Concept

Core — where it appears

The stack of walls around a building's lifts and stairs, which is usually the whole of its resistance to wind. It behaves as a vertical cantilever, so its drift profile is largest at the top while the frame around it is largest at the bottom.

Named by 9 essays across 4 fields — each of them below, with the objects they name alongside it.

Two differences up the same building, peaking in different places. Differential shortening between a perimeter column and the core of a 40-storey building, plotted up the height. The part driven by load peaks at level 20 — exactly half way up, because a floor near the top has almost nothing built above it to shorten what is beneath, and a floor near the bottom has almost nothing beneath it to shorten. The part driven by shrinkage does not care what is above it at all and accumulates all the way to the roof. Their sum is worst at level 40, at 43 mm, which across a 9 m bay is a floor out of level by one in 208.

The columns are shorter than the core

Every column in a tall building gets shorter as the building is built on top of it, and the core beside it gets shorter by a different amount. The floors between them tilt by the difference — and the difference is largest exactly half way up, because a floor near the top has almost nothing built above it and a floor near the bottom has almost nothing beneath it.

deflection · Differential shortening
A couple applied to the core, and two columns to make it. A 20-storey core with one outrigger at 59% of its height. The arm is stiff in bending and the perimeter columns are stiff in tension and compression, so between them they resist the core's rotation at that level — a couple of 35283 kNm here, carried as a 294 kN pair in the columns at 120 m centres. The compatibility is one equation: the core's rotation at that level, less what the couple takes back out of it, equals the rotation the arm and its columns allow. The top drift falls from 360 mm to 74, which is 80% of it, and the base moment from 73500 to 38217 kNm. The deflected shape is drawn hugely exaggerated: the real top drift is about one five-hundredth of the height.

The arm that makes the columns work

The perimeter columns of a tall building are already there, already carrying gravity, and already the furthest thing from the centre. They take almost none of the overturning, because a floor slab transmits shear and not moment — and one storey-deep arm at the right height changes that by nearly a half.

structures · Outrigger
Two faces, a couple, and a core that does none of it. A sandwich section 61.4 mm deep: two 0.7 mm faces separated by 60 mm of core. The bending is carried as a couple between the faces — 41 N/mm² of tension in one and compression in the other, over a lever arm of 60.7 mm — and the core carries a shear stress of 0.047 N/mm² and nothing else. The parallel-axis term is 98.8% of the section's second moment; the faces' own bending about their own centroids is 0.004% of it, and the core's is 1.2%. Separated by nothing at all the same two faces would be 2.3e+4 times less stiff.

Two skins and the space between them

A sandwich panel is a section made of a material that carries the bending and a material that carries none of it. The parallel-axis term is not a correction here — it is 98.8 per cent of the second moment — and the shear deflection is not a correction either.

sections · Sandwich section
The shear deflection is not a correction. The share of a sandwich panel's deflection that is shear rather than bending, against how slender the panel is. A solid beam at a span-to-depth ratio of 20 spends about a per cent of its deflection on shear; this panel spends 25% at the same ratio, because its core is 2800 times softer in shear than its faces are in tension. At the 37 of the panel drawn it is 9%. The curve falls as the square of the span because bending grows as the fourth power and shear as the second, so the term that is negligible for a long panel is the whole answer for a short one.

The stiffness that belongs to the span

A section's flexural rigidity is a property of the section, and a member's is not. Once shear deformation is counted the effective stiffness contains the span, so the same panel is a different member at three metres and at six — and for a sandwich the correction is not a correction.

deflection · Shear deflection
What the second, third and fourth arms are worth. Top drift removed against the number of outriggers, each arrangement at its own optimum levels, on a 40-storey core 200 m tall. One arm at 59 per cent of the height removes 82.3 per cent of the drift. A second, with both moved to 35 and 71, takes it to 91.6 — a gain of 9.3 points, which is half of what was left. The third is worth 3.0 and the fourth 1.5, and each one costs a storey of the building's most valuable height.

What the second arm is worth

One outrigger at its best height removes five sixths of a tall core's drift, which sounds like the end of the argument. A second removes half of what is left, a third half of that, and each of them costs a storey of the most valuable floor area in the building — so the question is not where to put an outrigger but how many the arithmetic still justifies.

structures · Outrigger
How far a local load spreads, and what is nearest its limit. Along a steel-faced polyurethane cladding panel, 0.5 mm faces of 320 N/mm² steel on an 80 mm core crushing at 0.12 N/mm², from the middle of a strip load of 3.0 N per mm of width spread over 10 mm: the face's deflection over its value under the load, the core's compressive stress over its crushing strength, and the face's bending stress over its yield stress. The load spreads over a length set by the fourth root of the face's bending stiffness over the core's, 1/β = 20.5 mm; the deflection is 1.44 mm under the load and changes sign beyond 48 mm. The core is at 0.60 of its crushing strength and the face at 0.89 of its yield stress: this panel's face yields at 3.36 N/mm and its core crushes at 5.00.

