The slab holds what the shear centre lets it
Assumes The beam that fails sideways, The flange a slender web wants heavier and The point that is not in the section.
The weaker half sets the beam took 450 mm of 20 mm flange plate on a 600 × 10 mm web, divided it 300 over 150, and put the girder on an 8 m span under a moment that changes sign. The half whose narrow flange was compressed decided the beam, and the strong half lent it only a little through the twist the two halves share. The best division of the steel for any reversing moment turned out to be the plainest one: equal flanges. A span whose ends are held back by its neighbours, hogged at each support to twice its own sagging moment as a fixed-ended span is, buckled at a support moment of 746 kN·m with the wide flange on top, 1,392 with equal flanges and 1,670 with the wide flange underneath.
Every one of those girders had nothing on it. A continuous girder under a floor almost never stands like that. The slab, the decking or the precast planks sit on its top flange and are fixed to it, and over most of the span — the sagging middle — the top flange is the compressed one and cannot move sideways at all. Near the supports the top flange is in tension and the bottom flange is the compressed one, and the beam can still buckle there, by swinging its bottom flange sideways while it twists about the line the slab holds. The essay ended on that case: whether a slab on the wide top flange makes the narrow bottom flange’s hogging region as strong as an equal-flanged girder’s, or whether the restraint helps the equal girder more.
It helps the equal girder more, and by a factor that is not small. The reason is a single length — the height of the slab above the section’s shear centre — and the wide top flange spends almost all of it.
A twist about a line that cannot move
A section that buckles sideways moves in two ways at once: it displaces sideways by , measured at its shear centre, and it twists by . A fibre at height above the shear centre moves sideways by , so the top of the section and the bottom move by different amounts and the mode has a centre of rotation somewhere on the section’s axis of symmetry. The beam that fails sideways located that centre for a girder with nothing on it, a little below the tension flange.
A slab fixed along the top face at height above the shear centre forbids that face to move: everywhere along the span. The centre of rotation is no longer found by the beam; it is put there. The two freedoms become one, , and the energy of a small buckle, which for the free girder had a lateral bending term, a torsion term, a warping term, the coupling and the Wagner term , collapses into an integral in the twist alone:
Two things have happened in that substitution. The girder’s whole lateral bending stiffness has turned into extra warping stiffness, weighted by , because a section twisting about the slab line bends sideways by an amount proportional to its twist. And the coupling term now has a definite sign: a moment that compresses the held flange makes a stiffness, and only a moment that compresses the free flange can make it a softening. Under a uniform moment compressing the free bottom flange, a sine buckle over the span gives the critical moment in closed form,
with signed so that it is positive for the wide-topped section. The fixed-ended span is solved by writing the twist as a sine series of sixteen terms between fork supports and integrating each term against the real moment diagram, which hogs at the ends and sags in the middle. The series gives back the closed form for uniform moment, and with the restraint removed it gives back the free girders’ 746, 1,392 and 1,670 kN·m.
What the slab is worth with nothing beside it
Start with the case the brace on the wrong flange was about: a moment of one sign along the whole length, with the restraint on the tension flange. Over 8 m the slab raises the wide-topped girder’s critical hogging moment from 283 to 307 kN·m, the equal girder’s from 534 to 559, and the wide-bottomed girder’s from 1,018 to 1,027. At 4 m it adds under one per cent to any of them. That is the textbook result, and the calculation here agrees with it: a tension flange held sideways is a restraint at a point the mode was barely using, since the buckle of a girder in uniform moment already turns about a centre close to its tension flange.
The only place the slab begins to count in uniform moment is a long span. The closed form keeps the torsion constant over in its numerator at any length, while the free girder’s critical moment keeps falling as ; by 16 m the slab adds 39% to the wide-topped girder and 30% to the equal one. But spans of that length are where a girder’s hogging is least likely to be uniform, and the case worth computing is the one a continuous floor actually gives.
A middle that will not twist
The fixed-ended span hogs over its last 1.7 m at each end and sags between. With the slab holding the top face, the sagging middle has its compressed flange held, and it does something a free girder’s middle never does: it resists changing the twist. Every term in the energy that the moment drives through the restraint is a product of the twist with its own curvature or slope, and , and in the sagging middle both are stiffnesses. A twist that is the same everywhere in the middle costs nothing — the middle can rotate as a rigid body about the slab line, its bottom flange swinging sideways bodily — but a twist that bends or varies along the middle does cost, and the cost is proportional to .
So the mode is what the moment and the held line make it. The wide-bottomed girder twists most a fifth of the way in from each support, inside its hogging regions, and holds its middle down to half that; the middle acts as a clamp on the two hogging ends. The equal girder’s middle clamps less, sagging to 0.86 of the peak. The wide-topped girder’s middle hardly clamps at all: its buckle twists the whole span about the slab line in one smooth arch, very nearly the shape the free girder takes, and the slab has bought it only the difference between those two curves.
The clamp is the whole of the slab’s work, and it explains the uniform case backwards. A girder in uniform hogging has no sagging region to clamp anything, and its slab is left with only the extra warping stiffness , which over 8 m is worth a few per cent.
