Stability

The ground that holds the tube round

A thin steel tube bent along its length flattens into an oval, and Brazier's limit — 796 kN·m for a 1.2 m tube with a 2.5 mm wall — is where the flattening wins. Bury it, and the soil pressing on its sides resists every millimetre of that oval. In ground as stiff as an ordinary compacted fill the limit rises sixteenfold, far past the moment at which the wall itself buckles, so a buried tube is never governed by Brazier at all. What the ground decides instead is the oval the cover's own weight makes before anything bends, and that is set by the soil and hardly by the tube.

Assumes The tube that flattens itself and The pressure that needs no direction.

The tube that flattens itself found Brazier’s limit: a long thin tube bent along its length is squeezed into an oval by the curvature of its own stresses — the transverse component every stress in a curved wall has, which is how a surface carries by being curved — the oval costs it second moment, and the moment it can carry turns over at a flattening of two ninths of the radius with no imperfection anywhere in the story. Three kilopascals that halve a tube in bending added a uniform pressure, which changes only how stiffly the ring resists the oval, and the oval the pressure brings a pressure that varies round the tube, whose second harmonic does work on the oval directly. Its first example was a buried tube, with more soil on its crown than on its sides, and its last section admitted that it had been unfair to it: the ground does not only push. It pushes back.

Soil moved by a wall pushes harder; soil the wall moves away from presses less. A ring flattening into an oval pushes its sides out into the ground and draws its crown and invert in, and the ground resists both. So the ground loads the ring with an oval and then resists the oval it has made, and the question that essay left is which of the two the bending limit is set by.

The ground as a spring on the oval

The energy argument of the earlier essays carries over with one term added. Per unit length, the bent tube stores bending energy 12EI0(1−32ζ)κ2\tfrac{1}{2}EI_0(1 - \tfrac{3}{2}\zeta)\kappa^2, where ζ\zeta is the flattening as a share of the radius; the ring resists the oval with 12Kringζ2\tfrac{1}{2}K_{ring}\zeta^2, Kring=9πD/rK_{ring} = 9\pi D/r for a wall of plate rigidity DD; and the overburden’s second harmonic does work FζF\zeta on it, F=πq2r2F = \pi q_2 r^2. The ground adds a spring. If a radial movement ww of the wall is resisted by a pressure k wk\,w, the two-lobed oval w=ζrcos⁡2θw = \zeta r\cos 2\theta stores

12∫02πk (ζrcos⁡2θ)2 r dθ=12 πkr3 ζ2,\tfrac{1}{2}\int_0^{2\pi} k\,(\zeta r \cos 2\theta)^2\, r\,d\theta = \tfrac{1}{2}\,\pi k r^3\,\zeta^2,

so Ksoil=πkr3K_{soil} = \pi k r^3, and with k=E′/rk = E'/r for a modulus of soil reaction E′E', Ksoil=πE′r2K_{soil} = \pi E' r^2. The ground simply adds to the ring’s own stiffness against the oval.

Everything the earlier essays derived then follows with K=Kring+KsoilK = K_{ring} + K_{soil} in place of KringK_{ring}. The overburden’s oval is ζ0=F/K\zeta_0 = F/K, the flattening at the limit 2/9+2ζ0/32/9 + 2\zeta_0/3, and the limit itself

Mlim=MB KKring (1−32ζ0)3/2,M_{lim} = M_B\,\sqrt{\frac{K}{K_{ring}}}\,\Bigl(1 - \tfrac{3}{2}\zeta_0\Bigr)^{3/2},

with MBM_B the bare tube’s Brazier moment. The square root is the ground’s gift and the bracket is the cover’s cost.

The ground holds the section round while the tube bends. Moment against curvature for a 1,200 mm steel tube with a 2.5 mm wall bent along its length: bare and in air, where the section flattens into Brazier's oval and the moment turns over at 796 kN·m; and buried under 1.5 m of fill in ground of modulus of soil reaction 0.05, 0.3 and 3.0 MPa, where the ground pushes back on the flattening sides and the turnover rises to 1,375, 3,827 and 12,428 kN·m. The wall yields at 1,004 kN·m and buckles locally at 877, so in all but the loosest ground the wall's own limit arrives first.
Fig. 1 Moment against curvature for the 1.2 m tube with a 2.5 mm wall: bare and in air, and buried under 1.5 m of fill in ground of modulus of soil reaction 0.05, 0.3 and 3 MPa. In air the moment turns over at 796 kN·m; buried, the turnover moves far above the wall’s own limits.

