Critical load — where it appears
Named by 40 essays across 5 fields — each of them below, with the objects they name alongside it.
Strong enough and still falls over
A column can fail at a fraction of the load its material could carry, by going sideways. Buckling is a failure of stability rather than of strength, and it is decided by geometry.
The column that was never straight
Euler's load is the load at which a perfectly straight column becomes indifferent to being bent. No column is perfectly straight, so no column ever reaches it — and the load it never reaches can still be measured.
The brace that need not be strong
A brace holding a column at mid-height carries almost no force. What it has to be is stiff — and the stiffness required is exact, large, and reached at a knee past which more buys nothing at all.
The water that will not run off
A flat roof deflects, the deflection makes room for water, the water deepens the deflection. It is the same equation as a buckling column, with rain in place of the axial load.
The column that twists instead of bending
Euler's column has one mode. A real column has three, and which of them governs is settled by where the shear centre sits. A cruciform strut buckles by rotating about its own length at a load that does not change no matter how short it is made.
Held, and not held
One horizontal restraint at the head of a storey, carrying no vertical load whatever, moves the critical load of the columns beneath it by a factor of 2.89. Effective length is a property of the frame, not of the member.
Guessing the shape, and getting the load anyway
A column's buckling load can be had from a shape that is wrong everywhere, because the energy criterion is stationary at the true mode. The error in the load is the square of the error in the shape, and it is always high.
The column that had yielded before it was loaded
A real column sits below both of the two straight answers over the whole middle of the slenderness range, and the usual explanation — that it was not straight — is only half of it. The other half is that the flange tips had already yielded when it left the rolling mill.
The panel that carries more after it has failed
Everywhere else in this field a critical load is where the argument ends. A thin web is the exception — it buckles visibly, in waves anybody can see, and then goes on to carry nearly twice as much again by turning itself into a truss nobody drew.
The arch that leans instead of squashing
A masonry arch is asked whether a line of thrust fits inside it. A steel rib is asked a different question entirely: it is a column carrying an axial force along its whole length, and the mode it buckles in puts one half up and the other half down while the crown moves sideways.
Too tall for nothing but itself
Every critical load met so far has been applied at the top of a column. A mast carries a load that is zero at the top and largest at the base, the governing equation stops being harmonic, and the answer comes out as a number with no π in it — along with a maximum height that is almost the same for steel, aluminium and wood.
Held everywhere, and it forgets its length
A brace at a point divides a member's buckling length. A restraint spread along the whole member does something else — the member chooses its own number of half-waves, and past a few of them the critical load stops depending on the length at all.
Two ways of buckling at once
A thin-walled column can bow as a whole or ripple in its plates, and each has its own critical load. The received advice is that the worst arrangement is the one where the two are equal. The arithmetic says the opposite — at coincidence the interaction costs two per cent, and the expensive region is where the plates go first.
The pressure that needs no direction
Every buckling problem in this collection has had a load with a direction — a column pushed along its axis, a plate along its edge, an arch by what is on it. A buried pipe has none. The pressure is the same everywhere, it stays normal to the wall as the wall moves, and it does work on any change of shape that reduces the area inside.
The load that is really a lean
No frame is ever plumb. The columns are out of upright by something like a three-hundredth, and every tonne of gravity load standing on that lean has a horizontal component. The force that represents it is not a safety allowance — it is an exact statics substitution for a geometry nobody drew.
The load that moves with the twist
A beam about to buckle sideways is beginning to rotate, and everything attached to it rotates with it. A load hung from the top flange swings out over the side and drives the rotation on; the same load hung underneath swings back and stops it. Two identical beams, two different capacities, and the only difference is a height.
The tie that spends an afternoon as a strut
A tension member is chosen by its area and nothing else. A compression member is chosen by how that area is arranged. So a member whose force reverses under some load case is not merely being asked for the same number with the other sign — it is being designed against a different variable, and the same steel can carry seventy times more or less depending on a shape nobody chose for that purpose.
