Dynamics

The lining the mass must not crush

A wind-tuned mass inside a ring of hard stops strikes them two or three times in a moderate earthquake, each strike a blow of a seventh of its weight. Line the ring with a soft layer 80 mm thick and the strikes stop: the mass meets the lining instead and is pressed back at half the force. But a lining is not better for being softer. It has to stop the mass inside its own thickness, so it has a stiffness floor set by the speed the mass arrives at, and the best lining for a strong earthquake is three times stiffer than the best for a moderate one. Below the floor the mass drives straight through to the ring.

Assumes The only thing that stops it, The mass that helps by being late and The steel that is stronger in a millisecond.

The tuned mass of the ring the mass swings inside is a 2 per cent mass on a 4 s building, tuned and damped for the wind by Den Hartog’s rule. On a windy day it already swings ±0.40 m along the wind’s line — the stroke the wind has already spent — and a ring of stops 0.50 m in radius limits how far it can go. When an earthquake arrives across the wind the mass runs into the ring, and the stop long where the wind swings asked what shape the ring should have. Its answer was that a stop should be longest along the wind, where the mass already spends its time near the ends of its swing; and it ended on the other variable a stop has, which is what it is made of.

Every stop in those essays was a single hard bumper — a contact that would last 0.2 s if the mass bounced off it alone, so stiff that a 50 mm overlap pushes back with more than the mass’s own weight. In a moderate earthquake, 0.5 m/s² at its peak across the wind, the mass strikes that ring 2.6 times a record on average, each strike reaching about a seventh of the mass’s weight. Real tuned masses are often given a softer first layer — a rubber lining, a progressively stiffening buffer — so that a frequent, gentle excursion meets something forgiving and only a rare large one reaches the hard limit. That is the arrangement this essay analyses. The ring keeps its 0.50 m radius; inside it a lining 80 mm thick begins at 0.42 m, which is beyond the wind’s 0.40 m swing so that the wind alone never touches it.

Two springs met in turn

The lining is a spring in series with nothing, met first, and then in parallel with the hard ring once the mass has compressed it fully. Its stiffness is described the same way the hard bumper’s is, by how long a contact with it alone would last: the mass bouncing off a spring of stiffness kk is half a cycle of an oscillator, and lasts tc=πm/kt_c = \pi\sqrt{m/k}. So k/m=(π/tc)2k/m = (\pi/t_c)^2, and a lining whose contact alone would last 0.8 s has a stiffness per unit of the mass’s weight of (π/0.8)2/9.81=1.57(\pi/0.8)^2/9.81 = 1.57 per metre, against the hard ring’s (π/0.2)2/9.81=25.2(\pi/0.2)^2/9.81 = 25.2 per metre.

A stop with a soft lining: two springs met in turn. For a 2% tuned mass on a 4 s building, swung ±0.40 m along the wind by the wind, inside a ring of stops 0.50 m in radius: the stop's force on the mass, over the mass's weight, against how far the mass travels from its rest position. The hard ring alone pushes from 0.50 m at 25.2 times the mass's weight per metre of overlap. Lined with a layer 80 mm thick whose contact alone would last 0.8 s, the stop first pushes from 0.42 m at 1.57 weights per metre, 0.13 of the weight when the lining is fully compressed, and the hard ring then adds its own. Fully compressed, the lining has stored 0.05 J per kilogram of the mass — enough to stop it arriving at 0.31 m/s. The wind's swing reaches 0.40 m and never touches either.
Fig. 1 The stop’s push on the mass, as a share of the mass’s weight, against how far the mass has travelled from rest, for the hard ring alone and for the ring lined with a layer 80 mm thick whose own contact would last 0.8 s. The lining pushes gently from 0.42 m; the ring takes over at 0.50 m.

