams' creep and the slab's shrinkage, by an amount the date of the pour decides. Jacking the beams' pier ends before the joint is cast lets it be born holding the opposite moment, so that the two cancel at thirty years. The arithmetic works for any slab date. The jack does not, for two reasons: the beams' creep relaxes a jacked moment like every other restraint, so the jack must be two to three times the moment it cancels and is larger than the joint's cracking moment on either side; and a jack sized for one humidity is wrong by as much as the moment it removed at another. Held to what the joint can take uncracked, it cancels about half.