Concept

Local buckling — where it appears

Instability of one plate element of a section rather than of the member as a whole, which caps the stress the whole section can reach. It interacts with the member's overall buckling rather than merely adding to it, and the interaction is worst where the local critical load is well below the global one.

Named by 19 essays across 5 fields — each of them below, with the objects they name alongside it.

The same material, four ways. Four cross-sections of identical area, so identical weight and cost, with the second moment of area computed from each profile's own geometry. Only the arrangement differs, and the stiffest is many times the flattest.

The same steel in a different shape, and a factor of forty

Four sections of identical area, identical weight and identical cost. The stiffest is dozens of times the stiffest of the flattest, and the only thing that changed was the arrangement.

sections · Section shape
Where the class limits come from. The width-to-thickness ratio at which two kinds of plate reaches its own elastic critical stress at the yield stress, for three steel grades. A flange outstand (buckling coefficient 0.43) derives to 18.6, 15.2, 13.3 at 235, 355, 460 N/mm², against quoted limits of 14.0, 11.4, 10.0; A web, in bending (buckling coefficient 4) derives to 56.8, 46.2, 40.6 at 235, 355, 460 N/mm², against quoted limits of 42.0, 34.2, 30.0. The derived number is the larger every time, and by the same factor at every grade — flange outstand 1.33, web, in bending 1.35 — because both the derivation and the quoted limit go as one over the root of the yield stress. A constant ratio is what a fixed knockdown looks like: the derivation is for a perfect plate and the quoted limit is for a rolled one, carrying residual stress and not quite flat.

The section that cannot reach its own strength

A section classification looks like a table of arbitrary numbers. Set a plate's buckling stress equal to the yield stress and the numbers fall out of the plate buckling formula — larger than the quoted ones by a constant factor, at every grade.

materials · Section classification
A buckled panel is a truss that nobody drew. A 1000 × 1000 panel of 6 mm web, at d/t = 167. It buckles in shear at 63.8 N/mm², which is 383 kN — and it then carries 696 kN, 1.82 times as much, because the tension diagonal takes over from the compression one that has gone. The band runs at 22.5° with a membrane stress of 252 N/mm² over a width of 541 mm, and it pulls on the flange at 221.3 N per millimetre of its length. A web that never buckled at all would have reached 953 kN, so the panel ends at 73% of a stocky web's capacity on a fraction of its steel.

The panel that carries more after it has failed

Everywhere else in this field a critical load is where the argument ends. A thin web is the exception — it buckles visibly, in waves anybody can see, and then goes on to carry nearly twice as much again by turning itself into a truss nobody drew.

stability · Tension field
The same sheet, twice, and a factor of ten thousand. A 3000 mm developed width of 3 mm sheet, covering 2400 mm in plan — so the legs sit at 36.9° and the fold is 300 mm deep. Flat, its second moment about its own mid-plane is 6750 mm⁴, which spans nothing. Folded, it is 67.50×10⁶ — 10000 times as much, which is exactly the depth in thicknesses squared. The material is identical, the plan cover has fallen by 20%, and the only thing that changed is where the material sits. What limits it is buckling of the leg: at this leg length the flat between the folds goes at 27 N/mm², well below the steel's 275.

Folded until it spans

A flat sheet has a second moment of area of B·t³/12 and will not span anything. Folded, the same material has B·t·h²/12, and the gain is exactly the fold depth over the thickness, squared — a ratio with no material in it and no width in it.

structures · Folded plate
The bearing is one length and the web is loaded over another. A load applied over a stiff bearing of 100 mm on the flange of a girder with a 1200 × 8 mm web. The flange bends under it and the yield lines that form spread the load along the web over 559 mm — 5.6 times the bearing, and 82% of the yield resistance is that spread rather than the bearing. The effective length is not a decision anybody made: it is what the flange's own bending stiffness against the web's own strength works out to.