The worth of the restraint, by how hard the ends are held
The fixed-ended span is one point on a curve. The less the ends are hogged, the shorter the two hogging regions and the longer the clamping middle; at a hogging of a quarter of the span’s sagging moment each region is 0.4 m long, and the held girders could carry support moments of 9,700 kN·m and more before twisting — ten times what their steel can carry. At a hogging of 2 the regions are 1.7 m long and the three held girders buckle at 1,066, 7,083 and 24,482 kN·m, against 746, 1,392 and 1,670 free. At a hogging of 8, nearly uniform, the wide-topped girder’s gain has fallen to 4 per cent, and even the wide-bottomed girder’s has fallen to 31 per cent.
Read against the free girders, the figure reverses the advice of the essay before. Free, at a hogging of 2 the three divisions of steel sit within a factor of 2.2 of each other, and equal flanges are a fair choice wherever the moment changes sign. Held, they are a factor of 23 apart at a hogging of 2, and the order is set by one thing.
The height of the held line
As the beam that is a different beam upside down found, the shear centre of an unequal I-section sits towards its larger flange, at the point about which the two flanges’ sideways bending stiffnesses balance. A 300 mm flange is eight times as stiff sideways as a 150 mm one, so the wide-topped girder’s shear centre is 241 mm above the middle of its web — only 79 mm below the top face, where the slab sits. The equal girder’s is at mid-web, 320 mm below the slab. The wide-bottomed girder’s is 241 mm below mid-web, 561 mm below the slab.
Those three lengths are the restraint. The lateral stiffness the slab adds is and the clamp the sagging middle provides is proportional to , so a girder whose shear centre is almost at the slab gets almost neither. The figure moves the held line up and down the section to show it: held at its shear centre, the equal-flanged girder cannot buckle at all, because there is then nothing coupling its twist to its moment — no Wagner term, no lever between the held line and the centre of twist — and a pure twist under a bending moment needs one or the other. The wide-topped girder held at its own shear centre still buckles, at 959 kN·m, because its Wagner term softens it wherever its narrow flange is compressed; held anywhere between 40 and 180 mm above mid-web it is weakest of all, near 930, and the top face is barely better than the worst place to hold it.
The free girder of the essay before had its own lever arm in this story, unseen. Its buckle turned about a centre that the mechanics chose, below the tension flange, and the wide flange on top was what kept that centre near its own shear centre in hogging. Pinning the centre to the slab only helps when the slab is far from where the girder would have turned anyway.
Dividing the steel when a slab holds the top
Measured against the steel it carries rather than in kilonewton-metres, the division of the flanges decides whether buckling is a question at all. The first-yield moment in hogging is the smaller section modulus times the yield stress, 355 N/mm²: 918 kN·m for the wide top, whose narrow bottom flange yields first, 1,160 for equal flanges, 918 again for the wide bottom, whose narrow top flange now yields first in tension. Free, every division sits near that line: 0.81 of first yield for the wide top, 1.20 for equal flanges, 1.82 for the wide bottom. All three would be designed with a reduction for buckling.
Held, the 150 mm top over a 300 mm bottom buckles at 26.7 times its first-yield moment, a girder for which buckling sideways over its supports is simply not a mode. Equal flanges reach 6.1 times. The 300 mm top that was the stronger girder with its wide flange in compression reaches 1.16 — still a girder whose supports a designer must check for buckling — and a 350 mm top, its shear centre 24 mm from the slab, reaches 0.72 and is worse held than an equal girder is free. Every millimetre of flange moved from the bottom to the top costs stability once the slab is there, which is the opposite of the free girder’s best division.
This is the shape that composite bridge girders have, and it is not usually explained this way. A steel girder under a concrete deck is given a narrow top flange because the deck carries the compression in sagging and the top flange is needed only to hold the shear connectors and to carry the wet concrete during casting. Its bottom flange is wide because it carries the tension in sagging. The same proportions put the shear centre deep in the section, as far from the deck as it can be, so over the piers — where the bottom flange is compressed and the girder can buckle — the deck holds a line more than half the depth above the centre of twist, and the girder’s wide compressed flange is held as well as a slab can hold it. The proportions chosen for strength in the span are the proportions that make the deck a good restraint at the support.
Span by span
The span is the last variable, and it does not change the order. Shorter spans raise every girder; longer ones lower them. The wide-topped girder held by its slab reaches its first-yield moment before it buckles only up to a span of 9.3 m, and by 20 m it buckles at 0.53 of it. The equal girder still holds 1.32 at 20 m, and the wide-bottomed one 4.67 — a girder over which a slab-supported floor could be laid at almost any span without a buckling check over its supports, if the section stays its shape.
Which body was cut, and which equation gave the number
Every number above comes from the twist of one span between two supports, each a fork that stops the section twisting and moving sideways and leaves it free to warp and to turn in plan. The span is the free body; the moment along it is the uniformly loaded span’s own diagram with end moments set by the hogging ratio, a parabola from the support moment through zero at 0.21 of the span from each end, for a hogging of 2, to the sagging moment at mid-span. The section’s stiffnesses are those of the welded plate girder: from the two flanges’ sideways bending, from the thin-plate sum , from the two flanges’ bending about the web, and from the integral of over the section.
