Connections

The joint that hides its clamp in its loop

A friction joint loaded well below slip looks like a piece of solid steel, and the stiffness it shows a passing lorry has no clamp in it at all: a bolt at half its preload starts out exactly as stiff as one at full. The clamp is not in the stiffness but in the loop. Cycle the joint through a fifth of its slip load and the edge of each clamped patch slips a little, both ways, and the loop it traces is 0.17 µm wide at full preload and 0.40 at half. A proof load can read a joint's clamp, but only by its hysteresis, and only with a gauge good to a tenth of a micrometre.

Assumes The joint that carries nothing until it slips and The force that is whatever it needs to be.

The wrench that reads the rust tried every way of finding the preload in a slip-resistant joint that had been in service for twenty years, and found that each of them read something else: a wrench on the nut reads the friction the thread has acquired, a load-indicating washer the largest force the bolt ever carried, an ultrasonic reading the bolt’s length against a record nobody kept. Every one of them was an attempt to read the tension in a bolt. The essay ended on a different idea. What a slip-resistant joint relies on is not the bolts’ tension but the slip resistance — clamp times friction — and a joint can be loaded in shear and watched. Loading it to slip is out of the question in a standing structure. Loading it to a fraction of slip — a jacked load across a splice, or a lorry of known weight — and reading the response might bound the clamp from below, if the joint’s behaviour below slip depends on its clamp strongly enough to be read.

The obvious version of the idea is to read the joint’s stiffness. That version fails, and the reason it fails points to the version that works.

A clamp that falls to nothing at its edge

The joint that carries nothing until it slips drew a friction joint’s load–slip curve as a stiff straight line up to the slip load and a plateau after it: below slip, the plates are stuck. That is right at the scale of millimetres and wrong at the scale a partial proof load lives at. A bolt clamps the plates over a patch round its hole, and the clamping pressure is not uniform: it is greatest near the bolt, where the head and washer press, and falls away outwards to nothing at the edge of the patch, beyond which the plates are barely in contact. A shear applied to the joint tries to slide the whole patch. Where the pressure is high, friction holds. At the edge, where the pressure is nearly nothing, so is the friction, and the edge cannot hold any shear at all. It slips.

So below slip, a friction joint is not stuck everywhere. It is stuck in a central disc and slipping in an annulus round it, and the annulus grows inwards as the shear rises, until at the slip load it reaches the centre and the whole patch slides. This is partial slip, worked out by Cattaneo in 1938 and Mindlin in 1949 for two bodies pressed together and then pushed sideways. For a circular patch whose pressure has the shape a Hertzian contact gives it — highest at the centre, falling to zero at the edge as the square root of 1−r2/a21 - r^2/a^2 — the slide of one plate over the other under a shear QQ is

δ(Q)=3μN16 aG∗[1−(1−QμN)2/3],1G∗=2(2−ν)G,\delta(Q) = \frac{3\mu N}{16\,aG^*}\left[1 - \left(1 - \frac{Q}{\mu N}\right)^{2/3}\right],\qquad \frac{1}{G^*} = \frac{2(2-\nu)}{G},

with NN the clamp, μ\mu the friction and aa the patch’s radius. The Hertzian shape is an assumption: a bolt’s clamp spreads through the plates in a cone and the true pressure is whatever that cone and the plates’ flatness make it. What follows depends on one feature of it only — that the pressure falls to nothing at the edge — which any real clamp shares.

The bolt here is the earlier essays’: an M20 of grade 10.9 at its full preload of 172 kN, on a blasted faying surface with a friction of 0.5, so one patch slips at 86 kN. The patch is taken as 20 mm in radius, about the reach of the washer’s cone into 15 mm plates.

Stiffness with no clamp in it

A friction joint's slide below slip, at three clamps. The slide across one bolt's clamped patch, in micrometres, against the shear on it, up to slip, with the preload at all of its 172 kN, three quarters and half, friction 0.50. All three start at 3.81 kN per micrometre, the patch stuck everywhere. At 17 kN they have slid 4.621, 4.683 and 4.822 µm; the slip loads are 86, 65 and 43 kN.
Fig. 1 The slide across one bolt’s clamped patch against the shear on it, up to slip, with the preload at all of its 172 kN, three quarters and half, friction 0.5. All three start at 3.81 kN per micrometre. At 17 kN they have slid 4.62, 4.68 and 4.82 µm; they slip at 86, 65 and 43 kN.

Expand the formula for small QQ and the clamp cancels: the slope at the start is 8aG∗8aG^*, which for two steel plates and a 20 mm patch is 3.81 kN per micrometre. It is the stiffness of the patch stuck everywhere, an elastic property of steel and of the patch’s size, and NN and μ\mu appear nowhere in it. A joint at half its preload, or at a quarter, starts out exactly as stiff as one at full.

