Concept

Effective length — where it appears

The pin-ended column that would buckle at the same load, quoted as a length, and a property of the whole frame rather than of the member. It is a property of the whole frame rather than of the member, so a single restraint carrying no vertical load can change it by a factor of three.

Named by 25 essays across 4 fields — each of them below, with the objects they name alongside it.

The column curve. Failure load against slenderness, as a fraction of the squash load. A stocky column crushes; a slender one buckles at the Euler load; the crossover is where the two curves meet, and real columns fall below both near it.

Strong enough and still falls over

A column can fail at a fraction of the load its material could carry, by going sideways. Buckling is a failure of stability rather than of strength, and it is decided by geometry.

stability · Buckling
The ends decide the length that matters. Four columns of identical height and section, buckling under four sets of end conditions. The effective length factor is the fraction of the column that behaves like a pin-ended one, and the buckling load goes as its inverse square.

The ends decide the length that matters

Four columns of identical height and section, buckling at loads sixteen times apart. Nothing differs but what is holding the two ends.

stability · Effective length
The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached.

The load that makes itself worse

A structure that has leaned carries its weight off the axis, which makes it lean further. The amplification is one over one minus the load ratio, and it runs away long before the buckling load.

stability · Second-order
The length at which a beam stops being a beam. Elastic critical moment against the distance between lateral restraints, with the section's plastic capacity drawn across it. The two cross at 3803 — beyond that length the beam buckles sideways before it reaches the strength its cross-section has, and the capacity is set by the restraints rather than by the steel.

The beam that fails sideways

A deep narrow beam bending in its strong plane can, at a moment well below its capacity, swing out of that plane and twist. The failure has nothing to do with how much it can carry and everything to do with what is holding it.

stability · Lateral-torsional
A brace is a stiffness requirement, not a strength one. Critical load against brace stiffness for a pinned column braced at mid-height. The curve climbs from the unbraced Euler load of 9.87EI/L² and flattens at 39.48EI/L², which is the Euler load of the braced segment — past that the column buckles in a shape the brace does not obstruct, and further stiffness buys nothing. The knee is at about 159EI/L³. A stiffness of 60EI/L³ is marked, reaching 21.75EI/L².

The brace that need not be strong

A brace holding a column at mid-height carries almost no force. What it has to be is stiff — and the stiffness required is exact, large, and reached at a knee past which more buys nothing at all.

stability · Effective length
A cruciform has three critical loads, not one. The three critical loads of a cruciform in compression, against its length, with the load it actually buckles at drawn over them. At 3000 mm the flexural loads are 921 kN about the major axis and 921 kN about the minor, while twisting about the shear centre takes 700 kN. The lowest root is 700 kN, and the column twists. The shear centre is the centroid, so the three modes are independent and the envelope is simply the lowest of them. The governing mode changes at 3442 mm: below that length the column twists, above it, it bends — because the torsional resistance keeps a term that does not grow when the member is shortened, and the flexural loads have none.

The column that twists instead of bending

Euler's column has one mode. A real column has three, and which of them governs is settled by where the shear centre sits. A cruciform strut buckles by rotating about its own length at a load that does not change no matter how short it is made.

stability · Flexural-torsional
One restraint, and several times the load. The same portal — the same columns, the same beam, the same steel — buckling with its head held against sway and with its head free to sway. The braced frame's critical load is 16.46 EI/L² and the swaying one's is 5.69 EI/L², a factor of 2.89, and the effective length factor that comes out of each eigenvalue is 0.774 against 1.317. Both are eigenvalues of the assembled frame at a beam-to-column stiffness ratio of G = 1.00; the buckled shapes are the mode vectors themselves, drawn at 18 per cent of the storey height so that the movement can be seen.

