Connections

The loop that sees only the end bolts

A friction joint's hysteresis loop below slip carries its clamp in it, so a gauge across a splice reading a small loop could in principle tell a loose bolt from a tight one. In a row of six it can tell only some of them. The plates between the bolts share the load so that the two end bolts carry 38 kN of a 120 kN cycle and the middle two 7, and a loop's width goes as the square of a bolt's force: the end bolts draw the loop, the middle ones barely touch it. One end bolt at half its clamp nearly doubles the loop; the third bolt at half changes it by a third of a per cent. Forty rows of scattered clamps read their end bolts' mean with a correlation of 0.99 and their weakest bolt's with 0.51.

Assumes The joint that carries nothing until it slips and The force that is whatever it needs to be.

The joint that hides its clamp in its loop looked inside one bolt of a friction joint below slip. A preloaded bolt clamps the plates over a patch whose pressure falls to nothing at its edge, so a shear load smaller than the slip load cannot be carried by sticking everywhere: the edge of the patch slips first, the slipped annulus grows inward with the load, and the whole patch slides only at μN\mu N. That is Cattaneo’s and Mindlin’s partial slip, and its two consequences pulled in opposite directions. The joint’s stiffness under a small load is the stuck patch’s, 8aG∗8aG^*, 3.81 kN/µm for these bolts, and it has no clamp in it: a bolt at half its preload is exactly as stiff, to begin with, as one at full. But a cycle of load opens a small loop whose width grows as Q2/μNQ^2/\mu N, and that does carry the clamp. A gauge good to 0.05 µm could tell a full clamp from a half one under a cycle of ±8.9 kN.

That was one bolt. A real splice is a row of them, and the essay ended on the question that a row asks: whether a measured loop can be read back into the weakest bolt’s clamp. In a row the bolts do not share the load equally — they are joined by plates that stretch — and each bolt’s contact slips partially at its own load and its own clamp, so the loop is a sum of six loops that the plates have weighted. Which bolts the weighting favours is the whole of the answer.

Six bolts and two plates that stretch

The splice is a lap of two plates, 140 mm wide and 15 mm thick, joined by six M24 bolts in a line at a 70 mm pitch, each preloaded to 172 kN with a slip factor of 0.5 — a clamp a shear load leaves alone, unlike the tension joint of the force the bolt never saw applied, whose clamp the load itself changes: a slip load of 86 kN a bolt, 516 kN for the row. Plate A is pulled at its far end and plate B the other way at its far end, and between bolts ii and i+1i+1 plate A carries the forces the bolts before it have passed across and plate B carries the rest. Each bolt passes a force qiq_i against a slip sis_i between the plates at its station, and the plates’ stretch between stations sets how the slips differ:

si+1=si+∑j≤iqjk−Q−∑j≤iqjk,k=E b tp,s_{i+1} = s_i + \frac{\sum_{j\le i} q_j}{k} - \frac{Q - \sum_{j\le i} q_j}{k},\qquad k = \frac{E\,b\,t}{p},

kk being one pitch of plate. Each bolt’s force is its own contact’s: on first loading q=f−1(s)q = f^{-1}(s), Mindlin’s curve, and on the way back from its own peak the Mindlin–Deresiewicz branch, so each bolt remembers its own turning point. The row is solved by guessing the first bolt’s slip and walking along the row until the forces add up to the applied load.

A gauge across the splice reads the elongation between the two pulled ends — the first bolt’s slip plus plate A’s stretch over the row — and the loop it draws is the subject of the figures. The model is a line of bolts in two plates of equal stiffness, which is a lap splice or one half of a symmetric double-cover splice; the plates are elastic and the bolts’ shanks do not bear.