The load that chooses its own length

Every other load in this collection arrives over a length somebody decided. A wheel on a crane girder does not — the flange bends under it and spreads it along the web, and how far it spreads is an output of the flange's own stiffness against the web's own strength. The effective length is 5.6 times the bearing that produced it.

stability · Patch loading
The load did not move; the section did. A lipped channel 200 by 65 mm at 2 mm thick, drawn twice on top of itself: the outline as fabricated, and the part of it still working once the plates have buckled. The web is held on both edges, so it loses its middle; the flanges are held at the web, so an unlipped one would lose its free edge. What survives is not symmetric with what was drawn, so the centroid moves 8.0 mm — and a load applied along the axis it was designed to arrives 8.0 mm off the section that has to carry it. At the 177 kN this section will take, that is 1.42 kNm of bending nobody applied.

What is left after it ripples

A thin plate that buckles locally has not failed. It has stopped taking load in its middle and gone on taking it near its edges, so the member is now made of a different section from the one that was drawn — and the new one has its centroid somewhere else, which turns a concentric load into an eccentric one.

sections · Effective cross-section
Two faces, a couple, and a core that does none of it. A sandwich section 61.4 mm deep: two 0.7 mm faces separated by 60 mm of core. The bending is carried as a couple between the faces — 41 N/mm² of tension in one and compression in the other, over a lever arm of 60.7 mm — and the core carries a shear stress of 0.047 N/mm² and nothing else. The parallel-axis term is 98.8% of the section's second moment; the faces' own bending about their own centroids is 0.004% of it, and the core's is 1.2%. Separated by nothing at all the same two faces would be 2.3e+4 times less stiff.

Two skins and the space between them

A sandwich panel is a section made of a material that carries the bending and a material that carries none of it. The parallel-axis term is not a correction here — it is 98.8 per cent of the second moment — and the shear deflection is not a correction either.

sections · Sandwich section
Not where the two loads meet. How much a column loses below the weaker of its two single-mode capacities, against the ratio of its local critical load to its global one. The received claim is that the worst place is where the two coincide; the arithmetic says otherwise. The erosion is largest at a ratio of 0.47 — 23% — sits within a per cent of that for every ratio below about a half, and at exact coincidence is only 2%. What the curve does say is the useful half of the folk claim: once the plates are stocky enough that the local critical load is twice the global one, the interaction is nothing at all, and the section is worth thickening only up to there.

Two ways of buckling at once

A thin-walled column can bow as a whole or ripple in its plates, and each has its own critical load. The received advice is that the worst arrangement is the one where the two are equal. The arithmetic says the opposite — at coincidence the interaction costs two per cent, and the expensive region is where the plates go first.

stability · Mode interaction
Pull it along the girder and it just unfolds. One period of a 30° trapezoidal corrugation, 300 mm of flat and 260 mm of incline, and the same period pulled along the girder's axis. The fold opens by bending the inclined panels out of the web's own plane, so the axial flexibility contains the plate's t³ where a flat web's would contain t — and the effective modulus that comes back from solving the cell as a frame is 222 N/mm², which is 10.6 parts in ten thousand of the steel's 210 GPa. A web with a thousandth of the stiffness carries a thousandth of the stress, which is why the flanges of a corrugated girder carry the whole moment and why the section has 9 per cent less second moment than the flat-webbed girder it replaces. The fold buys freedom from stiffeners and pays for it here.

The web that carries no bending

A corrugated web needs no stiffeners, because the folds give it in one direction a depth it does not have in its thickness. In the other direction the same folds make it an accordion — and a web that cannot be stretched cannot carry a bending stress at all.

sections · Corrugated web
Three minima, and only two of them get a check. Elastic buckling stress against half-wavelength for a 200 × 65 × 15 × 1.5 mm lipped channel in uniform compression. The local minimum is at 200 mm and 41 N/mm²; the distortional at 689 mm and 287; the global curve falls away to the right and reaches 489 at the 1.5 m member. The distortional branch is a strut on an elastic foundation — the flange and lip rotating about the web junction, restrained by the web's own bending at 627 N·mm per radian per millimetre — so its minimum is at π(EC_w/k_φ)^¼ and its value is (2√(EC_wk_φ) + GJ)/I₀, the same closed form a continuously braced strut has. The elastic stresses are in the order local, distortional, global, and the mode that governs the strength is not the lowest of them, because they have very different amounts of post-buckling reserve.

