Concept

Fabrication tolerance — where it appears

The permitted departure of a manufactured part from its drawn dimensions, such as a member's length or a hole's position. In a truss each millimetre of length error reaches a joint multiplied by that member's unit-load force, so small tolerances decide a camber.

Named by 7 essays across 2 fields — each of them below, with the objects they name alongside it.

A weld is a force, and it is applied where the weld is. The bow a welded girder leaves the shop with, against how far its welds sit from the section's centroid. A weld cannot contract while the plate holds it, so it yields in tension and what is left when everything is cold is a locked-in force at about the yield stress: 312 kN for the 1.2 kJ/mm of heat drawn, over a shrinkage zone of 439 mm². Applied 210 mm off the centroid that is a moment, and a moment applied along a member is a curvature: the 12 m girder comes out bowed 12.5 mm, which is L/962 against a fabrication tolerance of L/1000. It also comes out 1.2 mm shorter. Welding symmetrically about the centroid puts the resultant on the neutral axis and the bow becomes 0.00 mm — the same heat, the same force, and no moment at all.

The shape that came out of the shop

A weld cools by seven hundred degrees while the plate holds it, so it yields in tension and stays that way. What is left is a locked-in force of three hundred kilonewtons applied where the weld is, and if that is not on the centroid the member leaves the shop bent.

connections · Weld distortion
What a millimetre on each member does at mid-span. A Pratt truss of eight panels, 24.0 m long and 2.4 m deep, carrying 60 kN of dead load at each top node, drawn with its depth exaggerated. Each member is drawn as thick as, and labelled with, the distance mid-span moves for a millimetre's change in that member's length: its force under a unit load at mid-span. The middle top-chord members move it 2.50 mm per mm — the span over four depths — and the chord members fall off towards the supports: 1.25, 1.88, 2.50, 2.50, 1.88, 1.25 along the top chord. The diagonals move it 0.80 per mm and most verticals 0.50; three verticals — the one at mid-span and the two beside the supports — carry nothing under a load at mid-span and move it not at all (dashed). A truss's shape is its members' lengths, weighted like this.

The camber that lives in the member lengths

A beam is cambered by bending it; a truss cannot be, because it has no curvature to bend — its shape is nothing but the lengths of its members. So a truss's camber is a cutting list, and each millimetre on that list arrives at mid-span multiplied by the member's force under a unit load there: two and a half for the middle chords of a truss ten times as long as it is deep, nothing at all for some verticals. Build only the chords to their dead-load strain and a quarter of the sag stays, the webs' share. Cut every member to a millimetre of scatter and the mid-span misses by six, an eighth of the camber.

deflection · Camber
Fit the counters last, and the tolerance locks in nothing. The largest force random length errors lock into an eight-panel Pratt truss with a counter-diagonal in each of its six interior panels, 24.0 m long and 3.0 m deep, carrying 60 kN of dead load at each interior bottom joint, against the errors' standard deviation: the median draw (solid) and the 95th percentile (dashed) with every member fitted in the shop, and the same with the counters left loose until the truss carries its dead load and then cut to the gap (on the axis). With everything fitted, 174 and 288 kN at 1 mm, 348 and 577 at 2 — straight lines, because the force is proportional to the misfit. With the counters fitted last, nothing at any tolerance: the Pratt truss without its counters is determinate, and a determinate truss takes any length error by moving.

The counter fitted after the load

A truss with a counter-diagonal in every panel cannot take a change of length for free, so a camber cut into its members might seem to lock force into it. One cutting list locks in nothing — every member shortened by its own dead-load stretch — and the simpler lists lock in little. What locks in force is the shop: a millimetre of error per member puts 174 kN into some member of a truss whose largest dead-load force is 471. Leave the counters loose until the dead load is on and cut them to the gap, and the same errors lock in nothing at all.

deflection · Camber
The middle reaction is a dimension, read off in millimetres. The middle reaction under dead load of a Pratt truss continuous over two 24.0 m spans, 3.0 m deep, carrying 60 kN of dead load at each interior bottom joint, against the height of its middle bearing above the level drawn, cut to the continuous list (solid) and as two simple spans (dashed). At the drawn level the continuous list lands with 572 kN, the analysis's value, and the simple-span list with 480 kN, the two spans' own share. Every millimetre the bearing stands high adds 2.6 kN: 10 mm high, 598 kN; 10 mm low, 545; the simple-span list's 92 kN shortfall is the bearing 35 mm low.