The loop a splice draws

A splice's loop, and the one loose bolt it can show. The loop a gauge across a lap splice of six bolts at a 70 mm pitch in two 140 by 15 mm plates, each bolt clamped by 172 kN with a friction of 0.50 draws under a cycle of ±120 kN, drawn as the reading less the tight row's straight line, so that only what is not elastic shows: all six tight, the end bolt at half its clamp, and the third bolt at half. Its width at no load is 0.710 µm tight, 1.381 with the end bolt loose and 0.712 with the third.
Fig. 1 The loop a gauge across the splice draws under a cycle of ±120 kN, drawn as the reading less the tight row’s straight line, so that only what is not elastic shows: all six tight, the end bolt at half its clamp, and the third bolt at half. Its width at no load is 0.710 µm tight, 1.381 with the end bolt loose and 0.712 with the third.

The plates’ elastic stretch is most of the reading — a load of 120 kN moves the gauge by 59 µm, of which the hysteresis is about one — so the figure subtracts the straight line the tight row follows on first loading and shows what is left. What is left is a loop, the six contacts’ hysteresis summed, 0.710 µm wide at no load for a tight row. With the first bolt at half its clamp the loop is 1.381 µm wide, very nearly double. With the third bolt at half instead it is 0.712.

The same bolt with the same lost preload changes the loop by 95 per cent at one end of the row and by a third of a per cent in the middle. Nothing about the third bolt is different except where it stands.

Which bolts carry the load below slip

Which bolts of a splice carry its load below slip. The force each bolt passes from plate to plate at the peak of a ±120 kN cycle on a lap splice of six bolts at a 70 mm pitch in two 140 by 15 mm plates, each bolt clamped by 172 kN with a friction of 0.50, all six tight and with the first at half its clamp; dotted, each bolt's slip load. Tight, the bolts carry 38.2, 14.9, 6.9, 6.9, 14.9, 38.2 kN; with the first at half, 36.2, 16.2, 7.4, 7.1, 15.0, 38.2.
Fig. 2 The force each bolt passes from plate to plate at the peak of a ±120 kN cycle, all six tight and with the first at half its clamp; dotted, each bolt’s slip load. Tight, the bolts carry 38.2, 14.9, 6.9, 6.9, 14.9 and 38.2 kN; with the first at half, 36.2, 16.2, 7.4, 7.1, 15.0 and 38.2.

This is the classical shape of a bolted row, and below slip it has a reason particular to friction joints. Every stuck contact has the same stiffness, 8aG∗8aG^*, whatever its clamp, so before any bolt is near its slip load the row behaves as six identical springs joined by plates, and the load goes where a row of identical fasteners always sends it: to the ends. The first bolt sees the whole load in one plate and nothing in the other, so the slip between the plates is largest there; the middle bolts sit where the two plates carry half each and stretch alike, so the slip, and the force, are least. With these proportions the two end bolts carry 64 per cent of the load between them, the middle two 12 per cent.

The loose bolt hardly changes that. At half its clamp the first bolt still carries 36.2 kN of the 120, against 38.2 tight, because its stiffness is unchanged; it has given up two kilonewtons only because, at 36 of its 43 kN slip load, it has begun to soften. A friction row below slip shares its load by its contacts’ geometry, which has no clamp in it, so a loose bolt keeps its share until it is nearly slipping. Measuring the shares — by strain gauges between the bolts, say — would not find it.

The long joint, before anything bears

The shape itself is not new. The bolt that carries more than its share found it for bolts in bearing: along a lap the fasteners’ forces follow a hyperbolic cosine with its least value in the middle, because the plates’ stretch makes the slip between them largest at the ends, and the longer the joint the more the ends carry. What is particular to a friction joint below slip is the stiffness in that argument. For bolts in bearing it is the shank’s and the hole’s, which the bolt’s diameter and the plate’s thickness set; here it is the stuck contact’s, 8aG∗8aG^*, which nothing but the patch’s size and the steel’s shear modulus sets. The parameter that decides how steeply the cosine rises — the contact’s stiffness against one pitch of plate, 2k0/k2k_0/k, about 1.2 on this splice — is therefore the same for every bolt in the row however unevenly they were tightened, and the distribution is the tight row’s until some contact nears its own slip load.

