Concept

Uplift — where it appears

Tension where a structure was expected to press down, which arrives at one edge of a base long before anything is close to tipping over. It appears at one edge of a base as soon as the resultant leaves the kern, long before the overturning factor of safety is anywhere near one.

Named by 17 essays across 4 fields — each of them below, with the objects they name alongside it.

Weight is the only thing holding it down. A body 2.5 m wide and 6 m tall weighing 120 kN, under a wind pressure of 1 kN/m². The wind delivers 48 kN and an overturning moment of 144 kNm about the leeward toe; the weight restores 150 kNm, a factor of 1.04. The resultant lands 1.20 m from the centre against a middle third of ±0.42 m, so the base is lifting over 2.35 m of its width.

Weight is the only thing resisting it

A structure that is strong enough everywhere can still be blown over, and nothing in its material properties has any part in whether it is. The whole answer is a weight and a width — and the failure begins long before anything tips, at the moment one edge stops pressing down.

equilibrium · Overturning
The middle third, computed. The kern of a 400 × 600 mm rectangle, computed by asking, for every direction, how far the resultant can move before the far face would be pulled. It reaches ±100.0 mm vertically and ±66.7 mm horizontally, which are h/6 and b/6 exactly, and the region between is a rhombus rather than the ellipse the two numbers suggest — a resultant on a diagonal has less room than either axis allows.

The middle third

A material that cannot be pulled imposes a condition on where the load may land, and the condition is a region rather than a point. For a rectangle it is the famous middle third; for every other section it is a shape nobody quotes, and one ordinary section's is nearly twice as generous as the rule allows.

sections · Kern
A basement is a boat. A 20 by 30 m substructure dug 6 m into ground whose water table stands 2 m down. The head on the underside of the base slab is 4.0 m, so the pressure there is 39.2 kN/m² over the whole plan — 23.5 MN of it, pushing upward. Nothing about the structure changes that number. What resists it is weight: 18.7 MN of concrete and whatever is built above, giving a factor of 0.80. The structure floats if the water reaches 2.82 m below the ground, and a base slab alone would have to be 1.64 m thick to hold it down.

A basement is a boat

Every load in this collection presses down and is resisted by strength. Hydrostatic uplift presses up, is resisted by weight, and does not care what is built on it — so the check contains no material property at all. It is a ratio of two weights, and one of them is water.

equilibrium · Uplift
Held up by a pressure nobody can feel. An air-supported roof of 60 m span and 9 m rise. The membrane has no bending stiffness whatever, so the only thing that can hold it in tension is a pressure difference, and the pressure has to exceed the load per unit plan area and nothing else: 0.25 kN/m² of fabric plus 0.6 of snow is 0.85 kN/m², so 1.19 kN/m² does it — 1190 pascals, which is 1.17 per cent of an atmosphere and 121 millimetres of water. Ears do not notice it. A door does: at 2.1 kN on an ordinary leaf, the building needs an airlock rather than a handle. And the whole of it arrives at the foundation as 3365 kN of uplift — 17.9 kN on every metre of perimeter — which is the bill the pressure's smallness conceals.

Held up by the air inside

A membrane has no bending stiffness at all, so the only thing that can hold it in tension is a pressure difference. The pressure needed to hold up a roof is smaller than the pressure a closed door makes — and the same pressure arrives at the foundation as hundreds of tonnes of uplift.

structures · Pneumatic structure
The wind pushes on one face and pulls on three. A 30 × 20 m building in plan, with the measured pressure coefficient on each face and the arrows drawn in the direction the pressure acts. Only the windward face is pushed; the other three are sucked, and the side faces are sucked hardest of all at c_p = -0.7. The horizontal resultant is 842 kN at a velocity pressure of 0.9 kPa, and the arithmetic of it is the whole point: the leeward suction pulls the building downwind, so it ADDS, supplying 38% of the answer, while the two side faces cancel each other exactly and supply none of it. The coefficients are wind tunnel data; what is computed is the free body they are applied to.