The numbers for the tube of the earlier essays — 1.2 m across with a 2.5 mm wall, r/t=240r/t = 240 — make the scale plain. The ring’s own resistance to the oval is Kring=13,800K_{ring} = 13{,}800 N per millimetre of length. Ground with a modulus of soil reaction of 3 MPa, an ordinary compacted fill, adds π×3×6002=3.39×106\pi \times 3 \times 600^2 = 3.39 \times 10^6: two hundred and forty-five times the ring’s. The square root of the sum is 15.7, and the bare tube’s 796 kN·m becomes 12,428 under 1.5 m of cover. In loose ground, 0.3 MPa, it is 3,827; even at 0.05 MPa, 1,375.

The limit by hand

The 12,428 kN·m can be had on the back of an envelope, and doing so shows where each factor comes from. The tube’s plate rigidity is D=Et3/12(1−ν2)=205,000×2.53/(12×0.91)=293,000D = Et^3/12(1 - \nu^2) = 205{,}000 \times 2.5^3 / (12 \times 0.91) = 293{,}000 N·mm, so the ring resists the oval with Kring=9πD/r=13,800K_{ring} = 9\pi D/r = 13{,}800 N per millimetre. The ground at E′=3E' = 3 MPa adds πE′r2=3.39×106\pi E' r^2 = 3.39 \times 10^6. Their sum over the ring’s is 246.5, whose square root is 15.7. The cover’s second harmonic, q2=0.5×0.018×1,500/2=6.75q_2 = 0.5 \times 0.018 \times 1{,}500/2 = 6.75 kPa, does work F=πq2r2=7,630F = \pi q_2 r^2 = 7{,}630 N on the oval, which flattens the tube by F/K=0.0022F/K = 0.0022 before it is bent; the bracket (1−1.5×0.0022)3/2(1 - 1.5 \times 0.0022)^{3/2} is 0.995. So Mlim=796×15.7×0.995=12,430M_{lim} = 796 \times 15.7 \times 0.995 = 12{,}430 kN·m.

The arithmetic also says why the bare tube under the same cover is impossible. With no ground, F/Kring=7,630/13,800=0.55F/K_{ring} = 7{,}630/13{,}800 = 0.55: the cover alone would flatten the ring by more than half its radius — two and a half times the two ninths at which a bent tube’s section gives way, close to the two thirds at which the energy model itself stops meaning anything, and far beyond any shape a pipe could survive. A 1.2 m steel tube with a 2.5 mm wall cannot be buried under a metre and a half of soil without the soil holding it round. It is a structure only because the ground is part of it.

Almost any ground is enough

Brazier’s limit is one of three things that can end a tube’s bending. Its wall yields at fyπr2tf_y \pi r^2 t, 1,004 kN·m here, and buckles locally where the compression in its thin wall reaches a knocked-down shell buckling stress — 877 kN·m with the knockdown of 0.6 the earlier essays used. Bare, the tube’s 796 kN·m arrives first. Buried, the question is how little ground it takes to change that.

Almost any ground lifts the ovalisation limit past the wall's. Brazier's ovalisation limit for a 1,200 mm steel tube with a 2.5 mm wall against the ground's modulus of soil reaction, unburied and under 1.5 m of fill, beside the moments at which its wall yields (1,004 kN·m) and buckles locally (877). The ground's resistance to the oval adds to the ring's own, and the limit rises as the square root of the total. With no cover the limit passes local buckling at a modulus of 0.003 MPa; under 1.5 m, whose weight has already flattened the tube a little, at 0.03 MPa. A dumped, uncompacted fill is several times stiffer than either.
Fig. 2 Brazier’s limit against the ground’s modulus of soil reaction, on a logarithmic scale, unburied and under 1.5 m of cover, beside the moments at which the wall yields and buckles locally. The limit passes local buckling at a modulus of 0.003 MPa unburied and 0.03 MPa under the cover.

Very little. With no cover, a modulus of 0.003 MPa — three kilopascals of resistance per unit of strain, a thousandth of a compacted fill — lifts the limit past the wall’s 877 kN·m. Under 1.5 m of cover it takes 0.03 MPa, ten times as much, because the cover’s weight has already flattened the tube and spent some of the margin. A dumped, uncompacted fill has a modulus of a few tenths of a megapascal. Any tube actually surrounded by soil is past the point at which Brazier can govern.

