Connections

The splice that forgets how it was bolted

A girder splice bolted through clearance holes picks up its plates in an order set by how the bolts happened to sit, and under a moment one way a bad fit-up can yield a cover at half the moment a centred one reaches. Reverse the moment and the order is lost: the first excursion pushes every plate across its hole, the fit-up is forgotten, and from then on every splice of 2 mm holes behaves alike. It does not ratchet. It crosses 13.6 milliradians of slack at every reversal, and above about 726 kN·m its covers yield both ways every cycle — 150 below the same splice with fitted bolts.

Assumes The joint that is crooked by construction, The joint that has to be as good as the member and The structure that settles down, and the one that walks.

The splice that waits for its covers took a girder spliced at mid-span with a cover plate above and below each flange and two web plates, all bolted through holes 2 mm larger than the bolts, and loaded it once, to a sagging moment. A snug bolt in a clearance hole carries nothing until its plate has slid far enough for the shank to bear, so the plates arrived in an order set by how far each had to travel: the covers far from the axis first, the web plates last. At 700 kN·m four of the six web rows carried nothing and the bottom cover stood at 341 N/mm² where plane sections said 270. Where the bolts happened to sit in their holes mattered as much as the clearance: a fit-up drawn at random put first yield anywhere from 392 kN·m at the low fractile to 752 for a centred one, and preloaded bolts, which hold their plates by friction and never slip, put it at 936.

That girder was loaded one way. A splice near a point of contraflexure, in a continuous girder whose moment swings with the traffic, or in a frame that the wind pushes from both sides, sees a moment that crosses zero and reverses. The essay ended on the question that reversal raises: whether a splice whose plates have slid to bear one way, and must slide back across the whole clearance to bear the other way, accumulates slack with every reversal — a splice that ratchets — and whether the poorly fitted splice’s early yield is repeated on every cycle.

Driven both ways

The splice is the same. Each plate is a spring of its own area and length, in series with its bolts, which carry nothing while the plate slides across its holes and bear once it has crossed them; the plate yields at 355 N/mm² in tension or compression and keeps whatever plastic stretch it has taken. Each plate remembers its slide and its stretch from one step to the next. The girder is turned at the cut by a rotation, and at each rotation the axial position is found at which the plates carry no net force, so the plates’ forces add up to a moment.

What changes is the driver. Instead of turning the cut one way until a target moment is reached, it turns it until the moment reaches +M+M, then back until it reaches −M-M, and on, for as many cycles as asked. Every plate’s state carries through: a plate that yielded on the way out unloads elastically on the way back, slides back across its hole, bears on the far side, and may yield again in the other sense. A splice that ratchets would show its peak rotations growing from one cycle to the next; one that shakes down would show them repeat.

The loop and the slack in it

The splice's moment against its rotation, through four reversals. The girder splice of 2 mm clearance holes driven four times to ±700 kN·m, its rotation across the cut in milliradians, with snug bolts in a drawn fit-up and with the same bolts preloaded to 171.5 kN. Snug, each reversal crosses 13.3 mrad of slack at almost no moment and the peaks reach ±11.8; preloaded, 0.09 mrad and ±1.6.
Fig. 1 The girder splice of 2 mm clearance holes driven four times to ±700 kN·m, its rotation across the cut in milliradians, with snug bolts in a drawn fit-up and with the same bolts preloaded to 171.5 kN. Snug, each reversal crosses 13.3 mrad of slack at almost no moment and the peaks reach ±11.8; preloaded, 0.09 mrad and ±1.6.

The snug splice’s loop is mostly slack. From a sagging peak the moment falls elastically as the plates unload, and then as it passes through zero the plates let go of their bearing faces and slide back across their holes. For 13 milliradians of rotation the splice carries almost nothing; then the plates arrive on the other side, the hogging moment builds, and the cut turns another 2 or 3 milliradians to its peak. The rotation at the peaks, ±11.8 mrad, is nearly all clearance. The same splice with its bolts preloaded to 171.5 kN, the preload of an M20 bolt of grade 10.9, holds every plate by friction across the whole reversal and turns ±1.6 mrad, the elastic stretch of the plates and nothing else.

This is the joint that carries nothing until it slips made cyclic. A reversal is the worst case for a bearing joint in clearance holes, since a moment that only grows takes its slack once; a moment that reverses takes it every time.