Fully compressed, the lining pushes with 1.57×0.08=0.131.57 \times 0.08 = 0.13 of the mass’s weight. That is the gentlest stop force the lining can offer at its far edge, and it is the number that matters for the anchorages of the lining, which see it at every contact. The force is not the whole story, though, because a stop’s job is not only to push but to bring a moving mass to rest. The lining’s stored energy at full compression is 12kt2\tfrac{1}{2}k t^2, which here is 0.5×1.57×9.81×0.082=0.0490.5 \times 1.57 \times 9.81 \times 0.08^2 = 0.049 J per kilogram of the mass. A mass arriving at the lining with a kinetic energy per kilogram of 12v2\tfrac{1}{2}v^2 is stopped within the lining only if 12v2≤0.049\tfrac{1}{2}v^2 \le 0.049, which is a speed of 0.31 m/s.

That speed is not large. The wind alone swings the mass ±0.40 m at very nearly the building’s period, so the mass crosses its rest position at about 0.40×2π/4.1=0.620.40 \times 2\pi / 4.1 = 0.62 m/s. An earthquake that adds to that motion can bring the mass to the lining at a good fraction of it. Whatever arrives faster than 0.31 m/s passes through the lining with energy left over and meets the ring.

Softer is not gentler

That is what makes the obvious design rule wrong. It is tempting to think of a lining’s softness as a measure of how gentle it is — the softer the material, the smaller the force at any given compression — and to choose the softest that will fit. A force-against-compression curve supports the thought. An energy balance does not.

The best lining is the softest one the mass cannot drive through. For a 2% tuned mass on a 4 s building, swung ±0.40 m along the wind by the wind, inside a ring of stops 0.50 m in radius, lined with a layer 80 mm thick: the peak stop force over the mass's weight, mean over ten records, against how long a contact with the lining alone would last — a longer contact is a softer layer. Dotted lines are the hard ring alone. Each earthquake has a best lining: at 0.5 m/s² a 1.00 s lining gives 0.07 against 0.14 unlined; at 1.0 m/s², 0.60 s gives 0.19 against 0.58; at 2.0 m/s², 0.45 s gives 0.53 against 0.98. Stiffer than that, the lining is itself a hard stop; softer, the mass crushes it and reaches the ring — at 2.0 m/s² a 2.0 s lining lets 18.0 strikes a record through against 1.4 at the best.
Fig. 2 The peak stop force over the mass’s weight, averaged over ten earthquake records, against the lining’s softness — the contact half-period it would give alone — for three earthquakes across the wind: 0.5, 1.0 and 2.0 m/s². The dotted lines are the hard ring alone. Every curve has a lowest point, and it moves to stiffer linings as the earthquake grows.

Each earthquake has a best lining. At 0.5 m/s² it is one of about 1.0 s, and the peak stop force falls from 0.14 of the mass’s weight with the hard ring alone to 0.07. At 1.0 m/s² the best is 0.6 s, and the peak falls from 0.58 to 0.19. At 2.0 m/s² the best is 0.45 s, and the peak falls from 0.98 to 0.53. Either side of each optimum the force rises again, for two different reasons. On the stiff side, the lining has become a hard stop itself, met earlier, and pushes hard over its short travel. On the soft side, the lining is crushed: the mass arrives with more energy than the lining can store in its thickness, passes through it and strikes the ring. At 2.0 m/s², a lining whose contact would last 2.0 s lets 18 strikes a record through to the ring, as many as no lining at all, while one of 0.45 s lets 1.4 through.

That is the first refutation above. A lining’s softness is useful only up to the point where it can still stop what arrives, and beyond that point the lining is a delay rather than a buffer.

The floor, by hand

The optimum can be predicted from the energy balance alone, before any earthquake is run.

The softest lining that can stop the mass is set by its speed. The longest contact half-period — the softest lining — that can bring the mass to rest within a layer 80 mm thick, against the speed the mass arrives at: the lining stores ½kt², the mass carries ½mv², and k/m = (π/tc)², so tc ≤ πt/v. A lining whose contact lasts 0.8 s stops a mass arriving at up to 0.31 m/s; one at 2.0 s, up to 0.13 m/s. Any faster and the mass reaches the hard ring with the difference. The layer's own damping, which the curve leaves out, lets it stop a little more.
Fig. 3 The softest lining that can bring the mass to rest within an 80 mm thickness, as the longest contact half-period it may have, against the speed at which the mass reaches it. A lining of 0.8 s stops arrivals up to 0.31 m/s.