That is the first refutation above, and it changes what a buried tube’s bending check is about. A designer of a pipe in air, or of a tube on supports, has three limits to compare. A designer of a buried pipe has two, the wall’s, and a third that has moved out of reach; the soil’s contribution to bending capacity is not a refinement of the Brazier check but its removal.

The oval the cover makes, before anything bends

What the ground cannot remove is the oval its own weight makes. The vertical pressure on the crown is the cover’s weight, γH\gamma H; the lateral pressure on the sides is a fraction K0K_0 of it; the difference has a second harmonic q2=(1−K0)γH/2q_2 = (1 - K_0)\gamma H/2 that pushes in at crown and invert and lets the sides out. That oval exists before the tube is bent at all, and on a flexible pipe it is the deflection a designer is actually asked to limit.

The weight's own oval is set by the ground, not by the tube. The flattening the overburden gives a 1,200 mm steel tube with a 2.5 mm wall before it is bent, as a share of the radius, against the depth of cover, in ground of modulus of soil reaction 0.2, 0.7 and 3.0 MPa. Under 1.5 m it is 3.18, 0.95 and 0.22 per cent; under 5 m, 10.60, 3.16 and 0.75. Once the ground's stiffness outweighs the ring's, the flattening is very nearly (1 − K₀)γH/(2E′) — dashed — with no property of the tube in it at all. A common limit on a flexible pipe's deflection is five per cent of its diameter.
Fig. 3 The flattening the overburden gives the tube before it bends, as a share of its radius, against the depth of cover, in ground of modulus 0.2, 0.7 and 3 MPa. The dashed lines are (1−K0)γH/(2E′)(1 - K_0)\gamma H/(2E'), which contains no property of the tube. Five per cent of the diameter is a common limit on a flexible pipe’s deflection.

Under 1.5 m of cover the tube is flattened by 3.18 per cent of its radius in ground of 0.2 MPa, 0.95 in 0.7 MPa and 0.22 in 3 MPa. Under 5 m, by 10.6, 3.16 and 0.75. Once the ground’s stiffness dwarfs the ring’s — which it does for this tube in any ground at all — ζ0=πq2r2/K\zeta_0 = \pi q_2 r^2/K reduces to

ζ0≈q2E′=(1−K0) γH2E′,\zeta_0 \approx \frac{q_2}{E'} = \frac{(1 - K_0)\,\gamma H}{2E'},

the second harmonic of the overburden over the ground’s stiffness. The tube has dropped out. For 1.5 m of cover weighing 18 kN/m³ with K0=0.5K_0 = 0.5, q2=6.75q_2 = 6.75 kPa, and in 3 MPa ground ζ0=6.75/3,000=0.22\zeta_0 = 6.75/3{,}000 = 0.22 per cent: the figure’s value.

That is the second refutation. The worry that a stiff, well-compacted backfill loads a flexible pipe harder gets the mechanism backwards: the oval is made by the difference between vertical and lateral pressure, which the backfill’s weight sets whatever its stiffness, and the stiffness resists it. Compaction does increase the lateral pressure on the sides somewhat, which reduces q2q_2, and that helps too. The quantity a buried flexible pipe’s deflection depends on is the ground, and Spangler’s formula for it, built on a different calibration of E′E', has the same structure for the same reason.

The cover’s weight, against the limit

The cover's weight erodes the limit slowly. Brazier's ovalisation limit for a 1,200 mm steel tube with a 2.5 mm wall against the depth of cover, in ground of modulus of soil reaction 0.2, 0.7 and 3.0 MPa. The overburden flattens the tube before it bends and the limit falls as the three-halves power of what is left, but the ground's stiffness has multiplied it first: in 0.7 MPa ground it is 6,052 kN·m under a quarter of a metre and 5,396 under 8 m, against a wall that buckles locally at 877.
Fig. 4 Brazier’s limit against the depth of cover in ground of modulus 0.2, 0.7 and 3 MPa. The cover’s oval erodes it slowly; the ground’s stiffness has already multiplied it many times.

