Tall building — where it appears
Named by 4 essays across 2 fields — each of them below, with the objects they name alongside it.
The columns are shorter than the core
Every column in a tall building gets shorter as the building is built on top of it, and the core beside it gets shorter by a different amount. The floors between them tilt by the difference — and the difference is largest exactly half way up, because a floor near the top has almost nothing built above it and a floor near the bottom has almost nothing beneath it.
The arm that makes the columns work
The perimeter columns of a tall building are already there, already carrying gravity, and already the furthest thing from the centre. They take almost none of the overturning, because a floor slab transmits shear and not moment — and one storey-deep arm at the right height changes that by nearly a half.
The corner columns take more than their share
A framed tube is a hollow cantilever, and a hollow cantilever's flange ought to be uniformly stressed. It is not, and the reason is that the only route the axial force has into a column in the middle of a face is the in-plane shear of the frame — one bay at a time, from the corner inwards.
What the second arm is worth
One outrigger at its best height removes five sixths of a tall core's drift, which sounds like the end of the argument. A second removes half of what is left, a third half of that, and each of them costs a storey of the most valuable floor area in the building — so the question is not where to put an outrigger but how many the arithmetic still justifies.
Named alongside it
The objects these essays reach for when they reach for this one.
CoreDriftLateral systemCompatibilityDifferential shorteningOptimisationOutriggerServiceabilityStiffnessAxial shorteningBelt trussBending moment