That makes the friction row a cleaner case of the long joint than the bearing row, and a less forgiving one for inspection. In bearing, a bolt that is loose in its hole carries less until the joint has moved enough to bring it into contact, so a defect redistributes load and could in principle be seen in the sharing. Below slip a loose friction bolt is not loose in any sense the plates can feel. Its defect is held entirely in a property — the clamp — that enters only the second-order part of its response, and only the loop is second-order.

Why the loop is drawn by the end bolts

The loop’s width is a different matter, because it is not linear in a bolt’s force. For one contact cycled by ±q\pm q well below slip the width at no load is, to leading order,

w≈q26 k0 μN,w \approx \frac{q^2}{6\,k_0\,\mu N},

k0=8aG∗k_0 = 8aG^* being the stuck stiffness — the first essay’s small-load result. A bolt’s contribution goes as the square of its force over its clamp. The end bolts carry 38.2 kN and the middle ones 6.9, so the end bolts’ loops are (38.2/6.9)2≈31(38.2/6.9)^2 \approx 31 times as wide as the middle bolts’ at the same clamp. Of a tight row’s loop, the two end bolts draw about 85 per cent, the next two about 13, and the middle two about 3.

That makes the arithmetic of the loose bolts almost obvious. Halving the end bolt’s clamp doubles its own loop, which was 42 per cent of the total, and because it is now near enough to its slip load that the leading-order term is no longer the whole of its loop, its contribution more than doubles: the row’s width goes up by 95 per cent. Halving the third bolt’s clamp doubles a contribution of about one per cent. The loop is a census of the bolts weighted by the square of the load each carries, and in a row of friction bolts the load each carries is fixed by where it stands.

Which bolt is loose, as the loop sees it

Which bolt is loose, as the loop sees it. The width of the loop of a lap splice of six bolts at a 70 mm pitch in two 140 by 15 mm plates, each bolt clamped by 172 kN with a friction of 0.50 with one bolt at half its clamp, over the width with all six tight, against which bolt it is, under cycles of ±60 and ±120 kN. At ±120 kN the ratio is 1.95, 1.03, 1.00, 1.00, 1.03, 1.95 from the first bolt to the sixth.
Fig. 3 The width of the loop with one bolt at half its clamp, over the width with all six tight, against which bolt it is, under cycles of ±60 and ±120 kN. At ±120 kN the ratio is 1.95, 1.03, 1.00, 1.00, 1.03 and 1.95 from the first bolt to the sixth.

The figure moves the loose bolt along the row. At the ends it nearly doubles the loop; one bolt in from the ends it adds three per cent; in the middle it adds nothing a gauge could see. A smaller cycle, ±60 kN, gives the same shape at a lower level, the end bolt raising the loop by about 60 per cent: at a smaller load the end bolt is further from slip and its loop closer to the leading-order term, whose ratio for a halved clamp is exactly two on that bolt’s share.

The first essay’s measurement argument carries over with a different meaning. A gauge good to a few per cent of the loop’s width — 0.02 µm at ±120 kN on this row — can tell a tight row from one with a loose end bolt with room to spare. It cannot tell a tight row from one with a loose bolt anywhere in the middle four, and it cannot tell which end the loose bolt is at, because the row is symmetric.

The loop against the cycle

The loop's width against the cycle, for four rows. The width at no load of the loop of a lap splice of six bolts at a 70 mm pitch in two 140 by 15 mm plates, each bolt clamped by 172 kN with a friction of 0.50, against the cycle's amplitude on the row, all tight, the end bolt at half, the third at half, and all six at half. At ±60 kN, 0.153, 0.249, 0.154, 0.355 µm; at ±120, 0.710, 1.381, 0.712, 2.146.
Fig. 4 The width at no load of the row’s loop against the cycle’s amplitude, all tight, the end bolt at half, the third at half, and all six at half. At ±60 kN, 0.153, 0.249, 0.154 and 0.355 µm; at ±120, 0.710, 1.381, 0.712 and 2.146.