Setting the lining’s stored energy equal to the mass’s, 12kt2=12mv2\tfrac{1}{2}k t^2 = \tfrac{1}{2} m v^2, gives k/m=(v/t)2k/m = (v/t)^2, and since k/m=(π/tc)2k/m = (\pi/t_c)^2 the condition is

tc≤πtv.t_c \le \frac{\pi t}{v}.

With t=0.08t = 0.08 m, a mass arriving at 0.2 m/s needs a lining of at most 1.26 s; at 0.4 m/s, 0.63 s; at 0.6 m/s, 0.42 s. Those three are close to the optima the records found at the three intensities — 1.0, 0.6 and 0.45 s — which says the records’ typical arrival speeds at the lining are a little over 0.25, 0.4 and 0.55 m/s. The rule is therefore a sizing method: estimate the speed at which the mass will reach the lining in the earthquake the lining is for, and choose the lining stiff enough to stop that speed in its thickness and no stiffer. The lining’s own damping, left out of the floor, adds a little to what it can stop, which is why the records’ optima sit slightly on the soft side of the estimate.

The rule also explains why a lining’s thickness is worth so much. The floor goes as πt/v\pi t / v: doubling the thickness doubles the softest lining that will do, and the peak force at a given arrival speed — which at the floor is kt=mv2/tk t = m v^2 / t — halves. A thick soft lining and a thin stiff one store the same energy; the thick one does it with half the force.

One strike, by hand

The averages hide a simpler comparison that can be made for a single arrival. A mass reaching a linear spring at speed vv compresses it until the spring’s energy equals the mass’s, and the peak force is then mvωm v \omega, with ω=π/tc\omega = \pi / t_c the contact’s own angular frequency — the moving-body version of twice the deflection for the same load. As a share of the mass’s weight, the peak is

Fmg=πvg tc.\frac{F}{m g} = \frac{\pi v}{g\, t_c}.

For a mass arriving at 0.3 m/s, the hard ring’s 0.2 s contact gives π×0.3/(9.81×0.2)=0.48\pi \times 0.3 / (9.81 \times 0.2) = 0.48 of the mass’s weight, and the lining’s 0.8 s contact gives 0.12 — a quarter, which is the ratio of the two contact times. The overlap at the hard ring would be vtc/π=19v t_c / \pi = 19 mm; in the lining, 76 mm, just inside its 80. That single strike is the whole case for a lining: four times the travel, a quarter of the force, the same energy.

Two things the single strike does not show are what the records add. First, arrivals are not all at 0.3 m/s; the faster ones overrun the lining, and for them the peak is the lining’s full 0.13 of the weight plus whatever the ring adds, which is why the records’ halving is less than the single strike’s quartering. Second, the lining is met on excursions that would have fallen short of the ring altogether, so it is touched more often than the ring was struck. Each of those contacts is a small force, but it is a force on the lining’s fixings and on the mass’s own guidance that the hard ring never applied at all. The fixings of a lining are therefore designed for many small cycles where the ring’s were designed for a few large ones — a fatigue question replacing a strength one, the usual price of making a blow gentle.

Every millimetre is taken from the free stroke

The ring has a radius set by the building: the room the mass is given is the room there is. A lining therefore does not add stroke; it takes some of the free stroke and makes it a buffer.

Every millimetre of lining is taken from the free stroke. For a 2% tuned mass on a 4 s building, swung ±0.40 m along the wind by the wind, inside a ring of stops 0.50 m in radius, at 1.0 m/s² across the wind: the strikes that reach the hard ring and all contacts of either kind, mean over ten records, against the lining's thickness, its contact half-period 0.8 s. The ring stays at 0.50 m, so the lining begins closer to the swing as it thickens: 100 mm separates the swing's end from the ring. Unlined, 9.1 hard strikes a record; 40 mm of lining, 5.2; 80 mm, 1.1. Contacts of any kind rise from 9.2 to 15.8, because the mass now meets something sooner.
Fig. 4 The strikes that reach the hard ring and the contacts of either kind, averaged over ten records at 1.0 m/s² across the wind, against the lining’s thickness, the ring held at 0.50 m and the lining’s contact at 0.8 s. A thicker lining is met sooner and more often, and lets far fewer strikes through.