Most of it is suction

A wind load is drawn as arrows pressing on the windward face, which is where about three fifths of it comes from. The rest is a pull on the back. The two side faces carry the largest suctions on the building and contribute nothing at all to the answer — and the inside of the building, which nobody draws, decides whether the roof stays on.

equilibrium · Wind pressure
The group is not weaker; it is very much softer. A 3 × 3 pile cap on the left, with each pile's share of 9.0 MN and 4.5 MNm in meganewtons — N/n plus M·y/Σy², the same three terms in the same order as a bolt group under an eccentric load and a section under biaxial bending. The corner piles take 1.25 times the average and a pile added at the centroid would change that by nothing at all, because it adds to neither second moment. On the right is the effect a bolt group cannot have: the piles share ground, so the stress bulbs overlap and the group settles 3.9 times as much as a single pile at the same load per pile, rising to 14.2 for 144 of them. The capacity check everyone makes — block failure against the sum of the piles — comes out at 4.54 here and does not govern at all. The check nobody tabulates is the one that does.

Nine piles, and four times the settlement

A pile cap divides its load between its piles by the same three terms a bolt group uses and a section under biaxial bending uses. What a bolt group does not have is neighbours it shares ground with — and the group effect that matters is not the strength check everybody makes, but a stiffness effect nobody tabulates.

structures · Pile group
Every pressure points at the pin, so the water lifts nothing. A radial gate of radius 8 m holding 6 m of water, with its pivot 6 m above the sill. The pressure on a curved surface cannot be obtained by multiplying anything by anything, so it is integrated round the arc: the horizontal component comes to 176.6 kN/m and the vertical to 110.5. Both are recoverable without any integral at all — the horizontal is the pressure force on the surface's own vertical projection, γH²/2 = 176.6, and the vertical is the weight of the water standing above it, 110.5. They agree to 0.000 per cent. And because every pressure is normal to a circle, every one of them passes through the centre: the moment of the whole 208 kN/m about the pivot is -3.4e-15 kNm, against 353 for a flat gate on the same hinge.

Every pressure points at the pin

Pressure acts normal to a surface, so on a curved one every element pushes in a different direction and no multiplication gives the resultant. Two free bodies recover it without an integral — and on a circular surface a third observation makes the whole force disappear from the equation a hoist has to satisfy.

equilibrium · Curved surface pressure
The push that tips it, in every direction. The tipping push in each plan direction, drawn as a distance from the centre, for a 6000 kN body with its weight 15 m up and the push at 18 m. On rigid ground the curve is the hull's: weakest along the axes at 1333 kN. On four equal pads it shrinks, and more toward the corners. With the pads as built — stiffnesses 20000, 20000, 8000, 20000 kN/m — it is no longer symmetric: the weakest direction is 15°, on the soft pad's side, at 1039 kN.

It tips inside its own hull

On rigid ground a body tips when its resultant reaches the edge of its base, and how stiff its supports are has nothing to do with it. On pads that settle, the body leans as it is pushed, the lean moves its weight, and the push that tips it falls by one number a site engineer already has: settlement times the height of the weight, over the square of the half-width. Toward a corner the loss doubles, and one soft pad makes the weakest direction one nobody checks.

equilibrium · Overturning
Closer piles add pull-out the block cannot pay for. For 600 mm piles 15 m long under a 20 × 30 m raft, in ground whose shaft friction is 0.30 of the effective vertical stress and whose submerged unit weight is 10 kN/m³: the summed pull-out of every pile on a square grid (thin, rising steeply as the spacing closes), the submerged weight of the block of ground the group would lift (dashed, 90 MN whatever the spacing), and the group's capacity, the lesser (solid). The two meet at 2.06 m — 3.4 pile diameters — where s² = π·d·β·L/2. Closer than that the group lifts the block and the extra piles add nothing; the most piles worth having is about 142.

The piles that would lift the ground

A basement too light to stay down can be pinned down with tension piles, each holding by the friction on its shaft. Add enough of them, close enough together, and the ground between them stops being something they grip and becomes something they carry: the group lifts out as a block, and the block's weight is all it can hold. For 600 mm piles 15 m long that happens closer than 2.06 m apart, a spacing with no raft, no water and no load in it — and every pile past that point is paid for twice.

equilibrium · Uplift
How long the pumps must run is set by how fast the water comes back. The floors that must be cast before the pumps stop under a 20 × 30 m basement dug 6 m below a water table at the surface, its 0.9 m slab and walls weighing 18.7 MN against 35.3 MN of uplift when the water is back, so that the weight stays ahead of the water at every instant, against the water's recovery time on a logarithmic scale, for a floor every 5, 7 and 10 days. If the water returns at once, five floors — the building has to be nearly heavy enough on its own. With a floor every 5 days: 3 at a 3-day recovery, 2 at 7, 0 at 14; a floor every 7 days: 4 at a 3-day recovery, 3 at 7, 1 at 14; a floor every 10 days: 4 at a 3-day recovery, 3 at 7, 2 at 14. Dashed, the closed form for weight added continuously at a floor a week, which runs about one floor below the steps: a floor arrives at the end of its cycle, not through it.