The loop grows with the square of the cycle while every bolt is well stuck, and a little faster than that as the end bolts begin to approach their slip loads. Two features of the figure matter for reading a measurement. The first is that the third-bolt-loose line lies on the tight one at every amplitude; there is no cycle large enough to make the middle of the row visible before the end bolts slide. The second is that the all-loose row is not twice the tight row but three times it at ±120 kN: half the clamp on every bolt halves every slip load, so the end bolts are at 38 of their 43 kN and deep into the nonlinear part of Mindlin’s curve. A loop’s width is an ambiguous reading for that reason — a wide loop may be one loose bolt near slip or six loose bolts far from it, and the amplitude at which the loop is taken decides which.

In a longer row the middle disappears

In a longer row the middle bolts disappear from the loop. The width of the loop with one bolt at half its clamp over the width with every bolt tight, against the number of bolts in the row, the cycle ±20 kN for every bolt: the end bolt loose, and the middlemost. With two bolts, 1.69 and 1.69; with six, 1.95 and 1.00; with ten, 4.34 and 1.00.
Fig. 5 The width of the loop with one bolt at half its clamp over the width with every bolt tight, against the number of bolts in the row, the cycle ±20 kN for every bolt: the end bolt loose, and the middlemost. With two bolts, 1.69 and 1.69; with six, 1.95 and 1.00; with ten, 4.34 and 1.00.

The longer the row, the more of its load goes to its ends, and the more completely its middle bolts drop out of the loop. A row of two has no middle, and either bolt at half raises the loop by 69 per cent. In a row of six the middle bolt is invisible. In a row of ten it is still invisible, while the end bolt, carrying so large a share of a load that has grown with the row that it is close to slip at half its clamp, raises the loop more than fourfold. The bolts a loop can see are the two at the ends and, faintly, their neighbours, whatever the length of the row.

That is uncomfortable for exactly the joints where inspection matters. A long friction splice in a bridge’s flange has a dozen bolts in a line, and the middle ten are the ones whose preload nobody can check by a loop.

A loop reads the end bolts’ clamps, not the weakest bolt’s

A loop reads the end bolts' clamps, not the weakest bolt's. Forty rows of six bolts whose clamps scatter uniformly within 20 per cent of 172 kN, cycled by ±120 kN: each row's loop width over the nominal row's, against the mean clamp of its two end bolts and against its weakest bolt's clamp, both over the nominal. The width's correlation with the inverse of the end bolts' mean is 0.99; with the inverse of the weakest's, 0.51.
Fig. 6 Forty rows of six bolts whose clamps scatter uniformly within 20 per cent of 172 kN, cycled by ±120 kN: each row’s loop width over the nominal row’s, against the mean clamp of its two end bolts and against its weakest bolt’s clamp, both over the nominal. The width’s correlation with the inverse of the end bolts’ mean is 0.99; with the inverse of the weakest’s, 0.51.

The last figure turns the question round, to what an inspector actually has: a splice whose bolts were tightened by a procedure with a known scatter, and one loop. Forty rows are drawn with each clamp scattered uniformly within 20 per cent of the nominal. Each row’s loop width is plotted twice, once against the mean clamp of its two end bolts and once against its weakest bolt’s clamp. Against the end bolts the points fall on a line; against the weakest they are a cloud. The correlation of the width with the inverse of the end bolts’ mean clamp is 0.99, and with the inverse of the weakest bolt’s 0.51 — and even that 0.51 is mostly the cases where the weakest bolt happens to be at an end.

A measured loop can be read back into a clamp, but it is the end bolts’ mean clamp, and nothing else. The question the first essay left — whether a loop can be read into the weakest bolt’s clamp — has a definite answer, and it is no. What the loop gives is better than nothing and is in a sense the right number: the end bolts are the ones that carry most of the load, and the ones that will slip first if the splice is ever overloaded. A splice whose end bolts are properly clamped will not slip at a load much below its design slip load even if a middle bolt is loose, because the loose bolt’s share is small until the ends have slid.

