The weaker half sets the beam
Assumes The beam that fails sideways, The shape of the diagram, and not its peak and The flange a slender web wants heavier.
The beam that is a different beam upside down took 450 mm of 20 mm flange plate, divided it 300 over 150 between the top and the bottom of a 600 mm web, and put the girder on an 8 m span in uniform moment. With the wide flange in compression the beam buckled sideways at 1,018 kN·m; with the narrow flange in compression, at 283. The same steel divided equally gave 534 either way. The difference is the Wagner term, a property of an unequal section that a symmetric one does not have: when a section twists every fibre leans, and the leaning of a compressed fibre adds a torque that resists the twist when the compressed fibres are far from the centre of twist and helps it when they are near.
That essay held the moment uniform, because uniform moment is the case with a closed form. It ended on the case that has none. A real girder rarely carries one moment along its whole length. A beam with a moment applied at one end, a span whose ends are held back by its neighbours, a cantilever’s back span: each has a moment that changes along the beam, and often one that changes sign, so that the wide flange is compressed in one part of the span and the narrow flange in another. A symmetric beam does not care which flange is compressed. An unequal one cares a factor of 3.6, and in double curvature it gets both factors at once, in different halves of the same beam.
The question is whether the half that is strong can hold up the half that is weak through the twist they share, and whether the factor that every design method applies to a varying moment knows anything about it.
A sign inside an integral
The beam that fails sideways set out what buckling sideways is: under a large enough moment, a beam that has been bending in its stiff plane finds a neighbouring shape, displaced sideways by and twisted by , that it can hold with the same moment, and the moment at which that shape first exists is the critical moment. The neighbouring shape is found by asking when the energy of a small and stops being positive. Four terms are stiffness: the lateral bending , the St Venant torsion , the warping that the section that cannot stay flat described. One term couples the two motions, , because a twisted beam bends its bending moment partly into the weak plane. A symmetric beam stops there.
An unequal beam has one term more, . It is a torsional stiffness, as is, but the moment supplies it, and its sign is the sign of the moment times the sign of . With the wide flange compressed the product is positive and the moment stiffens the section against twist; with the narrow flange compressed it is negative and the moment softens it. In uniform moment the product is the same everywhere and comes out of the integral as a constant, which is why the uniform case has a formula. When the moment varies, the product varies with it, and where the moment changes sign the Wagner term changes from a stiffness to a softening part way along the beam.
So the calculation here keeps both freedoms, writes each as a sine series of fourteen terms between fork supports, which hold the twist and the sideways movement at the ends but let the ends warp and turn in plan, and integrates every term against the actual moment. The answer is an eigenvalue problem whose smallest positive root is the critical moment as the diagram is drawn and whose smallest negative root is the critical moment with the diagram turned over. In uniform moment the series is exact in one term and gives back 1,018 and 283 kN·m to the newton-millimetre. With equal flanges, where the Wagner term vanishes, it gives back the moment-gradient factors that the shape of the diagram, and not its peak found by a different route, eliminating the lateral deflection and solving for twist alone: 1.84 for a moment at one end and 2.73 in double curvature. The two calculations share no code and agree to the third figure.
The far end turns round
The moment is linear along the span, the full value at the left end and at the right, so ψ = 1 is uniform moment, ψ = 0 a moment at one end only and ψ = −1 double curvature, with the two ends equal and opposite. The upper curve has the wide flange compressed at the left end, where the moment is largest. The lower curve is the same diagram turned over, the narrow flange compressed at the left end. Between ψ = 1 and ψ = 0 both behave much as a symmetric beam would: as the moment falls away from the left end the beam has less of its length near the peak, and the critical value of the peak rises. The wide flange’s sense rises from 1,018 to 1,849 kN·m, a factor of 1.82; the narrow flange’s from 283 to 505, a factor of 1.79. A symmetric beam’s factor over the same range is 1.84.