The face that dents and the core that crushes

A sandwich panel carries bending as a couple between its faces, and that is a calculation about the whole panel. Put a local load on one face — a foot, a fixing, a dropped tool — and the face becomes a thin beam on a soft bed, spreading the load over a length the fourth root of their stiffnesses sets. Then either the face yields and dents, or the core crushes beneath it, and which comes first is decided by one thickness: below it the face gives, above it the core does, and a steel-faced roof panel is on the wrong side of it for anyone who walks on it.

sections · Sandwich section
The arm goes in almost the same place whatever shape the wind is. The share of the tip drift removed by one outrigger on a 200 m core of bending stiffness 1.2 × 10¹⁰ kN·m² carrying 6,000 kN of wind in all, with an outrigger of 1.0 × 10⁸ kN·m per radian, against the outrigger's level as a share of the height, for the three profiles of the same total wind. uniform: best at 0.745 of the height, removing 45.6 per cent; power law: best at 0.749 of the height, removing 45.9 per cent; triangle: best at 0.757 of the height, removing 46.4 per cent. The curves lie almost on one another: the triangle, with three quarters of its load in the upper half against the uniform wind's half, moves the best level up by 1.2 per cent of the height.

The arm that ignores the shape of the wind

The outrigger arithmetic is usually done for a wind that is the same at every height, and real wind is not: it grows with height, and an earthquake's first mode loads a building as a triangle. The natural guess is that a load concentrated towards the top moves the best place for the arm. It barely does. Put the same total wind on a 200 m core as a uniform load, a power-law wind and a triangle, and the best level moves by just over one per cent of the height. What moves is the force in the arm — half as much again under the triangle — and how far the top goes, while the arm's own stiffness shifts its best level thirty times as far as the wind's shape does.

structures · Outrigger
The columns and the core shorten apart for decades. For a 200 m concrete building built a storey every week, its perimeter columns at 12 N/mm² and its core at 6 at the base, with an outrigger at 149 m of 1.0 × 10⁸ kN·m a radian: how much the columns (solid) and the core (dashed) have shortened below the outrigger's level, and the difference between them (heavy), in mm, against the years since the first storey was cast, on a log scale. When the building tops out, in week 55, the difference is 7.0 mm; after fifty years it is 30.5. 77% of the difference arrives after the frame is finished — creep under the finishes and the floors above, and the thick columns' slower drying, most of which comes after the core's thinner walls have done theirs.

The arm connected late

An outrigger is often left unconnected until a concrete building is finished, so that the columns and the core can shorten by their different amounts without it. Most of their difference has not happened yet. Three-quarters of fifty years' differential shortening arrives after the frame tops out, and an arm connected then ends up carrying 3.5 MN of it — 60 per cent of what the design wind puts into the same arm, permanently, and in the same direction on both sides of the core. The connection date is the largest load the arm has, and a stiffer arm collects it faster than it collects the wind.

structures · Outrigger
A hat makes the top storeys look stiff. Each storey's own sway factor α up the height of a 20-storey building of a core to the roof and a racking frame (αH 1.0), its gravity scaled to an elastic critical factor of 5.0, under an equal lateral load at every floor: with no hat, with a hat truss at the roof holding the core's rotation with 10 times the core's EI/H, and with the same restraint at storey 10; the building's critical factor 5.0 as a vertical line. With no hat the top storeys read the least, 4.06 at the roof. With the hat the roof storey reads 15.47 and the least, 4.14, has moved down to storey 9. With the outrigger at mid-height the least is back at the top, 3.85.

The hat that hides the lean

A hat truss on a core-and-frame building holds the top of the core, nearly doubles the building's critical load, and makes its top storeys look three or four times as stiff as they did. The storey check believes them. Under the hat the roof storey reads a sway factor of 15 and estimates 7 per cent of second-order drift; the building still buckles leaning, and the roof storey's true increase is 24 per cent. The hat turns the storey check from pessimistic to unsafe at exactly the storeys it was built to stiffen.

stability · Sway stability

Named alongside it

The objects these essays reach for when they reach for this one.

OutriggerTall buildingServiceabilityCompatibilityDifferential shorteningDriftLateral systemOptimisationStiffnessWrinklingConstruction sequenceCreep

All concepts