The pier's share is cut into the members

A truss continuous over a middle support has one reaction that statics cannot find, and the lengths its members are cut to decide it. Cambered to land level under its dead load on three bearings, a two-span truss puts 572 kN on its pier; cambered span by span, as two simple trusses, the same members on the same bearings put 480 kN there and carry the dead load with no moment over the pier at all. The list chooses the moment diagram. And a millimetre of shop tolerance on every member moves the pier's share as much as a bearing set fourteen millimetres out of level, so a reaction the design depends on has to be set by a jack rather than by a drawing.

deflection · Camber
Where a spliced girder turns, held by friction and in clearance holes. The moment across a girder splice against the rotation of its two halves at the gap. Preloaded bolts hold the plates by friction and the splice turns 1.6 mrad at 700 kN·m; snug bolts centred in 2 mm of clearance turn 11.7 mrad by the time the plates have taken it, and one drawn fit-up 12.5. All three reach the plates' plastic moment of 1,164 kN·m.

The splice that waits for its covers

Put a girder splice's bolts in ordinary clearance holes and every plate has two millimetres to cross before it carries anything. The plates do not cross it together. The ones furthest from the axis arrive first, so at the design moment the web plates are nearly idle, the bottom cover is a third over its stress, and the plate that yields first is chosen by where the erector's drift pin happened to leave the bolts.

connections · Single lap
The splice's moment against its rotation, through four reversals. The girder splice of 2 mm clearance holes driven four times to ±700 kN·m, its rotation across the cut in milliradians, with snug bolts in a drawn fit-up and with the same bolts preloaded to 171.5 kN. Snug, each reversal crosses 13.3 mrad of slack at almost no moment and the peaks reach ±11.8; preloaded, 0.09 mrad and ±1.6.

The splice that forgets how it was bolted

A girder splice bolted through clearance holes picks up its plates in an order set by how the bolts happened to sit, and under a moment one way a bad fit-up can yield a cover at half the moment a centred one reaches. Reverse the moment and the order is lost: the first excursion pushes every plate across its hole, the fit-up is forgotten, and from then on every splice of 2 mm holes behaves alike. It does not ratchet. It crosses 13.6 milliradians of slack at every reversal, and above about 726 kN·m its covers yield both ways every cycle — 150 below the same splice with fitted bolts.

connections · Single lap
Rounds of the jacks: one pier at a time, or all together. The largest pier error as a share of the landed one, the mean of 40 fabrications, against rounds of the jacks — a round being every jack operated once: one pier at a time from the left, 0.49, 0.20, 0.15 after one, two and three rounds; all together from one set of readings, using the truss's own lift matrix, 0.00 after one; using the matrix of a truss whose web does not stretch, 0.30, 0.11, 0.04.

The second pier undoes the first

A truss continuous over one pier has its reaction set by one jack: lift until the load cell reads the design value, pack the bearing, done. Over three piers the jacks argue. Lifting one pier a millimetre hands 85 per cent of what it gains to the pier beside it, so jacking each pier to its own design reaction in turn leaves half the error after a full round and still a seventh after three. The error that will not go is the one the piers share, which lifting them all together barely moves. Read every pier once and solve for all the lifts together, and one round of the jacks does what ten rounds one at a time cannot.

deflection · Camber

Named alongside it

The objects these essays reach for when they reach for this one.

CamberLack of fitClearance holeIndeterminacyPreloadRedundantSpliceSupport settlementThermal gradientTrussCompatibilityCounter-diagonal

All concepts