The end bolts are where slip begins anyway

The last point is worth making precisely, because it is what turns the loop’s blindness from a defect into a near-irrelevance for strength. A friction splice reaches gross slip not when its total load reaches the sum of its bolts’ slip loads but when its end bolts reach theirs and begin to slide, after which the load redistributes inward and the row slides progressively. For this row the end bolts reach 86 kN at a total of 304 kN, under three fifths of the row’s nominal 516; a loose middle bolt makes no difference to that at all — the third bolt at half still lets the row reach 304 — while a loose end bolt, reaching its own 43 kN first, brings it forward to 153. The loop measures the clamps of exactly the bolts whose clamps set the first slip.

What it does not measure is the reserve after first slip, which depends on every bolt — and for a joint whose design rests on friction for its fatigue behaviour, first slip is the event that matters. The middle bolts’ preload matters for the joint’s slip at its full rating and for its stiffness after the end bolts have slid, which the joint that carries nothing until it slips followed through its load–slip curve. A loop is not an inspection of those.

What a splice could be given instead

The finding suggests its own remedies, and they are about where the measurement is taken and which bolts are trusted rather than about the bolts. The first is to accept the census for what it is. A loop taken across a splice is a reliable check of the two end bolts’ clamp — the bolts that set the splice’s first slip — and a row whose end bolts read tight is a row that will not slip early whatever its middle bolts hold. That is a narrower statement than “the splice is tight”, and it is the one the loop can support.

The second is to make the middle bolts matter less, which is what a long friction splice already does without anyone intending it: their share of the load below slip is a tenth or so of an end bolt’s, and their clamps matter only after the end bolts have slid. The third is to check the middle bolts by something that reads them directly. A torque check, or a direct-tension indicator under the nut, reads each bolt’s own clamp, with the scatter the torque that goes into the thread priced; a loop reads none of them except the ends. The two kinds of check are complementary in exactly the way the row’s mechanics divides the bolts: the loop for the ends, the bolt-by-bolt check for the middle.

The row’s simplifications

Every bolt here shares one slip factor and one patch radius, and only the clamp varies. A real row has a scatter of slip factor too, larger than its scatter of preload, which the wrench that reads the rust measured as the faying surfaces age, and the loop cannot tell a low slip factor from a low clamp because it reads only their product. The plates are elastic and equally stiff, so the row is symmetric; a lap splice of unequal plates, or a double-cover splice whose cover plates are thinner than the main plate, loads one end more than the other, and its loop then reads mostly that one end. The bolts are in one line, where a real splice has several lines across its width and a gauge across it averages them. And the contacts follow Mindlin’s solution for a Hertz-like pressure, the assumption the first essay named; a flat pressure would weight the clamps differently in the loop’s higher terms but would not change the leading one, which is all the row’s census depends on.

The plates’ stretch also includes no bolt bending, no hole clearance and no bearing — the bolts never touch the sides of their holes, which is the premise of a friction joint below slip and the thing the hole made bigger so the steel would fit showed is lost at once if the joint ever slides.

Still open: the middle bolts read from the side

The loop sees the end bolts because the gauge spans the splice, and the splice’s load reaches the middle bolts last. A gauge placed between two middle bolts reads the slip between the plates there, which is small, but its small loop is drawn by the bolts on either side of it rather than by the whole row — its census is weighted by the forces near the gauge rather than by the forces at the ends. Whether a set of short gauges along the row, each reading its own local loop, can be inverted into every bolt’s clamp, or whether the middle bolts’ loops are so small that a gauge between them is reading noise at any cycle a splice can be given in service, is the question that looking at the middle of the row puts to the torque that goes into the thread and the clamp it is supposed to deliver.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

The objects this essay names

Each one links to every other essay that touches it.