Capacity design — where it appears
Named by 8 essays across 5 fields — each of them below, with the objects they name alongside it.
The earthquake asks for a displacement
A structure a quarter as strong as the elastic demand does not deflect four times as far. It deflects almost exactly as far, yields on the way, and survives — which is why no ordinary building is designed for the force an earthquake would apply if it stayed elastic.
The part that is meant to be weak
A braced frame is stiff and has nowhere to yield. A moment frame yields everywhere and is soft. Move the two diagonals a metre apart along the beam and the whole storey shear has to pass through the segment between them — which keeps most of the stiffness and puts every yielding in one member the designer chose.
The steel that is stronger in a millisecond
Every strength quoted anywhere in this collection was measured at about a ten-thousandth of a strain per second, because that is what a testing machine does, and nothing on a drawing says so. Load the same steel a million times faster and its yield stress rises by a third.
The failure that is in the concrete
An anchor bolt is a steel component and its capacity is usually decided by something else entirely — a cone of concrete pulled out around it, failing in tension, in a material every other calculation on the project has assumed cannot take tension at all. The exponent in the capacity says so: it is not the square the geometry implies.
The force the brace leaves behind
Two braces meeting under a beam carry the storey shear as a tension and a compression whose vertical components cancel, so the beam above sees nothing. They cancel only while both braces are elastic. Once the compression brace buckles it sheds most of its force, the tension brace goes on to yield, and the difference is a point load at midspan that nobody applied.
The brace that yields both ways
An ordinary diagonal yields in tension at its full strength and buckles in compression at half of it, and the buckle leaves a hinge that does not straighten. Stop it buckling with a sleeve that carries no load at all and the loop becomes symmetric.
The force that is capped on purpose
Everywhere else in this collection friction is a nuisance whose value nobody controls, checked with a coefficient known to one figure. In a friction damper the inequality is the design intent — the device is specified so that a member behind it can never be asked for more than a stated force.
The fuse that protects the strand and not the wall
A rocking wall's tendon loses its prestress when it yields, so give it a fuse: a short link in series that yields first and is replaced afterwards. The strand then never passes 1,000 kN and stays elastic. But the fuse caps the restoring moment lower, so under the same 1.5 g pulse the wall rocks to 110 mrad instead of 89, and the line loses all its prestress just as the strand did. A new fuse gives the prestress back; the bars' stretch stays, and the next pulse takes the wall to 134 mrad.
Named alongside it
The objects these essays reach for when they reach for this one.
DuctilityHysteresisEnergy dissipationPlastic hingeBucklingLoad pathFree bodyLateral systemOverstrengthAnchorageBase plateBehaviour factor