At 1.0 m/s² the hard ring alone is struck 9.1 times a record. A 40 mm lining lets 5.2 strikes through, an 80 mm lining 1.1. Contacts of either kind rise as the lining thickens, from 9.2 a record to 15.8 at 80 mm, because the lining is met at a smaller radius: the mass now touches something on excursions that used to fall short of the ring. Those extra contacts are gentle — the lining pushes at most 0.13 of the weight at 0.8 s — but each is a moment during which the mass is not free.

The ring’s 0.10 m between the wind’s swing and the hard stop is the whole budget. The lining can have all of it, and the more it has the gentler it can be for the same stopping capacity, but a lining that fills the whole margin is met by every gust that swings the mass a little further than the design wind. The wind’s swing is the inner limit on the lining for the same reason it was the inner limit on the stop’s shape: the mass’s everyday motion has to stay clear of anything that would alter its tuning.

The blow, across intensities

The lining halves the blow until the earthquake outgrows it. For a 2% tuned mass on a 4 s building, swung ±0.40 m along the wind by the wind, inside a ring of stops 0.50 m in radius: the peak stop force over the mass's weight, mean over ten records, against the ground's peak acceleration, for the hard ring alone and lined with a layer 80 mm thick whose contact alone would last 0.8 s. At 0.50 m/s² it is 0.14 unlined and 0.07 lined; at 1 m/s² 0.58 and 0.25; at 3 m/s² 1.37 and 1.14. The lining takes the frequent, moderate contacts entirely; in a strong earthquake the mass arrives faster than the lining can stop and the hard ring takes the rest of the blow.
Fig. 5 The peak stop force over the mass’s weight, averaged over ten records, against the ground’s peak acceleration across the wind, for the hard ring alone and lined with the 80 mm, 0.8 s layer. The lining halves the blow in moderate earthquakes and takes less off it in strong ones.

With the lining fixed at 80 mm and 0.8 s, the peak stop force is halved at 0.5 m/s² (0.14 to 0.07), cut by more than half at 1 m/s² (0.58 to 0.25), and trimmed only modestly at 3 m/s² (1.37 to 1.14). One lining cannot be optimal across the range, because the floor depends on the arrival speed, and the arrival speed grows with the earthquake. A designer choosing one lining is choosing which earthquake it is for. A lining sized for the frequent, moderate event is soft enough to make that event’s contacts negligible and too soft for the rare strong one, where it becomes the first part of a strike rather than the whole of one. A two-stage buffer is the device that resolves this — soft first, stiffer behind — and this essay’s lining in front of a hard ring is the simplest version of it. A third stage between them would stop the middle range of arrivals as the lining stops the low one.

The second figure’s curves allow the compromise to be priced. A lining chosen for the middle earthquake, 1.0 m/s², has a contact of about 0.6 s. In the moderate earthquake it gives a peak stop force of 0.10 of the mass’s weight, against 0.07 for that earthquake’s own best lining and 0.14 for the ring alone; in the middle earthquake 0.19, its own optimum; in the strong one 0.59, against 0.53 for the best and 0.98 for the ring. Sized for the middle, the lining gives up a little at each end and keeps most of what either end’s optimum would have bought. The flatness of the curves near their lowest points is what makes that possible: a lining within a factor of about one and a half of its optimum stiffness costs little, and a lining off by a factor of three or more — the 1.5 and 2.0 s linings in the strong earthquake — costs almost everything.

The time spent leaning, and the building’s indifference

The price of a gentle stop is a long one. For a 2% tuned mass on a 4 s building, swung ±0.40 m along the wind by the wind, inside a ring of stops 0.50 m in radius: the seconds of each 40 s record the mass spends touching its stop, mean over ten records, against the ground's peak acceleration, hard ring alone and lined with a layer 80 mm thick whose contact alone would last 0.8 s. At 1 m/s² the mass leans on the stop 2.2 s unlined and 9.1 s lined. While it does, the lining's spring adds to the mass's own and retunes it, yet the building's peak displacement in plan hardly moves — 250 mm unlined against 251 mm lined — because a 2% mass touching its stops has already given up most of its effect on the building in an earthquake.
Fig. 6 The seconds of each 40 s record the mass spends in contact with its stop, averaged over ten records, against the ground’s peak acceleration, hard ring alone and lined. A gentle stop is a long one: the lined mass leans on it several times as long.