The cover’s weight lowers the limit through the bracket (1−32ζ0)3/2(1 - \tfrac{3}{2}\zeta_0)^{3/2}, and the bracket moves slowly. In 0.7 MPa ground the limit is 6,052 kN·m under a quarter of a metre and 5,396 under 8 m, a loss of a ninth for thirty times the cover. In 0.2 MPa ground the erosion is faster, and under 8 m the cover’s own oval is past anything a pipe would be allowed. The weight never brings the bending limit down to the wall’s; long before it could, the tube has failed the deflection check the previous figure drew.

So the answer to the question the earlier essay asked — whether a buried thin tube’s bending limit is set by the soil’s weight or by its stiffness — is neither. Its bending limit is set by its wall. Its weight-and-stiffness question is a deflection question, and it is answered by the ratio of the cover’s pressure difference to the ground’s modulus.

The tubes that need the ground need little of it

Only a slender tube needs the ground, and it needs almost none. The modulus of soil reaction, in kilopascals, at which a 1,200 mm tube's ovalisation limit reaches the lesser of its yield and local buckling moments, against its radius over its wall, unburied and under 1.5 m of cover. Unburied, a tube up to about 200 times its wall in radius needs nothing: its wall gives out first. Beyond that it needs at most 3.4 kPa, near 220, and less as it thins — 0.04 kPa at a thousand — because Brazier's moment and the local buckling moment both scale as the radius times the wall squared, while the ring's own resistance to the oval falls as the wall cubed. Under 1.5 m the ground must first hold the overburden's oval, and the need is set by the cover: 26 kPa at 240, 13 at a thousand. A loose fill offers hundreds.
Fig. 5 The modulus of soil reaction, in kilopascals, at which a 1.2 m tube’s Brazier limit reaches its wall’s limit, against its radius over its wall thickness, unburied and under 1.5 m of cover.

The figure turns the question round: how stiff must the ground be for Brazier to stop mattering, as the tube gets thinner? Unburied, a tube up to about two hundred times its wall in radius needs nothing — its wall yields or buckles before its section flattens. Beyond that it needs a modulus that peaks at 3.4 kPa near r/t=220r/t = 220 and then falls, to 0.04 kPa at a thousand. The thinner tube needs less because of how the three quantities scale. Brazier’s moment goes as Ert2E r t^2, and so does the local buckling moment once the wall is too thin to yield, so their ratio stops depending on the slenderness; the ring’s own resistance to the oval, which the ground has to supplement by a fixed fraction, goes as t3/rt^3/r and falls fast. Under 1.5 m of cover the need is set by the cover’s oval rather than by bending, 26 kPa at r/t=240r/t = 240.

It is a counter-intuitive result and worth stating plainly: the more a tube depends on the ground, the less ground it needs. A very thin tube is so soft as a ring that a trivial soil spring dominates it. What a thin tube needs from the ground is not stiffness for bending but stiffness against its cover’s oval, and that is the γH/E′\gamma H/E' of the previous section.

Does the crown stay on the ground?

The spring that pushes back on both lobes is only honest while the soil is in contact all round. Where the oval moves the wall away from the soil — at crown and invert, which the flattening draws in — the soil’s pressure falls by kζrk\zeta r, and it can only fall as far as the overburden pressure that was there; past that the crown would leave the ground and that part of the spring would vanish.

The crown stays on the ground as long as there is ground above it. For a 1,200 mm steel tube with a 2.5 mm wall in ground of modulus of soil reaction 3.0 MPa: the flattening at the moment that governs it — local buckling of the wall — against the depth of cover, beside the flattening at which the soil over the crown, unloaded by the oval moving away from it, would have shed the whole of the overburden's pressure and the crown would leave it. Under 1.5 m the tube reaches its governing moment at 0.27 per cent of its radius and would leave the ground at 0.90; the spring that pushes back on both lobes is honest throughout. With no cover there is no pressure to shed, and only the sides can push.
Fig. 6 For ground of 3 MPa: the flattening at the moment that governs the tube — local buckling of its wall — against the depth of cover, beside the flattening at which the crown would have shed the whole of the overburden’s pressure and left the ground.