Held, and not held

One horizontal restraint at the head of a storey, carrying no vertical load whatever, moves the critical load of the columns beneath it by a factor of 2.89. Effective length is a property of the frame, not of the member.

stability · Sway stability
Four guesses at one buckling mode. A pin-ended column, with four assumed shapes and the load each of them gives. The reference is a ten-term Ritz expansion solved as an eigenvalue problem, at 9.8696 EI/L² — which is π², as it must be. a half sine gives 9.870, its own sag shape gives 9.882, a mid-span sag gives 10.000, a parabola gives 12.000. Every one of them is high and none of them is low, because an assumed shape is a constraint on the column and a constraint can only stiffen it.

Guessing the shape, and getting the load anyway

A column's buckling load can be had from a shape that is wrong everywhere, because the energy criterion is stationary at the true mode. The error in the load is the square of the error in the shape, and it is always high.

stability · Stability energy
The one length a section carries into a column. Four profiles of equal area, with the radius of gyration r = √(I/A) drawn as the distance it is — a pair of lines either side of the centroid, at the depth the whole area would have to sit at to give the section the second moment it has. As a 4 m pin-ended column the same 3000 mm² of material carries between 7 and 3146 kN, in the ratio of the squares of those radii and of nothing else.

The one length a section takes into a column

A section has an area, a second moment, two section moduli, a shear centre and a torsion constant. A column has heard of exactly one of them, and it is none of those — it is the length √(I/A), which is where the whole area would have to sit to give the section the stiffness it has.

sections · Radius of gyration
How stiff a brace has to be before the frame stops swaying. The effective length factor of a swaying portal against the stiffness of a horizontal spring at its head. The curve starts at k = 1.317, the unbraced value, and falls to 0.774 — the factor for the same frame with its head held — at a brace stiffness of 23.2 EI/L³. Past that point the frame buckles in the non-sway mode, which the brace does not restrain, and further stiffness buys nothing at all. The threshold is worth stating as 1.41 N꜀ᵣ/L, which is the form the number is memorable in: for a storey carrying a thousand kilonewtons over four metres it is about 0.35 kN per millimetre of sway. Against the frame's own lateral stiffness of 12.0 EI/L³ it is a factor of 1.93.

The most dangerous day is before it is finished

A structure is analysed once, complete, with every restraint present. It spends weeks in states nobody drew — a beam landed with no deck on it holds 17% of the moment its section is worth, a frame not yet braced buckles at a third of the load it will, and a bolt not yet tightened is a pin where the analysis assumed a fixity.

stability · Erection stability
The arch does not squash; it leans. The first two buckling modes of the same rib, drawn against its undeformed shape at an exaggeration of a few hundred. The first, at w_cr L³/EI = 49.7, is antisymmetric: one half rises while the other falls and the crown moves sideways. The second, at 117.1, is symmetric — the whole rib settling. The two differ by a factor of 2.36, which is why an arch is braced against sideways movement of its crown rather than against the load it is carrying, and why a tied arch with a single hanger at midspan is doing nothing for the mode that governs it.

The arch that leans instead of squashing

A masonry arch is asked whether a line of thrust fits inside it. A steel rib is asked a different question entirely: it is a column carrying an axial force along its whole length, and the mode it buckles in puts one half up and the other half down while the crown moves sideways.

stability · Arch buckling
A brace on the wrong flange never gets there, however stiff it is. The critical moment of an 8 m beam against the stiffness of a single midspan brace, drawn three times for the three heights the brace could sit at. On the compression flange it climbs from 143 kNm to the two-half-wave plateau of 447 — the beam braced into two 4.0 m beams — and reaches 99% of it at 447 kN/m. At the shear centre it needs 2252 kN/m, 5.0 times as much. On the tension flange it never arrives at all: at the stiffness that would have done the job on the other flange it has bought a factor of 1.068, and a stiffer brace in the same place buys the same nothing. Past the plateau the beam stops using the brace, which is where the idea of an ideal stiffness comes from.