The three curves in the figure are one curve until well into the load range. At 17 kN — a fifth of the full slip load, a load a heavy lorry could put on one bolt of a splice in a short-span bridge — they have slid 4.62, 4.68 and 4.82 µm, four per cent apart for a halving of the clamp. Only as each approaches its own slip load does it bend away from the others, and by then the test has become the thing the test was meant to avoid.

What the joint's stiffness says about its clamp. Against the share of a 172 kN preload still in the bolt: the patch's stiffness at the start of loading, 3.81 kN/µm at every share; its secant stiffness to 17 kN, 3.27 at 30% and 3.68 at full preload; and the secant a gauge over 100 mm of plate reads, 1.32 and 1.38.
Fig. 2 Against the share of the 172 kN preload still in the bolt: the patch’s stiffness at the start of loading, 3.81 kN/µm at every share; its secant to 17 kN, from 3.27 at 30% to 3.68 at full preload; and the secant a gauge over 100 mm of 70 × 15 mm plate reads, 1.32 and 1.38.

What a gauge across the joint reads makes it worse. A gauge cannot be fixed to the faying surface; it spans the joint, and between its points there is plate, stretching under the same load. Over 100 mm of a 70 by 15 mm strip of plate — the plate one bolt of a row carries — the plate alone gives 7.7 µm at 17 kN, more than the patch’s slide, and it is in series with it. The secant stiffness the gauge reads is 1.379 kN/µm at full preload and 1.357 at half. A joint that has lost half its clamp is 1.6 per cent softer to the instrument. A temperature change of a tenth of a degree during the test moves the gauge’s reading by about as much.

So the answer to the earlier essay’s question, put the way it put it, is no: the stiffness of a friction joint below slip does not depend on the preload strongly enough to be read. It barely depends on it at all, and where it starts it does not depend on it in the slightest.

The loop is where the clamp is

The loop a proof load traces, with the stuck part taken away. One cycle of shear between ±17 kN on the bolt's patch, the slide less what a patch stuck everywhere would give, in micrometres: at the full 172 kN preload the loop is 0.169 µm wide at zero load; at half, 0.401. The slides the two share, 4.46 µm at the peak, are left out.
Fig. 3 One cycle of shear between ±17 kN on the bolt’s patch, the slide less the 4.46 µm the patch stuck everywhere would give at the peak: at the full 172 kN preload the loop is 0.169 µm wide at zero load; at half, 0.401.

The annulus that slips is where the clamp is. On loading it grows inwards, slipping in the direction of the load; on unloading it cannot simply slip back, because friction resists the reversal just as it resisted the load. Mindlin and Deresiewicz worked out what happens: a new annulus starts slipping backwards from the edge, inside which the old forward slip is frozen. The slide on the way down is δ∗−2f((Q∗−Q)/2)\delta^* - 2f\big((Q^* - Q)/2\big) rather than retracing the way up, and a cycle between ±Q∗\pm Q^* traces a closed loop.

The loop is thin. Its width at zero load is the slip annulus’s work, which to first order is the elastic slide times Q∗/6μNQ^*/6\mu N — the stuck patch’s slide, scaled by how near the load is to slip. At ±17 kN with the full clamp the loop is 0.169 µm wide. With half the clamp it is 0.401 µm, not twice but 2.4 times as wide, because the curve’s bend is not quite linear in Q/μNQ/\mu N. Drawn with the stuck patch’s straight line taken away, as in the figure, the two loops are plainly different; drawn as they would come off a gauge, they are hairlines on a 12 µm stroke.

The loop is also energy. A cycle between ±17 kN dissipates 3.8 N·mm at the full clamp and 9.1 at half — the friction damping of a bolted joint, which is real and is the reason bolted structures ring down faster than welded ones. Its area grows as the load cubed over the clamp, so a slackened joint damps more, and it does so where its slip resistance is least.

How wide, at what load

How wide the loop opens, at three clamps. The width at zero load of the loop a cycle of shear between ±Q traces on the bolt's patch, in micrometres, against Q, with the preload at all of its 172 kN, three quarters and half. At ±17 kN, 0.169, 0.238, 0.401 µm; at ±30 kN, 0.60, 0.89, 1.76.
Fig. 4 The width at zero load of the loop a cycle of shear between ±Q traces on one bolt’s patch, against Q, with the preload at all of its 172 kN, three quarters and half. At ±17 kN, 0.169, 0.238 and 0.401 µm; at ±30 kN, 0.60, 0.89 and 1.76.