Nothing walks

The rotation at each peak, cycle by cycle. The splice's rotation at each sagging and each hogging peak through six cycles at ±700 and ±900 kN·m, snug bolts in a drawn fit-up. The first sagging peak at 700 is 12.6 mrad and every later one 11.7; at 900, 14.3 and then 12.7 sagging, 16.7 hogging. The slack is crossed each time and grows no larger.
Fig. 2 The splice’s rotation at each sagging and each hogging peak through six cycles at ±700 and ±900 kN·m, snug bolts in a drawn fit-up. The first sagging peak at 700 is 12.6 mrad and every later one 11.7; at 900, 14.3 and then 12.7 sagging, 16.7 hogging. The slack is crossed each time and grows no larger.

The question of a ratchet is answered by the peaks, and the answer is no. At ±700 kN·m the first sagging peak is at 12.6 mrad and every one after it at 11.7: the first excursion was larger, because the drawn fit-up had some plates waiting at the far side of their holes, and the first push seated them, but from the second cycle the splice repeats itself to the last decimal. At ±900 the first peak is 14.3 mrad and the later ones 12.7 sagging and 16.7 hogging — the girder is not symmetric, its top flange heavier than its bottom, so its hogging is softer — and again every later cycle repeats the second.

The structure that settles down, and the one that walks set out the two ways a structure under a repeated load can end: it shakes down, settling into a state that repeats, or it ratchets, walking a little further every cycle until it collapses. A ratchet needs a mechanism whose plastic strain in one direction is not reversed by the next half cycle. A splice driven between equal and opposite moments has no such mechanism: whatever plastic stretch a plate takes one way, the reversed moment asks it to take back. It cannot walk.

What it can do is the third thing, between the two: alternate. A plate may yield one way on the sagging half and the other way on the hogging half, every cycle, and repeat. The peaks then repeat, as here at 900, and the splice does not walk, but its plates are working plastically every cycle — the fourth regime that the map with three regions places in a corner of its map, and that yielding one way and then the other follows to its end in low-cycle fatigue.

Where every cycle begins to yield

Plastic stretch that comes back every cycle, against the amplitude. The largest change of any plate's plastic stretch between the last two peaks of four cycles, against the amplitude: snug bolts in 2 mm holes centred and in drawn fit-ups (the mean of four), fitted bolts, and preloaded. At 800 kN·m, 0.64, 0.51, 0.00 and 0.00 mm; at 1,000, 5.02, 4.89, 1.53 and 0.29.
Fig. 3 The largest change of any plate’s plastic stretch between the last two peaks of four cycles, against the amplitude: snug bolts in 2 mm holes centred and in drawn fit-ups (the mean of four), fitted bolts, and preloaded. At 800 kN·m, 0.64, 0.51, 0.00 and 0.00 mm; at 1,000, 5.02, 4.89, 1.53 and 0.29.

The measure of alternating plasticity is the change in any plate’s plastic stretch between a late sagging peak and the hogging peak after it: nothing if the splice has shaken down, the plastic strain the plate is cycling through if it has not. For the centred splice in 2 mm holes it is nothing up to 700 kN·m and 0.64 mm at 800, which in a 400 mm plate is a plastic strain range of 0.16 per cent each cycle. By 1,000 kN·m it is 5.0 mm, over 1 per cent. Splices with drawn fit-ups do almost exactly the same, 0.51 mm at 800 and 4.9 at 1,000. Fitted bolts, with no clearance, keep the splice elastic to 800 and cycle 1.5 mm at 1,000. Preloaded bolts barely yield at all below 1,000.

The figure also contains the result the title is about. The drawn fit-ups and the centred one lie on top of each other. Under a moment one way the drawn fit-ups were the problem: plates that had to travel least arrived first, carried what the late ones did not, and yielded at moments down to 392 kN·m at the low fractile. Under a reversing moment those early yields happen once, on the first excursion, and seat the plates. On the way back every plate slides across its whole clearance to the far face, whatever its starting position, and the next sagging half finds every plate at the full clearance from its bearing face. The fit-up is forgotten. From the second cycle every 2 mm splice is the same splice, with its bolts sitting at the extreme of their holes in turn, and the drawn fit-ups behave as the centred one does because, in effect, they have become it.

The limit, against the clearance

The moment the splice can reverse without yielding every cycle. The amplitude above which some plate yields both ways in every cycle, against the holes' clearance, with snug bolts centred: 872 kN·m with fitted bolts, 726 at 2 mm and 649 at 4. Preloaded bolts in 2 mm holes, 904. The centred splice's first yield under a moment one way, at 2 mm, is 752.
Fig. 4 The amplitude above which some plate yields both ways in every cycle, against the holes’ clearance, with snug bolts centred: 872 kN·m with fitted bolts, 726 at 2 mm and 649 at 4. Preloaded bolts in 2 mm holes, 904. The centred splice’s first yield under a moment one way, at 2 mm, is 752.