Under 1.5 m of 3 MPa ground the tube reaches its governing moment at a flattening of 0.27 per cent of its radius and would leave the ground at 0.90; at every depth drawn the first comes before the second, so the two-sided spring holds to the end. The margin grows with depth, because the overburden that the crown can shed grows with the cover while the flattening at the governing moment barely moves. With no cover at all there is nothing to shed: the crown has no soil pressing on it, only the sides push, and the ground’s stiffness is roughly halved — which, by the square root, still leaves an unburied tube surrounded at its sides with more than ten times the ring’s stiffness in any real ground.

What a buried thin tube is checked for

Put together, the figures reorder a buried tube’s checks. The bending check that matters is the wall’s: local buckling under the longitudinal compression of the bending, knocked down for imperfection, and yielding for a thicker wall. Brazier’s ovalisation, which a tube in air must be checked for whenever its radius passes about two hundred times its wall, falls out. In its place comes a deflection check that has nothing to do with bending: the cover’s own oval, (1−K0)γH/2E′(1 - K_0)\gamma H/2E', against a limit of a few per cent of the diameter. And a construction check comes with it, because the ground that does all of this is placed by people: the modulus E′E' in every formula here is a property of how the fill beside the pipe was compacted, and a pipe whose haunches were left loose has a much smaller E′E' just where the oval pushes.

The order is the reverse of a tube in air, where the ring’s own stiffness is all there is and the oval is a strength question. Buried, the oval becomes a stiffness question about the ground, and the strength question is handed back to the wall. The same steel tube, with the same wall, is governed by different mechanisms on either side of the trench’s edge — which is why a pipe laid across a gap in the ground, a culvert’s exposed end or a pipe bridge, is the place to look for a Brazier failure in a system that is otherwise buried.

What the ground model leaves out

The soil is a Winkler spring. Each point of the wall is resisted by the soil next to it alone, with a modulus taken as E′/rE'/r. Real ground spreads a load, and its resistance to an oval depends on the oval’s wavelength — the reason the pressure that needs no direction found the buried ring buckling into four or five lobes rather than two. For the two-lobed Brazier oval, the longest wavelength, a Winkler spring is a fair description; the exact modulus is the most uncertain number in the calculation, and the conclusions hold over two orders of magnitude of it.

The tube is long, its ends free to ovalise. As in the earlier essays, the oval needs a length of order rt\sqrt{rt} to develop. A buried pipeline is long, so this is the easy assumption here.

The bending is in the vertical plane. Settlement into a trench bends a pipe vertically, which lines the bending’s flattening up with the cover’s — the least favourable alignment, and the one drawn. A pipe bent sideways, round a bend in its route, has the cover’s oval at right angles to the bending’s, and gains from it as the oval the pressure brings showed.

The wall’s local buckling is a knocked-down shell value. The 877 kN·m that governs every buried case is the classical buckling stress reduced by 0.6; a wall with larger imperfections buckles sooner, and that is now the check that matters. A third of what the theory promised is the measure of how uncertain it is.

A load that brings its own support

The general shape of this result recurs wherever a load is delivered by a medium that also resists. Water pressure on a submerged hull, the air inside a membrane held up by the air inside, soil on a buried pipe: in each, the thing that loads the structure is a continuum, and the same continuum’s stiffness acts on any deformation the structure makes. Whether the load or the support dominates depends on which harmonic of the deformation is asked about. For a buried tube in bending the ground is overwhelmingly a support, because the Brazier oval is a large, slow deformation that pushes a lot of soil; for the same tube’s deflection under its own cover the ground is load and support at once, and their ratio is the whole answer.

The design consequence is a shift in what the trench specification is for. Its compaction is not there to stop the pipe flattening in bending, which almost any soil does; it is there to limit the cover’s own oval, which goes as one over the modulus. A beam on the ground already showed that a Winkler foundation turns a structural question into a question about the ground’s stiffness. A buried tube is the case where it turns one failure mode off entirely.

Still open: the tube that settles unevenly

Every case here bends a tube that is uniformly buried, with the same cover and the same ground along its length. The bending in a buried pipe usually comes from the ground being uneven — a soft patch, a trench that settled more in one place — and there the cover’s oval and the ground’s stiffness vary along the pipe exactly where the curvature is concentrated. Whether a tube over a soft patch is weakest where its ground is softest, with a lower ovalisation limit and a larger cover oval at the same section as its peak moment, and whether that can bring Brazier back into a buried pipe over a short enough soft length, needs the pipe as a beam on a varying foundation with its section’s oval solved along it, which this ring model does not have.