The stiffness the load takes away
Buckling is usually taught as an event — a critical load, a bifurcation, a mode. Written as a matrix it stops being an event at all. A compressive load subtracts a stiffness from the structure, the subtraction grows with the load, and the critical load is simply where what is left reaches zero.
The column that leans on its neighbours
A column with a pinned base and a pinned top has no lateral stiffness at all and cannot stand up alone, and yet thousands of them do. What holds them is the rest of the storey, and what it costs is paid by whichever columns do have stiffness — whose effective length rises as the square root of the load being leaned on them, straight off the end of every chart.
The load it cannot buckle under
Every stability calculation on this site rests on an assumption nobody states: that the load has a potential, so a critical load is where a total potential energy stops being a minimum. A load that turns with the structure it is pushing has no potential, and the static analysis of such a column returns no critical load at all — a determinant that never vanishes, for a column that fails at a perfectly finite one.
An average stiffness is not a safe stiffness
Euler's load belongs to a column of one EI. Give the same column two, and the temptation is to average them — which is wrong, and wrong in the unsafe direction by a quarter. Buckling weights stiffness by the square of the curvature of the mode, so the middle of a pinned column decides everything and the ends decide almost nothing.
The buckling load with no compression in it
Twist a straight bar hard enough and it snaps into a helix, with no axial load on it anywhere. The load at which that happens is 2πEI/L — first power of the length, and no shear modulus in it at all, so how stiff the bar is in torsion has nothing to do with the torque that buckles it in torsion.
The tube that flattens itself
Bend a tube and the compression on one face and the tension on the other are both running along a curve, so both push inward. The circle becomes an oval, the second moment falls, and the moment–curvature curve turns over at a limit point that needs no imperfection, no bifurcation and nothing to be sensitive to.
The shape of the diagram, and not its peak
A beam's lateral-torsional capacity is quoted against uniform moment, which is the one case a beam carrying a load never has. Change the shape of the moment diagram without changing its peak and the buckling moment moves by a factor of nearly three.
The best design is the most sensitive one
Take a fixed area of steel and roll it into a tube. Euler's load rises with the radius and local buckling falls with it, so the capacity has a maximum — and the maximum is exactly where the two failure modes arrive together, which is the one configuration imperfections hurt most.
The axis a column buckles about
A strut buckles about the axis with the smallest second moment of area, and for a section with no axis of symmetry that axis is neither of the two on the drawing. An angle used as a strut is 2.45 times weaker than the number a designer reads off its own dimensions.
Counted, not checked
A column with pinned ends and no bracing cannot buckle on its own, so nothing about it fails a stability check. It still carries load, and load with no stiffness attached lowers the buckling load of everything around it — which is why a gravity-only column is put on the frame model and never designed by itself.
The third root of the cubic
A column has three buckling loads and an Euler calculation finds two of them. The third is a twist about the shear centre, and for a section whose shear centre is not at its centroid the three cannot happen separately — so the answer is the lowest root of a cubic and can be a third below anything the two familiar modes report.
The lacing decides the force it has to carry
A perfectly straight column carries no shear, so the diagonals of a built-up column are resisting a force that exists only because the column is crooked. Computing it turns out to be circular — the shear is amplified by the very flexibility the lacing supplies — and the rule of thumb that replaces the calculation is wrong by a factor that grows as the lacing gets worse.
The buckle that will not spread out
A compression chord on a continuous restraint chooses its own number of half-waves and forgets how long it is. Give it the force it actually carries — a parabola, largest at midspan — and the number barely moves while the shape changes completely, which is the half that decides where the restraint has to be.
The bound from underneath
Rayleigh's quotient turns a guessed shape into a buckling load that is always too high. Divide the same guess differently — use the curvature its bending moment would cause instead of its own — and a parabola that was 21.6 per cent high is 1.3 per cent high. Add one more number that needs no guess at all and the load is caught from below as well, which is the only side of it an amplifier can safely use.
The bearing Engesser says has buckled
A member that is flexible in shear buckles below its Euler load, and there are two classical formulas for how far below. For a laced column they agree to a fraction of a per cent. For a battened column one gives nearly twice the other. For a laminated rubber bearing, Engesser's says it buckles at a fourteenth of the load it carries every day and Haringx's says it is safe by a factor of nearly three. They are not two theories. Put the axial load into Engesser's shear stiffness and it becomes Haringx's, exactly — so the whole disagreement is about which shear stiffness was measured.