The water that comes back while the floors go up

A basement below the water table is built dry, inside an excavation kept pumped, and the building that will one day hold it down is not there yet. When the pumps stop, the water comes back over days and the frame goes up a floor a week, and the basement is safe only if the weight stays ahead of the water at every instant. How long the pumps must run is not set by how heavy the building is. It is set by one ratio — how much weight the frame adds while the ground refills — and for a basement that needs five floors on it to hold itself down, a seven-day recovery asks for three and a fourteen-day one for one.

equilibrium · Uplift
The linear answer has the ground holding the ends down. The contact pressure along a strip 16 m long, EI 5.40 × 10⁵ kN·m², on a bed of 50 × 10³ kN/m² per metre of its length, under a column of 1,000 kN. With springs that pull as readily as they push (dashed) the bed presses 197 kN/m under the column and pulls down on the ends at up to 34 kN/m — tension the ground cannot supply. With the pulling springs released (solid), the strip touches the ground only from 3.97 m to 12.03 m, 8.05 m in all, and presses 213 kN/m under the column, 8 per cent more; beyond that it carries nothing.

The ends the ground was holding down

Winkler's springs pull as readily as they push, and on a long footing strip the linear answer quietly uses that: it has the ground holding the strip's ends down. Take the pull away and the correction under the column is modest — eight or nine per cent on the pressure and the moment — but the shape of the answer changes completely. A weightless strip longer than about eight metres keeps exactly eight metres of itself on the ground, whatever length was poured, and the rest rises off as straight cantilevers carrying nothing. The middle-third rule turns out to be a property of rigid footings: an eight-metre strip lifts at a fiftieth of the eccentricity the kern allows.

internal-forces · Elastic foundation
The water that rises after the basement is finished pushes on its slab first. Section through a line of columns of a 20 × 30 m basement dug 9 m, its 0.9 m slab held down at six columns and by 8 storeys above, designed for a water table 3 m below the ground. The water table as designed is 3 m below the ground, a 6 m head under the slab; dashed, the same water risen 1.0 m. The slab bows up between its columns and walls under the uplift less its own weight (exaggerated). As designed, the building holds itself down at 0.65 of its weight's capacity, the slab is at 0.37 of its bending strength and its cracks are 0.140 mm against the 0.200 mm long set for every crack in concrete that must keep water out. With the water 1.0 m higher: 0.76, 0.45, and 0.176 mm against the same 0.200.

The basement that leaks before it floats

A water table that rises after a basement is finished is a load that grows through the building's life, and the building's flotation check is the last thing it troubles. A metre of rise adds a sixth to the uplift on the whole building but over a quarter to the net load on the slab, which carries the water less its own weight. The slab's cracks, which a watertight basement is designed to, are the first thing to run out of room — and the limit for the cracks that pass right through it tightens as the water rises.

equilibrium · Uplift
Ground already loaded rocks stiffer than springs that are not. The moment on the column against its rotation through a storm that takes the moment to ±1,000 kN·m and back, for an 8 m strip of EI 540 MN·m² on a bed of 50 MN/m² under a 1,000 kN column: on elastic springs that cannot pull, and on ground that unloads and reloads 4 times as stiffly as it first loads, in the first storm and the third. On elastic springs the column turns 1.418 milliradians at the peak, a rocking stiffness of 0.70 GN·m/rad, the same every storm. On the remembering ground it turns 1.116 in the first storm and 0.868 in the third — 0.90 and 1.15 GN·m/rad — because rocking unloads half the strip, and ground that has carried the column unloads stiffly.