The brace on the wrong flange

A brace on a column has one property that matters, and it is stiffness. A brace on a beam has two, and the second decides whether the first is worth anything: put the identical restraint on the tension flange and it does not reach the answer at any stiffness whatever.

stability · Beam bracing
The restraint chooses the buckling length, and it is not the member's. A compression flange 12 m long held sideways not at points but everywhere, by a restraint of 0.35 N/mm per mm of length. Unrestrained it would buckle at 173 kN in a single half-wave, drawn faintly. Restrained it buckles at 1968 kN — 11.4 times as much — in two half-waves, because the sum n²π²EI/L² + kL²/n²π² has its minimum there and every other n is worse. The effective length that answer implies is 3555 mm, which is 0.30 of the member and is a property of the restraint rather than of the span.

Held everywhere, and it forgets its length

A brace at a point divides a member's buckling length. A restraint spread along the whole member does something else — the member chooses its own number of half-waves, and past a few of them the critical load stops depending on the length at all.

stability · Continuous restraint
The width nobody drew. A gusset plate with a brace bolted to it over 240 mm, and the width the profession has agreed to pretend is carrying the force. Everything else on this site arrives with a cross-section; a gusset does not, because it is a piece of steel with something attached somewhere in the middle of it and there is no geometry that says how much of it is working. The answer is the Whitmore section: assume the force spreads at 30° from the first fastener and take the width it has reached at the last, b_eff = w + 2L·tan30° = 367 mm. That is 4.08 times the width anything is actually attached to, and the rule comes from a 1952 master's thesis. It has since been checked against finite element work and holds to about ten per cent, which is fortunate, because moving the assumed angle by ten degrees moves the answer by 34%. On this plate the check that governs is not the stress the rule was written for: it is the Whitmore section buckles, at 721 kN against 1564.

The width nobody drew

Every other member in this collection arrives with a cross-section. A gusset plate does not — it is a piece of steel with a brace bolted to it somewhere in the middle, and no geometry says how much of it is working. The profession's answer is a thirty-degree spread from a 1952 master's thesis, it invents three quarters of the area being checked, and the check it was written for is not the one that governs.

connections · Gusset
The check that everything adds up, and the error it cannot see. Four versions of the same 2-bay, 3-storey frame, with the global equilibrium residual each one produces — the sum of the reactions against the sum of the applied loads, as a fraction of the applied total. It is the first thing every analysis prints and it is worth having: a lost restraint and a load entered in the wrong unit both show up immediately, at 6% and 24%, because both change what the structure is carrying. The fourth bar is the point. A member whose stiffness is wrong by a factor of ten redistributes the internal forces completely — the second bar shows the change in the member forces, 18% — and the global residual is exactly zero, because the wrong answer is still in equilibrium with the same loads. Equilibrium is one equation per degree of freedom of the whole body, and a stiffness error lives entirely in the many equations underneath it. A model can satisfy every equilibrium check ever devised and be a model of a different structure.

The stiffness the load takes away

Buckling is usually taught as an event — a critical load, a bifurcation, a mode. Written as a matrix it stops being an event at all. A compressive load subtracts a stiffness from the structure, the subtraction grows with the load, and the critical load is simply where what is left reaches zero.

stability · Geometric stiffness
Effective length is a property of the storey. The effective length factor of the one column that resists sway, against the total gravity load on the storey as a multiple of its own. At the left-hand end it carries the storey alone and its K is 1.99 — the 2.0 every chart gives a column fixed at the base and free to sway at the top, reproduced here by a route that never mentions a chart. Then columns are added that have pinned bases and therefore no lateral stiffness whatever. They contribute load and nothing else, so they cannot buckle on their own and they lower the load at which everything buckles together. K rises as the square root of the load ratio, exactly, and at the storey drawn — three leaning columns carrying 69% of the gravity load — it is 3.57. That is off the end of every published alignment chart, and the leaning columns themselves, which a designer would take at K = 1.0 for pinned ends, are at 2.54.