The loop widens as the square of the proof load. At ±10 kN it is 0.06 µm at full preload; at ±17, 0.17; at ±30, 0.60, by which point a joint at half its preload has a loop of 1.76 µm and is within thirteen kilonewtons of slipping. That is the dilemma of any non-destructive test of strength, set out in micrometres: the signal grows as the test approaches the thing it must not reach.

A passing lorry is a weaker test still, because it loads the joint one way: 0 to 17 kN and back is a cycle of range 17 kN, not 34. Its loop is the loop of a ±8.5 kN cycle, 0.04 µm wide at full preload and 0.08 at half. A jack that pushes both ways is worth four times as much in loop width as the same jack pushing one way, which is a strong reason to make a proof test a jacked reversal rather than a load that happens to pass.

What share of the reading carries the clamp

How much of the gauge's reading carries the clamp. The part of the reading of a gauge over 100 mm of plate across the joint that is not in proportion to the load, as a percentage of the reading, against the shear on one bolt's patch. At 17 kN, 1.31%, 1.80%, 2.89% at full, three-quarter and half preload, of a reading of 12.3 µm.
Fig. 5 The part of the reading of a gauge over 100 mm of plate across the joint that is not in proportion to the load, as a percentage of the reading, against the shear on one bolt’s patch. At 17 kN, 1.31%, 1.80% and 2.89% at full, three-quarter and half preload, of a reading of 12.3 µm.

Read as a proportion of what the gauge sees, the clamp’s signature is a curvature in the load–reading line: 1.3 per cent of a 12.3 µm reading at 17 kN with the full clamp, 2.9 per cent with half. The difference between the two is 0.2 µm. An extensometer that resolves 0.05 µm — a good capacitive or laser gauge, mounted well, on a structure that is not moving with the traffic — can see it; a dial gauge or a strain gauge on the plate cannot. And the curvature is equally produced by anything else that bends the line: a plate yielding locally at the bolt hole, a gauge mount that slips, a load cell that is not quite linear.

That is why the loop is the better reading than the curvature, although they come from the same slip. A loop is a difference between two branches at the same load, measured within one cycle, so the plate’s stretch, the mount’s stiffness and the load cell’s calibration all cancel; only something that dissipates energy between the up and down branches can open it. Friction at the patch’s edge is the main such thing in a bolted splice.

The proof load a gauge needs

The proof load that tells a full clamp from half of one. The cycle of shear, ±kN on one bolt's patch, at which the loop of a joint at half its 172 kN preload is wider than the loop at full preload by the gauge's resolution, against that resolution. For 0.05 µm, ±8.9 kN, 10% of the full slip load; for 0.2 µm, ±16.0, 19%; for 1 µm, ±28.6, 33%.
Fig. 6 The cycle of shear on one bolt’s patch at which the loop of a joint at half its 172 kN preload is wider than the loop at full preload by the gauge’s resolution, against that resolution. For 0.05 µm, ±8.9 kN, 10% of the full slip load; for 0.2 µm, ±16.0, 19%; for 1 µm, ±28.6, 33%.

The practical question is how large a proof load must be to tell a joint at full preload from one at half, with a given gauge. Set the difference in loop width equal to the gauge’s resolution and solve: with a gauge good to 0.05 µm, ±8.9 kN on each bolt, a tenth of the full slip load; with 0.2 µm, ±16 kN, a fifth; with a gauge good only to a micrometre, ±29 kN, a third of the slip load and two thirds of the slip load of the half-clamped joint the test is looking for. A test that must not slip the joint it is testing can afford the first and perhaps the second. The third is a test that can only find a slack joint by coming close to slipping it.

So the answer the earlier essay hoped for exists in principle and is demanding in practice: a jacked reversal of a tenth to a fifth of the slip load, a gauge resolving a twentieth to a fifth of a micrometre across the splice, and a reading of the loop rather than of the slope. That is a laboratory standard of measurement on a structure in the open, and the temperature alone — a 100 mm steel gauge length moves 1.2 µm for every degree — requires each cycle to be completed in seconds.

Two slips in one splice, a thousand times apart

The slip measured here should not be confused with the slip that decides a bearing joint. The splice that forgets how it was bolted followed a girder splice in 2 mm clearance holes whose plates slid across their holes at every reversal of the moment, 13.6 milliradians at a time — millimetres of movement at the plates. That is gross slip, the whole patch sliding, and it happens only once the slip resistance has been exceeded. The partial slip of a sound friction joint is micrometres, at loads a fifth of slip, confined to the edge of each patch, and it never takes the joint anywhere: the stuck disc in the middle holds the plates together and the loop closes. The first is a joint that has failed as a friction joint and is working as a bearing one; the second is a friction joint working exactly as designed, and saying, in the width of its loop, how close it is to the first.

