Concept

Radius of gyration — where it appears

The square root of a section's second moment over its area, a length that is the only section property a column's slenderness contains. It is the one number a section takes into a column calculation, and doubling it quarters the slenderness — which is why hollow sections make better columns than solid ones of the same area.

Named by 9 essays across 3 fields — each of them below, with the objects they name alongside it.

The column curve. Failure load against slenderness, as a fraction of the squash load. A stocky column crushes; a slender one buckles at the Euler load; the crossover is where the two curves meet, and real columns fall below both near it.

Strong enough and still falls over

A column can fail at a fraction of the load its material could carry, by going sideways. Buckling is a failure of stability rather than of strength, and it is decided by geometry.

stability · Buckling
The one length a section carries into a column. Four profiles of equal area, with the radius of gyration r = √(I/A) drawn as the distance it is — a pair of lines either side of the centroid, at the depth the whole area would have to sit at to give the section the second moment it has. As a 4 m pin-ended column the same 3000 mm² of material carries between 7 and 3146 kN, in the ratio of the squares of those radii and of nothing else.

The one length a section takes into a column

A section has an area, a second moment, two section moduli, a shear centre and a torsion constant. A column has heard of exactly one of them, and it is none of those — it is the length √(I/A), which is where the whole area would have to sit to give the section the stiffness it has.

sections · Radius of gyration
A built-up column has a second way to bend. A 12 m column of two chords 300 mm apart, joined by double lacing. On the left it buckles the way a solid column does, by bending; on the right the chords stay straight and the lattice racks, which a solid column cannot do at all. Neither happens alone, and the two flexibilities add rather than the two stiffnesses — so the critical load is 1287 kN against an Euler load of 1341 kN, which is 96% of it, and the column behaves as though its slenderness were 80 rather than 79.

The column made of two columns

A solid column buckles when its bending stiffness runs out. A laced one has a second way to go — the lattice shears, the chords stay straight — and the two flexibilities add rather than the two stiffnesses. A battened column reaches 23% of its own Euler load and behaves as though its slenderness were twice what it is.

stability · Built-up column
A column that has nothing on it but itself. A 30 m column carrying no load except its own weight, with its buckled shape and the axial force that produced it. The force is zero at the top and largest at the base, which is why the answer is not Euler's: the eigenvalue is a load intensity and comes out as q_cr L³/EI = 7.835, a number with no π in it, computed here as the smallest eigenvalue of the same stiffness and geometric-stiffness matrices that give a tip-loaded column its Euler load. It is equivalent to a tip load of 3.18 times as much total weight — a column carries its own weight better than it carries somebody else's, because most of the weight is near the base where the buckle is not. The height limit that follows is a cube root, so a section of radius of gyration 80 mm falls over on its own at 52 m and one of twice that reaches only 82.

Too tall for nothing but itself

Every critical load on this site so far has been applied at the top of a column. A mast carries a load that is zero at the top and largest at the base, the governing equation stops being harmonic, and the answer comes out as a number with no π in it — along with a maximum height that is almost the same for steel, aluminium and wood.

stability · Self-weight buckling
The split is where buckling puts it. A branching column carrying 400 kN to two points 3.0 m apart, over 9.0 m. Every member is drawn at the thickness it needs: the area is the larger of N/σ and what Euler asks of a strut of that length, and 3 of 3 members here are sized by buckling rather than by strength. The split sits at 57% of the height, which is where the total volume is least — 51% less than the fan of straight struts that carries the same load with the same stresses.

The tree that strength does not ask for

A branching column carries a roof on many points and reaches the ground on one. Size every member by its stress and the optimum tree turns out to have no trunk at all — the best answer is a fan of straight struts from the base. Put buckling in and the trunk appears, at 57 per cent of the height.

structures · Branching structure
A Pratt truss of 8 panels. A Pratt truss under equal panel-point loads. The joint equilibrium equations were assembled and solved; 14 members came out in tension, 13 in compression and 2 carrying nothing.

The tie that spends an afternoon as a strut

A tension member is chosen by its area and nothing else. A compression member is chosen by how that area is arranged. So a member whose force reverses under some load case is not merely being asked for the same number with the other sign — it is being designed against a different variable, and the same steel can carry seventy times more or less depending on a shape nobody chose for that purpose.

stability · Load reversal
The answer is continuous and the catalogue is not. Capacity bought against capacity required, over a real rolled series. The straight line is what a continuous section would give — exactly the moment asked for, and nothing can be bought on it. The staircase is what a catalogue gives: each tread is one section, each riser is the step to the next, and the vertical gap between the two is steel that is paid for and does nothing. The steps in this series run from 23% to 59% in plastic modulus, so the average waste is 15.0% and the worst is 46% — just above a riser, where the section below has been missed by a kilonewton-metre. The 1200 kNm marked buys a 686×254×125 at 1418 kNm, which is 85% utilised. Two things follow that a continuous treatment cannot see: the sensitivity of a design to an assumption is zero over most of a tread and enormous at a riser, and an optimisation that returns three significant figures is answering a question with twelve answers in it.

The answer is continuous and the catalogue is not

Every optimisation in this subject returns a number with three significant figures in it, and nothing with three significant figures can be bought. What can be bought is a rolled series whose steps are a quarter to a half apart, so the member that goes on the drawing is on average a tenth stronger than the one that was calculated and can be a third stronger for no reason at all.

sections · Available sections
The second moment of area is a function of direction. Second moment of area of an equal angle against the angle of the axis it is taken about, with the product of inertia beneath it. The maximum is 5.943 × 10⁶ mm⁴ and the minimum 1.523 × 10⁶, a ratio of 3.90, and they occur where the product of inertia passes through zero — at 45.0° from the drawn axis. The value the drawing suggests, 3.733 × 10⁶, is neither of them.

The axis a column buckles about

A strut buckles about the axis with the smallest second moment of area, and for a section with no axis of symmetry that axis is neither of the two on the drawing. An angle used as a strut is 2.45 times weaker than the number a designer reads off its own dimensions.

sections · Principal axes
The stub column a bearing stiffener makes, in plan. A plan through the girder at the bearing. The 8 mm web runs across; the pair of 100 × 12 stiffeners stands off it; and the shaded strip of web either side — 15ε t_w, or 98 mm each way — is the width that buckles with the stiffeners rather than independently of them. Together they are an area of 3962 mm² with a second moment of 9.01·10⁶ mm⁴ about the web's centreline, a radius of gyration of 48 mm over a buckling length of 900 mm — 0.75 of the depth, because the flanges hold the ends. That is a slenderness of 0.25, at which the column curve returns 0.98: the stub column reaches 98 per cent of its squash load, and the section's own strength is very nearly the whole answer.

A column nine hundred millimetres long

The patch-load check asks how much of a web a flange can spread a wheel over, and answers in a plate-buckling reduction that throws seven tenths of it away. A pair of stiffeners does not improve that answer. It replaces the question with a different one, from a different family, with a different failure in it.

stability · Patch loading

Named alongside it

The objects these essays reach for when they reach for this one.

SlendernessBucklingCritical loadEffective lengthLoad pathSection shapeBuilt-up columnEuler loadFree bodyOptimisationPrincipal axesSecond moment of area

All concepts