Past ψ = 0 the right-hand end of the beam begins to hog the other way, and its moment compresses the other flange. For the lower curve that is the wide flange, so the far end now stiffens the beam, and the curve keeps rising. For the upper curve it is the narrow flange. The upper curve keeps climbing for a while, because the far end’s moment is still small, and peaks at 2,151 kN·m near ψ = −0.35. Then it turns down, and falls steeply: by ψ = −1 it is at 863, less than half its peak. The lower curve rises to meet it, and at ψ = −1 they are one number, since a beam in double curvature turned over is the same beam reflected end for end.
The equal-flanged beam, drawn dashed, has no such turn. Its critical moment rises all the way to ψ = −1, where it is 1,455 kN·m, 2.73 times its uniform value. At that point the unequal beam, which under uniform moment was 91 per cent stronger than the equal one in its good sense, is 41 per cent weaker in both.
The factor that reads only the diagram
Every design method for lateral-torsional buckling treats a varying moment by a factor on the uniform-moment value. The formula that reads four numbers examined the American quarter-point form, which reads the moment at the ends and quarter points of a segment and nothing about its section; Eurocode 3’s factor is read from the moment diagram in the same way. For a symmetric beam that is legitimate, because the diagram is the only thing that varies. For an unequal beam the obvious use is to take the uniform-moment value for whichever sense the larger moment has, and multiply.
With the wide flange compressed at the heavier end, that product is the upper dashed line, and as long as the far end’s moment has the same sign it tracks the true value closely: at ψ = 0 it gives 1,875 kN·m against 1,849, 1.4 per cent high. The narrow flange’s sense does slightly worse, 521 against 505, 3 per cent high, and the reason is worth noticing before it is overtaken by a larger one. The Wagner term in that sense is a softening, and the softening is proportional to the moment, not to its square. A gradient factor works because the square of a diagram that falls away from its peak is much smaller than the square of a flat one. A term that is linear in the moment is reduced less by the same falling away, so a factor calibrated on squares over-credits the gradient whenever the linear term is working against the beam.
Then the far end turns round, and the product loses touch with the beam altogether. At ψ = −1 it gives 2,775 kN·m for a beam that buckles at 863: more than three times too high. Nothing in the diagram warns of it; the diagram of a beam in double curvature looks the same whichever way up the section is fitted. The only way to read the beam correctly from its diagram is to know which flange each part of the diagram compresses.
The lower dashed line is the other product, the symmetric factor times the uniform value with the narrow flange compressed — the weaker of the two uniform numbers. At ψ = −1 it gives 771 kN·m against the true 863. That is the question this essay set out to answer, and the answer is a number: in double curvature the half of the span that compresses the wide flange lends the half that compresses the narrow one 12 per cent. The beam is a little better than its weaker half would be alone in uniform moment with the usual credit for gradient, and a long way short of what its better half suggests.
Where it twists
The buckled shape says the same thing in a picture. A symmetric beam in double curvature twists symmetrically, its largest twist at mid-span, because its two halves are mirror images in everything that matters. The unequal beam at ψ = −0.25 twists nearly as a single half-wave too, its largest twist just right of centre, since its far end’s reversed moment is still small. At ψ = −1 the shape has moved: the largest twist is at 0.68 of the span, well into the half where the narrow flange is compressed and the Wagner term is a softening. The left half, which is in its good sense, twists much less and acts as an elastic restraint on the right half, the way a stiff adjacent segment restrains a weak one in a braced beam.
That is the mechanism of the 12 per cent. The two halves cannot buckle separately, because the twist is continuous across the point of contraflexure, so the right half’s buckle has to drag the left half’s twist with it, and the left half resists. But the left half only restrains the right half’s end, and a restraint at one end of a buckle is worth less than the stiffness in its middle. The mode puts its effort where the beam is softest.
How much the stronger half lends
The 12 per cent belongs to an 8 m span. The share of the critical moment that comes from warping and from St Venant torsion changes with span, and so does the share that comes from the Wagner term, which in a moment of given size is a fixed fraction of the section’s depth.