The two also share a cause with a third failure. A patch whose edge slips back and forth by a fraction of a micrometre for millions of cycles is fretting, and fretting starts fatigue cracks at the edge of the stuck zone — in the plate, outside the hole, where a bolted detail’s category assumes the crack will not be. A slack bolt widens the slipping annulus as 1/μN1/\mu N, and with it the region where those cracks begin, so the same loss of clamp that the loop measures is also, quietly, a loss of fatigue life.

What else widens the loop

The loop’s width at a given proof load is the stuck patch’s slide times Q/6μNQ/6\mu N, and the stuck patch’s slide is Q/8aG∗Q/8aG^*, so the width goes as Q2/(aG∗μN)Q^2/(aG^*\mu N). The clamp is in the denominator, which is the point of the test; so is the patch’s radius. A patch 10 per cent smaller — an oversize hole, a thinner washer, a thinner outer plate that spreads the clamp less — opens a loop 10 per cent wider and is indistinguishable, to the loop, from a clamp 10 per cent lower. The hole made bigger so the steel would fit found the hole factor cutting slip resistance for reasons a code expresses as a ratio of characteristic values; here a larger hole shows up as a smaller patch, and a loop measured on oversize holes has to be read against a patch of their size. The friction is in the denominator too, so the loop measures slip resistance, μN\mu N, and not the clamp alone — which is what a joint’s designer cares about, and which no reading of the bolts can give.

Loops read across a joint also add the bolts’ losses in series with whatever else dissipates between the gauge’s points. A prying flange, the subject of the force the bolt never saw applied, opens and closes its own contact under load; a base plate’s holding-down bolts, as the nut turned after the storm found, stretch and settle. A test of a shear splice should be laid out so that its gauge spans the faying surfaces and nothing else.

Which free body the slide belongs to

The free body is one plate’s patch round one bolt, cut along the faying surface. On it act the bolt’s clamp NN, spread as the assumed pressure over a patch of radius aa, and the shear QQ from the plate beyond; along the cut, a shear traction that cannot exceed μ\mu times the local pressure at any point. Equilibrium requires the traction to sum to QQ; compatibility requires the stuck central disc to move as one with the plate. Those two conditions, with the elastic half-space’s response to a tangential traction, give the stuck disc’s radius c=a(1−Q/μN)1/3c = a(1 - Q/\mu N)^{1/3} and the slide formula. A preloaded bolt in a clearance hole carries none of the shear itself until the patch slides, which is why the bolt’s own stiffness appears nowhere.

What the patch leaves out

The surfaces are smooth. Real faying surfaces are blasted or coated and touch only at the peaks of their roughness, and the tangential stiffness of a rough contact rises with the clamp — more weakly than in proportion, as the asperities flatten and more of them touch. That gives a rough joint some of the clamp-dependence in its initial stiffness that a smooth one lacks. It would make the stiffness version of the test a little less hopeless than the figures show; measured contact stiffnesses vary by more between nominally identical surfaces than the effect, which is why it is not a measurement to rely on.

The pressure is Hertzian and the patch fixed. A real clamp’s pressure, set by the cone through the plates, need not have the square-root edge, and a different edge opens a different loop at the same load; the numbers here would have to be calibrated on a joint of the same detail before a measured loop could be read as a clamp. The patch’s radius barely changes with the clamp for a bolted joint, unlike a Hertz contact whose radius grows with load, so taking it fixed is closer to the joint than Mindlin’s original geometry is.

One bolt is a whole joint. In a row of bolts the shear is not shared equally — the bolts that do not share found the end bolts carrying most of it — so the end bolts’ patches slip first, and a proof load opens their loops before the middle ones’. A joint whose end bolts are slack would show it earlier than one whose middle bolts are.

Friction is constant. The coefficient of a blasted surface at micrometre slips is not the coefficient at slip, and fretting under many small cycles changes it over time; a loop measured today says what the clamp times today’s friction is, which is the slip resistance and so the right thing to measure, but not the clamp alone.

Still open: the joint whose bolts are not all alike

Every patch here belongs to a bolt at one preload, and a joint’s loop is then one bolt’s loop times the number of bolts. An old joint will have bolts at different preloads — the wrench that reads the rust found the spread wide — and a loop measured across a whole splice is the sum of loops that grow as each bolt’s load squared over its own clamp. A splice with one slack bolt among twelve has a loop only a little wider than a sound one, while a splice whose slack bolts are at the ends, where the load concentrates, has a loop much wider. Whether a measured loop can be read back into the weakest bolt’s clamp, or only into an average that a single slack bolt can hide behind, needs the row’s load sharing and the patches’ slips solved together.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

What links here

Every essay whose body links to this one.

The objects this essay names

Each one links to every other essay that touches it.

Bolt tensionCoefficient of frictionDampingFrictionHysteresisInspectionPreloadSlip resistance