The amplitude at which alternating plasticity begins is a property of the splice and its clearance and not of its fit-up. For the centred splice in 2 mm holes it is 726 kN·m; for the four drawn fit-ups, 721, 737, 743 and 755. With fitted bolts it is 872. With 4 mm of clearance, an oversized hole, 649. Preloaded bolts in 2 mm holes raise it to 904, because the friction keeps the plates from sliding and the splice behaves as fitted, slightly stiffer still since the friction shares load that bearing would not.

The limit for the snug splice in 2 mm holes, 726, sits just below its one-way first yield of 752. That is the arithmetic of shakedown in its simplest form: a structure shakes down under a range of load if the elastic range of every element can absorb the cycle. Under a reversing moment each plate’s elastic range is twice its yield force, from yield in tension to yield in compression, and the plate whose stress would reach yield in each direction is the plate the clearance overloads — the outer bottom cover, which carries more than its share because the web plates arrive late. A splice whose covers carry more than plane sections say has a lower shakedown limit by exactly that excess. The fitted splice’s 872 is the plane-sections answer; the snug splice’s 726 is 17 per cent below it, and that 17 per cent is the clearance.

Forty millimetres at mid-span

The slack crossed at every reversal. The rotation the splice crosses as the moment passes between −5% and +5% of ±700 kN·m, against the clearance, snug and preloaded, and the mid-span movement it makes in a 12 m girder spliced at mid-span. At 2 mm, 13.6 mrad and 41 mm snug, 0.09 mrad preloaded; with fitted bolts, 0.36 mrad.
Fig. 5 The rotation the splice crosses as the moment passes between −5% and +5% of ±700 kN·m, against the clearance, snug and preloaded, and the mid-span movement it makes in a 12 m girder spliced at mid-span. At 2 mm, 13.6 mrad and 41 mm snug, 0.09 mrad preloaded; with fitted bolts, 0.36 mrad.

The slack the splice crosses at each reversal grows in proportion to the clearance, about 6.5 milliradians per millimetre, and in a 12 m girder spliced at mid-span 13.6 mrad is a movement of 41 mm at the splice with no change of load to speak of. A girder carrying traffic that reversed its moment at the splice would drop 41 mm and rise again with every vehicle that moved the moment’s sign. Preloaded, the same reversal crosses 0.09 mrad, a quarter of a millimetre.

That is the practical form of the result, and it is the reason connections in which the load reverses are made slip-resistant. That practice is not, as it is sometimes read, a response to clearance-hole joints are weaker under reversal than under a one-way load; their shakedown limit is close to their one-way first yield. It is a response to their rattling: each reversal is a slip across the clearance, an impact as the plates arrive, and a girder that moves by its own slack at the speed of the load that reverses it.

The range the covers work through

The outer bottom cover's stress range in each cycle. The stress range of the outer bottom cover plate between a sagging and a hogging peak, against the amplitude, snug bolts in 2 mm holes and preloaded. At 500 kN·m, 518 and 400 N/mm²; at 700, 687 and 565, 22% more. Twice the yield stress, 710, is where the range stops growing and the plate yields both ways.
Fig. 6 The stress range of the outer bottom cover plate between a sagging and a hogging peak, against the amplitude, snug bolts in 2 mm holes and preloaded. At 500 kN·m, 518 and 400 N/mm²; at 700, 687 and 565, 22% more. Twice the yield stress, 710, is where the range stops growing and the plate yields both ways.

The cover’s stress range under a reversing moment is the quantity a fatigue check reads, and here clearance costs directly. At 500 kN·m the outer bottom cover works through 518 N/mm² from its sagging to its hogging peak in the snug splice and 400 in the preloaded one; at 700, 687 against 565. The snug cover’s range is 22 to 30 per cent larger at every amplitude, because the cover carries the share the late web plates leave it, in both directions. Above 730 kN·m the range stops growing: it has reached twice the yield stress, 710 N/mm², and every cycle beyond that yields the cover both ways.

The load that never came near failing anything is the reminder that a fatigue crack grows under stress ranges far below these, and that for a bolted splice the detail category is set by the hole, not by the plate. A 22 per cent higher range is, on a slope of three, 1.8 times the damage per cycle. The bolts’ preload buys that back as well as the slack.