On a short span the stronger half’s help is large: 37 per cent at 3 m. Short beams buckle against their warping stiffness, which acts on the curvature of the twist, and a half-wave that tries to concentrate in one half of the span pays heavily in warping for doing so. The strong half restrains it efficiently. As the span grows, warping matters less and the Wagner term, which acts on the twist’s rate, matters more; the help falls to 12 per cent at 8 m and 2 per cent at 12 m, and past about 14 m it is negative. At 20 m the beam buckles at 97 per cent of the symmetric factor times its weak uniform value. The weak-sense product, which looked like a safe lower bound at 8 m, is not a bound at all on a long span.
The second line on the figure is the unequal beam against equal flanges with the same steel, both in double curvature. It is below one at every span: 0.49 at 3 m, 0.59 at 8 m, 0.78 at 20 m. Dividing the flange steel unequally never helps a beam in double curvature, and on short spans it halves its resistance.
The best division for a moment that reverses
The beam that is a different beam upside down found that a moment which reverses in time — first one way and then the other, as wind does — is best served by equal flanges, because the beam must be good in its worse sense and the worse sense is best at symmetry. A moment that reverses along the span is a different thing, since both senses act at once on different parts of the beam, and it might have had a different best division. A wide top flange over a span that is mostly sagging and a little hogging seems the natural design.
It has the same best division. In double curvature the critical moment is symmetric in the division, since turning the beam over is the same as reflecting it, and its single peak is at equal flanges, 1,455 kN·m; the 300 mm flange gets 863 and a 350 mm flange 510. A moment at one end only that may act either way peaks at equal flanges too, at 983 against 505 for the 300 mm flange. Every case in which the narrow flange is compressed anywhere that matters falls fastest as the division becomes unequal, because the softening grows with the Wagner term while the stiffening it buys on the other side is a factor on a moment that is already high. The weak region sets the beam, and the weak region is weakest when the steel has been moved out of it.
A span whose neighbours hold its ends
The commonest moment that changes sign along a beam is not a moment applied at its end. It is a continuous beam under gravity: each span sags in the middle and hogs over its supports, where the moment over the support was first drawn. In a fixed-ended span under a uniform load the ends hog by and the middle sags by , so the hogging is twice the sagging, and the region near each support, a little over a fifth of the span, compresses the bottom flange.
The figure measures each case by the load it can carry: the free moment at which the span buckles, whatever its ends do with it. For equal flanges continuity helps steadily. With free ends the span buckles at a free moment of 604 kN·m; with fixed ends, at 2,088, three and a half times as much, because the peak moment is now lower for a given load and the moment diagram has a shape whose square is small.
The unequal beam with its wide flange on top starts ahead: 857 kN·m with free ends, 42 per cent more than equal flanges, since a simply supported span under gravity compresses only the wide flange. As its ends are hogged it gains, but not for long. Its free moment at buckling reaches 1,185 at an end hogging equal to the span’s sagging moment and then falls, to 1,119 with fixed ends and 1,007 at a hogging of three. At fixed ends it carries 54 per cent of what equal flanges carry. The section that was chosen because the span sags has made the span weaker as soon as the span is continuous.
The beam the other way up, or the same beam under uplift, does the reverse. With the narrow flange compressed in the middle it starts at 418 kN·m, and as its ends hog they compress its wide flange and stiffen it; at fixed ends it carries 2,504, more than equal flanges do. For a continuous beam under gravity, the flange that the supports compress is the one to make wide.
The ends weigh more than they look
The hogged ends cover a little over a fifth of a fixed span each, and their moment is larger than the span’s, but by a factor of two and not of four. That they decide the beam needs a second reason, and the energy integral holds it.
The two moment terms weigh the moment against different things. The coupling term, which every beam has, is , and in the buckled shape follows the twist, so the moment is weighted by where the beam twists — mostly in the middle, where a fork-supported buckle has its crest. The Wagner term is , so the moment is weighted by where the twist changes fastest, and between fork supports that is at the supports, where the twist is zero and climbing. In the fixed span the outer fifths hold 82 per cent of the rate of twist’s weight and 11 per cent of the twist’s.
For a symmetric beam that does not matter, since it has no Wagner term and its end moments are weighted by the small twist there. For the unequal beam it is the whole story. The hogged ends compress the narrow flange exactly where the Wagner softening is weighted most heavily, so the region of the beam that a gradient factor discounts, because the twist is small there, is the region in which the unequal beam loses its stiffness. The flange that swings is in tension found the same inversion at a cantilever’s tip: the part of a beam where nothing seems to happen is where the restraint matters.