The mode between the two that get checked

A thin-walled strut has three ways of buckling and two of them have design rules. The third has a half-wavelength several times the section depth, a shape in which the fold lines themselves move, and an elastic stress that no effective-width calculation can produce.

stability · Distortional buckling
A transverse load with nothing applied. Web slenderness against web thickness, with the limit the flange's own curvature sets. A flange carrying 6213 kN and curved to a radius of 592 m needs 10.5 N per millimetre of radial force to stay on its curve, and the only thing available to supply it is the web. Nothing has been applied to the girder: the load comes from the deflected shape, which is why a straight beam has none of it and a beam at a plastic hinge has a great deal. Setting the radial force against the web's own plate-buckling resistance gives, in four lines, h_w/t_w ≤ k·(E/f_yf)·√(A_w/A_fc) — the form the codes use, arrived at without them. The constants differ: an elastic flange strain gives k = 1.34 and the rule uses 0.3, a factor of 4.5, and the gap is the curvature assumed. k goes as the inverse square root of the flange strain, so 0.3 is a flange strained to 3.4% — which is what a plastic hinge does to it. The rule is not conservative; it is written about a different beam.

The web that is crushed from inside

A plate girder's compression flange is curved by the beam's own deflection, and a curved force needs a transverse load to stay on its curve. The only thing available to supply it is the web. So a deep girder can buckle its web vertically with nothing applied to it at all, and the rule that prevents it is the only clause in the codes about a load no load case contains.

stability · Flange induced
A stiffener is a boundary condition, and it is bought at a threshold. The buckling stress of a 2400 × 12 mm plate with one longitudinal stiffener, against how rigid that stiffener is. Below γ the stiffener rides on the buckle and the plate takes the whole-width mode; at γ the stiffener stays straight and the plate buckles between stiffeners at 74 N/mm², 4.0 times the bare plate's 18.5. Above γ nothing further happens at all, because the sub-panel mode does not know the stiffener is there. The curve is a ramp and then a horizontal line, so a stiffener at twice γ is exactly as good as one at γ. Here γ = 31.5, which asks for an outstand of 144 mm; the 150 mm one drawn gives γ = 35.5, a margin of 1.13.

The rib that is a boundary condition

A rib on a plate is not a member carrying load. It is a line the buckle is not allowed to cross — and it becomes one at a threshold. Below the required rigidity it rides on the buckle and buys a fraction; at the threshold it stays straight and the plate buckles between stiffeners; above it, nothing further happens at all.

stability · Stiffener rigidity
The tube flattens because of the bending, and then cannot carry it. Moment against curvature for a long tube of radius 300 mm and wall 4 mm. Compression on one face and tension on the other are both directed along a curved line, so each produces an inward transverse pressure and the circle is squashed into an oval by the bending it is carrying. That reduces the second moment, so the curve bends over and reaches a limit point — no bifurcation, no imperfection, nothing to be sensitive to. It arrives at an ovalisation of exactly 2/9 for every tube of every size in every material, at 1018 kNm, where the secant stiffness has fallen to 67 per cent of the undeformed value and the tangent stiffness is zero. The relaxed path reproduces the closed form to 0.004 per cent.

The tube that flattens itself

Bend a tube and the compression on one face and the tension on the other are both running along a curve, so both push inward. The circle becomes an oval, the second moment falls, and the moment–curvature curve turns over at a limit point that needs no imperfection, no bifurcation and nothing to be sensitive to.

stability · Brazier buckling
The section that is checked is not the section that was chosen. A 457 mm beam coped 50 mm deep over 120 mm to frame into a girder. What is left is a tee with a section modulus of 3.836e+5 mm³ against the whole section's 1.438e+6 — 27 per cent. The moment at the end of the cope is the reaction on a lever arm of 130 mm: 23.4 kNm, giving 61 N/mm² and a flexural utilisation of 0.17. The web now has a free edge along the cope, so its buckling coefficient collapses from 4 to 0.425 — a factor of 9.4 — and the re-entrant corner has a stress concentration of 5.5 on a 10 mm radius.