The footing the storms press down

A footing strip under a column that a storm rocks one way and then the other was expected to dig itself a bowl: its ends loaded half the time, compacted, and left hanging over the hollow. On ground that unloads and reloads four times as stiffly as it first loads, the bowl appears and the strip fills it. The column settles 26% more over three storms and then stops; the footing rocks 22% less than it did in its first storm and is 64% stiffer than on springs that forget, because rocking unloads half the strip and ground that has carried the column unloads stiffly. The storms change the settlement and the stiffness, and leave the moments almost where they were.

internal-forces · Elastic foundation
Under a light building the first thing the pump was holding up is the building. The hours after the pump stops at which each check on the basement is used up — the slab's 0.2 mm cracks and the building's flotation — against the number of storeys over it, with the water table risen 3.0 m and ground recovering in 12 hours; drawn at 48 hours where a check is never used up. The cracks' deadline is 9.5 h whatever the building. Flotation's is at once under 2 storeys, 1.0 h under 4 storeys, 4.7 h under 5 storeys, 10.1 h under 6 storeys, never under 8 storeys; with 5 storeys or fewer it comes first.

The building held down by its pump

A basement whose water table has risen above its design level is often given back its design head by a pump under the slab, and from then on it is safe while the pump runs. When the pump stops the water comes back on the ground's own clock, and the checks the pump was protecting are lost in an order the building's weight decides. Under eight storeys only the slab's cracks were ever at risk; under five, the building's flotation check goes first, four and three-quarter hours after the pump stops, and the slab's strength is never in question at all. A structure that was safe by its weight has become one that is safe by a machine, and the machine's reliability is now one of its loads.

equilibrium · Uplift
The silt hands the head back over decades, a season at a time. The basement is under five storeys, its water table 2.0 m above the design head and swinging ±0.5 m over the year, highest in April; pumped drains under its slab start 30 times as conductive as the ground. The head under the slab above the design head, against the years since the drains were new, for drains silting with time constants of 4, 8 and 16 years; dots, a standpipe read every October on the 8-year drains. With those drains the head reaches flotation in the wet season of year 24.1; the reading first exceeds 0.25 m in year 14.8, 9.4 years before.

The drain that fails a season at a time

A basement held at its design head by drains and a pump can fail suddenly, when the pump stops, or slowly, when fines settle in the drains and the head under the slab creeps up while the pump keeps running. The slow failure gives a standpipe read once a year a decade of warning, in its own time constants — if it is read in the wet season. And long before the silt floats the building on its own, it has made every stop of the pump more likely to.

equilibrium · Uplift
How large an opening it takes to lift the roof. The uplift on a 600 m² roof against the area of one opening in the windward wall, with the whole of the rest leaking 3.00 m². With leakage alone it is 31 kN against a roof weighing 360 kN. The uplift passes the weight at 1.8 m². At 4.8 m² it is 593 kN.

The pressure the openings decide

A building's internal pressure is usually read from a table with three or four rows in it. It is really a balance: the air inside stays at whatever pressure lets as much out as comes in, and that makes it a statics problem with one unknown. Solved, it says a window of 1.8 m² in a 720 m² wall is enough to lift a 360 kN roof. It says the wall between two rooms carries more wind than the wall outside it. And it says the air in the room is a mass on a spring, which overshoots when the window breaks.

equilibrium · Wind pressure
The head under the slab when the drains are cleaned. The head under the slab above its design head over 120 years, the drains silting with a time constant of 8 years: never cleaned, reaching flotation at 0.97 m in year 24.1; cleaned every 4 years with 20% of the silting beyond reach, year 104.2; and with half of it beyond reach, year 44.2.

The silt a jet cannot reach

A basement held down by drains that silt up floats in the spring of year 24 if nobody touches them. Clean them every four years and it floats in year 104 — if a fifth of the silting is in places no jet reaches; in year 44 if half is. The cleaning interval barely matters beside that share, and the share is not knowable when the drains are laid. But it is measurable as soon as they are first cleaned: the standpipe read just after a cleaning sees only the silt that stayed, and its trend is the drains' life.

equilibrium · Uplift

Named alongside it

The objects these essays reach for when they reach for this one.

Free bodyEquilibriumHydrostatic pressureFlotationOverturningBearing pressureDrainageEccentricityElastic foundationFactor of safetyKernLoad path