The slab is a constraint and nothing more: a line at the top face held against sideways movement everywhere, with no stiffness against the section rotating about that line. The energy is minimised over twist shapes that satisfy it, the resulting eigenvalue problem gives the moment factor, and the factor times the diagram’s largest moment gives the critical moment. For the wide-topped girder in uniform hogging, the hand calculation goes: , mm, so against ; with the bending part of the numerator is and ; over mm the moment is 307 kN·m. The equal girder has and , so its denominator is 640 mm and its is twelve times larger. That ratio is the whole of the uniform-moment comparison, and the clamp the sagging middle provides scales with the same .
What the rigid section leaves out
The calculation holds every cross-section rigid: the web stays straight between the flanges, and the bottom flange can only move sideways by the section rotating about the slab line. In a real girder the web bends, and with the slab holding the top flange the bottom flange has a second way to go, swinging sideways on a web that flexes — lateral–distortional buckling, the mode a row of frames is not a foundation and the buckle that will not spread out treat for a half-through girder’s compression chord. When the slab also clamps the top flange against rotation, as shear connectors and a thick deck do, the rigid twist is forbidden altogether and distortion is the only mode left.
A bound on it is a short calculation. The 10 mm web, a plate cantilevering 600 mm down from a clamped top flange, resists a sideways push at its bottom with a stiffness of , about 0.27 N/mm per millimetre of length. The 150 × 20 mm bottom flange on that foundation, as in held everywhere, and it forgets its length, buckles over a long half-wave at , 1,120 kN, a stress of 374 N/mm² — just above the yield stress. The 300 mm bottom flange reaches 530 N/mm². For these sections the distortional mode does not overturn the order, and the wide-bottomed girder stays the one buckling cannot reach. With an 8 mm web the narrow flange’s bound falls to 268 N/mm², below yield, and the rigid section’s 1,066 kN·m is no longer an answer. The hogging regions here are shorter than the long half-wave, 4.6 m for the narrow flange, which raises the distortional load above that bound; the bound is where a calculation would start, not where it would end.
Nor is the slab’s grip on the girder modelled. Shear connectors that can slip, decking fixed by screws at intervals, and planks that merely rest on the flange all hold the top face less than completely, and each is a spring rather than a constraint. The brace on the wrong flange showed that a restraint’s stiffness is worth almost all of its ideal value at quite modest sizes, but it showed that for discrete braces; a continuous spring along the flange, whose stiffness is set by the connector spacing, has not been computed here.
The supports are forks, which is generous at an internal support where the bottom flange is compressed and held, if at all, only by a bearing stiffener and the web above it — the inverted U-frame of composite bridge practice. A support whose bottom flange can move sideways a little lets the hogging region buckle into it, and the clamp in the middle cannot reach across the support to help.
Where the restraint is drawn from
The calculation sharpens a habit of thought that is easy to state loosely. Restrain the compression flange is the rule for bracing, and it is right: a brace near the centre of twist does nothing. Three braces where the moment is put a few discrete restraints where they count most; what a slab on the tension flange of a hogging region does is not bracing in that sense. It moves the centre of twist to the slab, and the girder then has to buckle about a centre it would not have chosen — paying in lateral bending stiffness, weighted by the square of the distance from its own shear centre, and in the resistance of its sagging neighbours to any change in twist, weighted by that distance once. Whether that is worth anything depends entirely on the distance.
The wide-topped girder has spent the distance on strength in sagging. Its 300 mm top flange gave it a critical moment nearly twice the equal girder’s with the wide flange compressed, which is the reason such sections are used as crane girders and as beams carrying point loads on their top flanges. Under a floor, the same proportions are the worst choice over the supports: the slab sits 79 mm from its shear centre, the girder’s middle can barely clamp its ends, and the support region buckles at 1.16 times first yield where an equal girder made of the same steel would reach 6.1. The weaker half still sets the beam; what the slab changes is which half is weaker, and by how much the other can help.
Still open: the slab that clamps the flange against turning
The slab here holds a line and lets the section turn about it. A deck cast around shear connectors does more: it holds the top flange against rotation as well, so that the rigid twist is gone and only the web’s bending lets the bottom flange move. The hogging region then buckles as a flange on a flexible web, with the sagging middle clamping it through the web’s stiffness rather than through the twist, and the sixteen-term series in twist would have to become a series in the web’s sideways bending as well. Whether the order found here — wide bottom far ahead, equal flanges next, wide top last — survives once the web is allowed to bend, and how thin a web has to be before the middle’s clamp is lost through its flexibility, needs the section to be divided into a flange and a plate rather than treated as one rigid shape.
Named alongside this one
Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.
- The load that moves with the twist lateral-torsional buckling · shear centre
- The most dangerous day is before it is finished lateral restraint · lateral-torsional buckling
The objects this essay names
Each one links to every other essay that touches it.
Continuous beamFirst yieldLateral restraintLateral-torsional bucklingMonosymmetricShear centreU-frameWagner effect