The section that is checked is not the one chosen

A beam framing into a girder has its top flange cut away so the two can sit at the same level. What is left is a tee with a quarter of the section modulus, a web with a free edge, and a re-entrant corner — and the beam was selected on a table entry that describes none of it.

connections · Coped beam
The best design is where two failures arrive together. A fixed area of steel rolled into tubes of every proportion, with the three things that can end each one. Euler's load goes as r² because I = A r²/2; the local buckling stress goes as 1/r² because the wall thins as the tube grows; squashing does not care. The capacity is the lowest of the three, so it has a maximum — and the maximum is exactly where the two buckling curves cross, at r/t = 129 and 2364 kN, which the closed form r*, the fourth root of αAL² over π³β√3, reproduces to 0.52 per cent. That is the general result and it is not about tubes: the optimum of a minimum of a rising and a falling curve is always their intersection, so optimising a design against two failure modes puts both of them at the design point — which is the one configuration imperfections hurt most.

The best design is the most sensitive one

Take a fixed area of steel and roll it into a tube. Euler's load rises with the radius and local buckling falls with it, so the capacity has a maximum — and the maximum is exactly where the two failure modes arrive together, which is the one configuration imperfections hurt most.

stability · Wall optimum
The confinement that slenderness switches off. The capacity of a concrete-filled tube against slenderness, divided by the plain sum of its two materials. Below about λ̄ = 0.5 the concrete is confined and the section is worth more than its parts — up to 29 per cent for a stub. Above it the bonus is gone, because confinement needs the concrete to dilate, dilation needs strain, and a slender column buckles before it gets there. The column drawn is at λ̄ = 0.42 and has 0.3 per cent of a bonus, which is to say none. What does not switch off is the other half: at d/t = 80 an empty tube buckles locally at 286 N/mm², below its own yield of 355, and the filled one reaches 508 because the wall cannot go inward. That is worth more than the confinement ever was, and it applies at every slenderness.

Each one stops the other failing

A concrete cylinder crushes by splitting outward and a thin steel tube fails by rippling inward. Put one inside the other and each material's failure mode requires a movement the other one prevents, which is a much stronger statement than composite action.

materials · Filled tube
Block shear: the metal between the holes. Three bolts in a 9 mm plate end connection. The shaded block tears out along a shear plane 180 mm long and a tension plane 55 mm long. Shear ruptures first, and the capacity is the sum of two different strengths on two different planes: 524.79 kN, of which the shear plane carries 63.03%.

The end that is only a plate

Cut one flange off a beam's end and what is left is a tee. Cut both and what is left is a plate with holes in it — no flanges, no section modulus worth the name, and none of the checks the beam was selected by. Three plate checks replace them, and the one that governs depends on dimensions that appear in no section table.

connections · Coped beam
Each repair reaches the checks its plate touches, and no others. The four checks on a 457 mm beam coped 50 mm deep over 200 mm, carrying a reaction of 300 kN through three bolts, as utilisations, for the end as coped and with three repairs: an 8 mm doubler on the web, a 100 × 10 mm plate along the free edge, and both. As coped the utilisations are flexure 0.46, shear 0.41, tear-out 0.57 and local buckling 0.46. The doubler thickens the web, which is most of what a coped tee is, and lowers all four; the edge plate gives the tee back a flange and lowers only flexure and buckling, leaving shear and tear-out exactly where they were. What governs: as coped, tear-out at 0.57; doubler, tear-out at 0.30; edge stiffener, tear-out at 0.57; both, tear-out at 0.30.

The repair that fixes the wrong check

A coped beam end that fails its checks is usually repaired by welding a plate along the edge the cope left, because the cope removed a flange and the plate puts one back. On ordinary proportions that repair restores the check that was not failing. The check that governs is carried by the web, and only a plate on the web reaches it.

connections · Coped beam

The plate that arrives after the load

A repair plate welded to a beam already in use carries only the load that arrives after its weld has cooled. The elastic checks remember that order — a doubler welded under 60 per cent of the reaction removes 40 per cent of the stress it would remove from an unloaded beam — while tear-out, a plastic mechanism, gets the whole of the repair. Propping the beam is what hands the plate the load already there.

connections · Coped beam

Named alongside it

The objects these essays reach for when they reach for this one.

Plate bucklingSlendernessEffective widthLoad pathShear areaCritical loadNet sectionPost-bucklingSecond moment of areaStiffenerStiffnessBlock shear

All concepts