What the first reversal does to a bad fit-up

The forgetting has a practical reading that is worth setting out, because it runs against an instinct. A splice assembled with its bolts wherever the drift pins left them is, under a one-way moment, a splice of uncertain strength: the splice that waits for its covers put its first yield anywhere between 392 and 752 kN·m, and a design that wanted to be sure of the higher number had to preload the bolts or ream the holes. That uncertainty is real for a girder that will only ever sag. For a splice whose moment reverses it lasts exactly one excursion.

The first sagging moment that is large enough to bring every plate into bearing seats them all at the sagging faces of their holes, and the first hogging moment seats them all at the hogging faces. After that the splice’s state depends on the clearance alone. A badly fitted splice that survives its first reversal without yielding beyond its covers’ capacity is from then on indistinguishable from a well-fitted one — which, in the numbers here, it does: a drawn fit-up that yields on its first excursion at 700 kN·m takes 0.8 mm of plastic stretch then, 1.4 by the end of the first hogging half, and nothing after. The first reversal is a proof load that the structure applies to itself.

This is the same seating that the hole made bigger so the steel would fit described for erection, run backwards: clearance is provided so that parts drilled apart can be assembled, and the price of it under load is that the parts must slide before they work. A moment that slides them one way and then the other leaves them nowhere in particular to start from, and the fit-up’s memory, which was the whole of the one-way problem, is erased by the cycle.

The two limits the figures give therefore have different uses. The one-way first yield of a drawn fit-up is a statistical quantity and belongs to a girder that only sags. The reversal limit of 726 kN·m is a deterministic one and belongs to every splice of 2 mm holes, however its bolts were set. And the gap between that limit and the fitted splice’s 872 is the cost of the clearance alone, a 17 per cent that preloading or fitted bolts recover and nothing in the erection can.

The splice’s other simplifications

The plates are springs with a single length, each yielding at once across its section, with perfectly plastic behaviour and no hardening; real cover plates harden under cyclic plasticity and their shakedown limit rises a little with each cycle, which makes the limits here conservative. The bolts are springs once they bear, and the holes do not ovalise. Under cyclic bearing a bolt hole elongates, and an elongated hole is a larger clearance; the bolts that arrive one at a time is the essay where that wear was raised and where it remains unmodelled. A splice that alternates its plasticity at the covers is also wearing its holes, and its clearance, and so its limit, would drift down with cycles.

The friction in the preloaded splice is a fixed slip resistance, without the loss of preload under cyclic slip that occurs in practice once friction is exceeded. Above the slip moment a preloaded splice behaves as a bearing splice, and its loop opens. Below it, the 0.09 mrad is the plates’ own stretch.

The moment is equal and opposite at every cycle. A girder at a point of contraflexure sees a moment that swings unequally either side of a dead-load mean, and the splice’s state at the mean is where the slack is crossed. That changes the amplitude at which the covers yield both ways and leaves the conclusion about ratcheting alone: a moment that does not reverse never crosses the slack, and one that does, crosses all of it.

A slack, not a ratchet

A clearance-hole splice under a reversing moment has slack, and the slack is crossed whole at every reversal. It does not accumulate, because each reversal crosses it in the other direction, and it does not care how the bolts were fitted, because the first reversal puts every plate at the far side of its hole. The splice shakes down below an amplitude set by how much the clearance overloads its outer covers — 726 kN·m for 2 mm holes, 17 per cent below the fitted splice’s 872 — and above it its covers yield both ways each cycle and will fail in low-cycle fatigue. The one-way splice’s worst enemy, a bad fit-up, does not survive the first reversal. The reversing splice’s worst enemy is the clearance itself, and preloaded bolts, which remove it, remove the slack, raise the limit to 904 and take a fifth off the covers’ stress range.

Still open: the splice whose moment does not quite reverse

Between a moment that only sags and one that swings equally both ways lies the common case: a dead-load moment with a live-load swing that takes it past zero briefly. Such a splice crosses its slack only when the live load is heavy enough to reverse the moment, and between those crossings it carries its load one way with plates already seated. Whether the plates’ state after a rare reversal is the state the one-way loading left, or a new one with the web plates arriving earlier, and whether a splice that reverses only occasionally ends up fitted better or worse than one that never does, needs the history driven by a mean and a fluctuation rather than by equal and opposite peaks.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

What links here

Every essay whose body links to this one.

The objects this essay names

Each one links to every other essay that touches it.

Clearance holeFabrication toleranceLow-cycle fatiguePreloadRatchetingShakedownSpliceStress range