A contact with a soft lining lasts much longer than a strike on the hard ring, and there are more of them. At 1 m/s² the mass touches the hard ring for 2.2 s of a 40 s record; lined, it is in contact for 9.1 s. During those seconds the lining’s spring acts in parallel with the mass’s own tuning spring — at 0.8 s the lining is more than six times stiffer than the mass’s suspension, whose own half-period is about 2 s — so the mass is substantially detuned while it leans. The earlier essays established that a tuned mass is effective only while it moves freely, and the lining takes away free time.

The building does not notice. Its peak displacement in plan at 1 m/s² is 250 mm with the hard ring and 251 mm with the lining. That is the second refutation. The retuning is real, and so is its irrelevance: a 2 per cent mass tuned for the wind has, by the time an earthquake drives it into its stops, already given up most of its usefulness to the building, as the tuned mass that sits out the earthquake found. What the lining protects is not the building. It is the mass, its stops and their anchorages, and the people near them, who would hear and feel a hard strike every time a moderate earthquake passes.

What the lined ring rests on

The lining is a linear spring with the restitution of the hard bumper. A real elastomer stiffens as it compresses and dissipates more energy than a dashpot of the same restitution at slow contacts. A stiffening lining approaches the two-stage behaviour by itself, and the floor argument still holds for the energy it can store within its thickness, which is the area under its force-compression curve rather than 12kt2\tfrac{1}{2}kt^2.

The building is two modes, the mass a point, the ring a circle. The models of the earlier essays, with the same ten filtered earthquake records, scaled to their peak ground acceleration and run with the wind already blowing. The averages over ten records are averages over a small sample; their ranking of linings is stable from record to record, their exact values are not.

The lining pushes along the radius. Its friction against the mass, which would add a tangential force at every contact and some damping of the mass’s motion along the ring, is left out, as it was for the hard ring.

A stop is an energy absorber with a thickness

The general lesson is the one the weight that was dropped drew from an impact factor: what stops a moving body is energy capacity, and energy capacity is a force times a distance — the accounting the only thing that stops it applied to a resonance, here applied to a single blow. A soft buffer reduces the force by increasing the distance, and the distance is exactly what the building cannot give it. So the buffer is a trade within a fixed thickness, and its optimum is the softest one that still has the energy to stop the arrival — which makes it the stiffest one that is still soft. The same arithmetic chooses a ship’s fender, a lift’s buffer and a vehicle’s crash cushion: each is sized to a design arrival speed and a stroke, and none is chosen by softness. The forging that cushions the blow showed the same trade from the other side, where a soft layer between a hammer and its anvil spreads the blow because it has the thickness to.

For a tuned mass this changes the question a designer asks of its stops. Not “how soft can the buffer be?” but “at what speed will the mass arrive, in which earthquake, and how much of the free stroke can be spent stopping it?”

Still open: a lining that is a damper

Every lining here stores the energy it takes and gives most of it back: it is a spring with a modest dashpot, and the mass rebounds. Stops are also built as hydraulic buffers, whose force rises with the speed of compression and which return almost nothing. A rate-dependent stop would be gentle with a slow arrival and firm with a fast one without needing a second stage, and its energy capacity would no longer be fixed by its thickness. Whether such a stop, sized for the same 80 mm, would let the mass’s strikes in a strong earthquake through at all — and whether the energy it dissipates at each contact would, for once, make the mass’s time against its stops useful to the building rather than merely harmless — needs the stop’s force as a function of speed and a record of every contact’s energy, which no model here has.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

The objects this essay names

Each one links to every other essay that touches it.

DampingEnergy methodGround motionImpactRestitutionStiffnessStrain energyStrokeTuned mass damper