The roof that ponds on its girders
A flat roof's joists sit on girders, and the water fills the sum of both their sags. Two members each half-way to ponding on their own are unstable together, and long before that the growth of the water is far larger than either member's own amplification says. AISC's simplified rule turns out to be a line of constant growth, and a member sized to a deflection limit has a ponding parameter proportional to its span — so a bay sized to L/240 under 1.5 kN/m² meets the rule up to 6 m, doubles its water at 12 and ponds at 24.5.
The hat that hides the lean
A hat truss on a core-and-frame building holds the top of the core, nearly doubles the building's critical load, and makes its top storeys look three or four times as stiff as they did. The storey check believes them. Under the hat the roof storey reads a sway factor of 15 and estimates 7 per cent of second-order drift; the building still buckles leaning, and the roof storey's true increase is 24 per cent. The hat turns the storey check from pessimistic to unsafe at exactly the storeys it was built to stiffen.
The trace that adds up every storey
A column's buckling load can be bounded from below by the traces of its flexibility, with no shape guessed. A sway frame has a flexibility too — one number per pair of floors — and its traces bound the frame's critical load factor from below and from above, closing in as more are taken: on a six-storey frame whose factor is 14.96, the first four give 14.07 to 16.39. But the first trace is Dunkerley's sum over the storeys, counting each as though its sway mode were the frame's, and it bounds a well-balanced frame worst of all: one over the number of storeys when every storey is alike, which is exactly when Eurocode 3's storey-by-storey estimate is exact.
The braces that have to hold each other
One brace at mid-height must have a stiffness of twice the column's load over the length it halves. Spread the same column over four braces and each one must be stiffer, not softer: 3.62 times the load over its segment, rising towards four with every brace added, because the shape the braces have to stop is a zigzag in which every brace point is pushed by both its neighbours. Braces that tie the column to itself instead of to the ground need one, however many there are. A row with surplus stiffness can carry one brace at two thirds of the ideal, but not one that is missing, and the force each brace has to resist grows with the count.
The deck the stays squeeze
Every stay of a cable-stayed bridge pulls the deck towards its tower, and the deck carries all those pulls as a compression that is largest at the tower — 95 MN in a 1,000 m span under 150 kN/m. The stays hold it up and hold it straight, as springs under a strut. The compression grows with the square of the span and the springs soften with it, so the factor on its own weight at which the deck would buckle falls as the span to the power one and a half: 41 at 300 m, 6.9 at 1,000 m, 2.3 at 2,000 m. A deck four times stiffer only doubles it, and the long stays' sag, which softens them for traffic, hardly enters.
The floor the columns lean on
A storey of pin-ended columns, every one a little out of plumb, leans on its floor, and the floor leans on a core. Count the floor as rigid and the core needs the sum of the columns' demands. A floor that shears in its own plane is a brace in series with the core, and the far columns lean on it before their push arrives. With a floor a hundred times stiffer per bay than a column's own sway softening, the storey's buckling factor falls from 4.0 to 1.5 and the core is asked for twice as much.
The wall that is made of weight
A drill pipe pushed down an inclined hole is kilometres long and has no Euler load worth the name, yet it carries 147 kN before it buckles. What holds it is the low side of the hole, and the only thing pressing it there is its own weight — a Winkler foundation with no spring in it, which a vertical hole does not have at all.
The push that cannot reach the end
A tube pushed inside a hole cannot buckle away — the wall stops it — so it winds into a helix whose pitch tightens as the push grows and which presses on the wall as the square of the push. Friction on that pressure has a startling consequence. Past a certain distance, no push at the near end, however large, delivers anything at the far one.
Named alongside it
The objects these essays reach for when they reach for this one.
BucklingEigenvalueEffective lengthStiffnessSlendernessImperfectionBracingGeometric stiffnessSecond-orderFree bodyMode shapeP-delta