Stress range — where it appears
Named by 14 essays across 4 fields — each of them below, with the objects they name alongside it.
The load that never came near failing anything
A detail survives sixty-eight million cycles at a stress range that another detail in the same steel survives two hundred and seventy thousand of. The two lie a factor of two hundred and fifty apart, and the material is not on the plot anywhere.
The detail decides and the steel does not
A fatigue check contains no material strength anywhere. The same detail in a steel twice as strong lies on exactly the same line, because a fatigue life is decided by the geometry of a weld and by the stress range it sees — and two per cent of the traffic does most of the damage, because life goes as the inverse cube of the range.
Designed to be found in time
A fatigue design that promises a detail will not crack is making a claim about a hundred years of traffic. A damage-tolerant one assumes it will crack, and sets the inspection interval from how long a crack takes to grow from the smallest size anybody can find to the largest the section can survive.
The cycles that do not count
A fatigue spectrum has to be reduced to one number, and the reduction is a cube-weighted average rather than an ordinary one. Two per cent of the traffic does most of the damage, ninety per cent of it does none at all, and the equivalent range that comes out is nearer the heaviest vehicle than the average one.
The notch a crack does not feel in full
The elastic concentration factor is a property of shape and knows nothing about size, which is what makes it so useful and so misleading. A fatigue crack starts against an average over a volume the material owns, so two notches with the same factor and different radii have different fatigue strengths — and the stronger the steel, the less of that relief it gets.
Which reversal closes the loop
A strain-gauge record is a wiggle, not a list of cycles, and its damage depends on how its reversals are paired. Rainflow pairs each one with the reversal that closes its hysteresis loop. Counting the ranges between neighbours breaks every lorry's cycle into pieces, and on one bridge record it gives a detail 424 years where rainflow gives it 34.
The bolt that was already stretched
Prying is a lever that needs the flange to lift before it can act, and a preloaded bolt does not let it. The bolt carries a fifth of every kilonewton applied until the plates part, and everything after that is the ordinary calculation — which is why preload changes the fatigue answer by a factor of a thousand and the strength answer by nothing at all.
The breeze that uses up a chimney
A chimney that locks in to vortex shedding at a breeze is usually told to accept the motion and check its fatigue. Counting the cycles a real wind climate delivers turns that into arithmetic, and the arithmetic has two surprises. The chimney that collects the most cycles is not the one tuned to the commonest wind but to one a fifth stronger than the climate's scale, so stiffening a chimney can shorten its life. And damping does not lengthen the life in proportion: it ends the count, all at once, at the damping that puts the largest stress range under the detail's cut-off.
Strongest across, and first to crack across
A fillet weld pulled across its length is √1.5 stronger than one pulled along it, and every static check of a weld group uses that. In fatigue the same two directions are rated the other way round: the part of the force across the weld is checked against a detail category of 36 and the part along it against 80. The point of a group that governs the static check need not govern the fatigue one, and checking fatigue there can allow more than twice the load range the weld will take.
The hangers that carry the shear twice
Crossing a tied arch's hangers turns them into the web of a truss, which is why the tie stops bending. It also means a live load's shear passes through them, so as a load runs on from either end each crossed hanger swings from nearly nothing to nearly its most: on a 100 m arch the worst swings through 678 kN, 90% of the largest force in any hanger, where a vertical hanger swings through 194, half of its own. More dead load raises the force and leaves the range alone. The arrangement that is best for strength is the one that hands its hangers to fatigue.
The corner that counts its crossings
As a load crosses a Vierendeel girder, the moment at a post's corner changes sign when the load passes that post. A static check reads the peak, and the peak says the posts beside the supports work twice as hard as the middle one. Fatigue reads the range, and the range says every interior post works the same. A haunch at the corner lowers the corner's range and moves the worst of it to the haunch's toe — so a deeper haunch soon buys nothing, a longer one keeps paying, and a toe two detail categories worse than the corner cancels the haunch outright.
The hanger that cannot be made soft enough
A network arch's crossed hangers swing through nearly all their force as traffic passes, because they are the web of a truss. Make them softer — a spring at each anchorage — and the tie ought to take back some of the shear and the hangers' ranges ought to fall. They hardly do. A tenth of the stiffness takes 6 per cent off the worst range and adds a third to the tie's bending; a fiftieth takes 18 per cent off and multiplies the tie's bending by 3.7. The range belongs to the truss and leaves only when the truss does, which vertical hangers show at 194 kN against 678 and eleven times the bending. So the hanger is sized for its range, eight times the area its strength needs, and the stiffness that comes with it costs the range nothing.
More hangers, and the same steel
A network arch's crossed hangers are the web of a truss, and a live load's shear passes through them, so every hanger swings through nearly all of its force. The obvious cure is more hangers, each crossing more of its neighbours, so that every section's shear is shared among more diagonals. It works hanger by hanger — three times the hangers, a third of the range — and not at all in total: the hangers' fatigue steel, sized for their ranges, is set by the shear the arch carries and barely changes with how many hangers it is divided among. What more hangers buy is elsewhere.
The post sized by what it must survive
A Vierendeel girder's posts are usually all one section, and a crossing load gives them peaks that differ by a factor of two and ranges that barely differ at all. Size each post to its peak and the steel falls by a quarter — and the middle post, lightened to two-fifths of the chords, sweeps twice the stress range the whole girder used to, and lasts a seventh as long. Size each post to its range instead and the girder needs less steel than the uniform one, not more, because the posts that can be lightened are the ones at the ends.
Named alongside it
The objects these essays reach for when they reach for this one.
FatigueDetail categoryCut-off limitMiners ruleStress concentrationCrack growthEndurance limitFree bodyHangerInfluence lineInspectionLoad sharing