The assumptions under the numbers
Every number here is the elastic critical moment of a perfect beam: no initial twist, no residual stress, no yield. A design resistance is reached through a reduction curve that starts from this number, and the reduction is larger for more slender beams, so a factor of two in the critical moment is less than a factor of two in what the beam can carry. The comparison between senses survives the reduction; the absolute numbers do not.
The loads act at the shear centre, so the height of the load, which the load that moves with the twist showed to be worth a large share of a beam’s capacity, is left out. In an unequal section the shear centre sits close to the wide flange, so a gravity load on the top flange of the beam with its wide flange on top is applied only a little above it, and the load-height penalty is smaller than for a symmetric beam of the same depth. On the beam the other way up it is larger.
The supports are forks. A continuous beam’s internal support is usually much better than that against twist, since the beam is framed into a column or sits on a stiffened bearing, and usually worse against the bottom flange moving sideways, since nothing holds the compressed bottom flange at a support except the web, which can distort. When the web distorts the bottom flange buckles on its own, restrained only by the web’s bending, and the cross-section’s shape does not stay rigid as this calculation requires. That is the inverted U-frame of a composite bridge girder and the reason a hogging region is often checked as a strut on an elastic foundation rather than as a beam. Where the section distorts, the unequal beam’s hogging region is weaker than the number here.
Nor are the supports braced along the span. Three braces where the moment is found that a few restraints placed where the moment is largest change a beam’s buckling more than any factor; and the brace on the wrong flange found that a brace on the tension flange does almost nothing. In a hogging region the tension flange is the wide top flange of this girder, which is exactly where a floor would brace it.
What a factor on a diagram can carry
A moment-gradient factor encodes one fact about a beam: the distribution of its moment along its length, weighted by the shape it buckles into. For a symmetric section that is all there is to know. For an unequal section the factor needs a second fact, which flange each part of the diagram compresses, and it is not a correction to the first. In double curvature it is the dominant effect, worth a factor of three on the critical moment, and the factor that ignores it errs in the dangerous direction for the sense that looks favourable.
What the beam does is simple to state. Its weaker region sets it, and its stronger region lends it a little through the continuity of the twist — 37 per cent on a short span, 12 per cent on an 8 m one, nothing on a long one. The Wagner term weights the moment by the rate of twist rather than the twist, which is why a weak region near a support, where a gradient factor finds nothing to count, can still decide the beam. And the division of steel that does best in every case where the moment changes sign is the plainest one: equal flanges.
Still open: the beam braced on the flange that is not compressed
A continuous girder under a floor is held along its top flange by the slab. Over most of the span that is the compressed flange and the beam cannot buckle there at all; near the supports it is the tension flange, and the beam can still buckle by twisting about the restrained top flange, with the bottom flange swinging sideways. That is a different problem from the one solved here, since the centre of twist is fixed at the top flange rather than free to find the shear centre, and the Wagner term is measured about the wrong point. For a girder with a wide top flange held by a slab and a narrow bottom flange in compression over the support, whether the restrained top flange makes the narrow bottom flange’s hogging region as strong as an equal-flanged girder’s, or whether the restraint helps the equal girder more, needs the energy integral rewritten about an enforced axis of twist and a moment that changes sign along it.
Named alongside this one
Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.
- The braces that stay where the framing puts them critical moment · lateral-torsional buckling · moment gradient · warping
- The restraint that beats the gradient lateral-torsional buckling · moment gradient · warping
- Twice the moment, four times the brace critical moment · lateral-torsional buckling · warping
- The root that belongs to the column lateral-torsional buckling · warping
- The slip that peaks where the moment turns continuous beam · contraflexure
- The stiffness a row of braces shares out critical moment · lateral-torsional buckling
What links here
Every essay whose body links to this one.
The objects this essay names
Each one links to every other essay that touches it.
Continuous beamContraflexureCritical momentLateral-torsional bucklingMoment gradientMonosymmetricWagner effectWarping