The column that leans on its neighbours

A column with a pinned base and a pinned top has no lateral stiffness at all and cannot stand up alone, and yet thousands of them do. What holds them is the rest of the storey, and what it costs is paid by whichever columns do have stiffness — whose effective length rises as the square root of the load being leaned on them, straight off the end of every chart.

stability · Storey buckling
The average is not the answer, and it is unsafe. Critical load of a pinned column whose middle third has been given a different stiffness, against the whole-column Euler load, with the two numbers a hand check reaches for beside it. The eigenvalue is taken from K − P·Kg over 24 elements, so nothing here is a formula for a stepped column — it is the same computation the uniform case gets. At a middle third of 0.50 times the rest the true load is 0.612 of Euler's, the arithmetic average says 0.832 and the weakest segment says 0.496. The average is high by 36% and it is high on the unsafe side, because the third of the column it is averaging over is the third where the mode has all its curvature. The weakest-segment answer is safe everywhere and wasteful by about as much.

An average stiffness is not a safe stiffness

Euler's load belongs to a column of one EI. Give the same column two, and the temptation is to average them — which is wrong, and wrong in the unsafe direction by a quarter. Buckling weights stiffness by the square of the curvature of the mode, so the middle of a pinned column decides everything and the ends decide almost nothing.

stability · Stepped column
A Pratt truss of 8 panels. A Pratt truss under equal panel-point loads. The joint equilibrium equations were assembled and solved; 14 members came out in tension, 13 in compression and 2 carrying nothing.

Halving the panel buys a shorter strut

Subdividing a truss into more panels of the same span and depth barely changes the chord forces, because the couple that carries the moment has not moved. What it changes is the length of every compression member, and a buckling capacity goes as the inverse square of a length.

structures · Truss

The axis a column buckles about

A strut buckles about the axis with the smallest second moment of area, and for a section with no axis of symmetry that axis is neither of the two on the drawing. An angle used as a strut is 2.45 times weaker than the number a designer reads off its own dimensions.

sections · Principal axes

Counted, not checked

A column with pinned ends and no bracing cannot buckle on its own, so nothing about it fails a stability check. It still carries load, and load with no stiffness attached lowers the buckling load of everything around it — which is why a gravity-only column is put on the frame model and never designed by itself.

stability · Second-order

The pinned base that is not pinned

A column base drawn as a pin is a plate bearing on grout, and a plate in contact over its whole length resists rotation whether anybody wanted it to or not. The stiffness it delivers depends on the axial load, so the assumption is one a frame can leave and re-enter as its loads change.

stability · Sway stability

The restraint that beats the gradient

A moment-gradient factor is worth up to 2.7 on a beam's critical moment and is tabulated everywhere. Holding the ends against warping is worth more, is achieved by a detail rather than by a load case, and appears in no table at all.

stability · Moment gradient

The third root of the cubic

A column has three buckling loads and an Euler calculation finds two of them. The third is a twist about the shear centre, and for a section whose shear centre is not at its centroid the three cannot happen separately — so the answer is the lowest root of a cubic and can be a third below anything the two familiar modes report.

stability · Flexural-torsional

A column nine hundred millimetres long

The patch-load check asks how much of a web a flange can spread a wheel over, and answers in a plate-buckling reduction that throws seven tenths of it away. A pair of stiffeners does not improve that answer. It replaces the question with a different one, from a different family, with a different failure in it.

stability · Patch loading

The buckle that will not spread out

A compression chord on a continuous restraint chooses its own number of half-waves and forgets how long it is. Give it the force it actually carries — a parabola, largest at midspan — and the number barely moves while the shape changes completely, which is the half that decides where the restraint has to be.

stability · Continuous restraint

Named alongside it

The objects these essays reach for when they reach for this one.

Critical loadBucklingSlendernessBracingEigenvalueFree bodyImperfectionGeometric stiffnessLateral-torsional bucklingStiffnessWarpingBuckled mode shape

All concepts