Concept

Sway stability — where it appears

A frame's resistance to lateral displacement under vertical load, measured by how far its critical load exceeds the applied one. A frame that sways carries its gravity load sideways, so its moments are amplified and the amplification grows without bound as the critical load is approached.

Named by 6 essays across 2 fields — each of them below, with the objects they name alongside it.

The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached.

The load that is really a lean

No frame is ever plumb. The columns are out of upright by something like a three-hundredth, and every tonne of gravity load standing on that lean has a horizontal component. The force that represents it is not a safety allowance — it is an exact statics substitution for a geometry nobody drew.

equilibrium · Notional load
The load being amplified is not the load doing the amplifying. The sway amplifier 1/(1 − ΣP/P_cr) against the storey's total gravity load, as columns are added that carry load and provide no lateral stiffness. The critical load of the storey is fixed at 8203 kN by the bracing that exists, and every leaning column moves the structure along the axis without changing it. At the storey drawn the amplifier is 1.57, so the second-order sway moment is 57% on top of the first-order one — and none of that 70% of the load which is causing it appears in any stability calculation done column by column. The storey stays stable across the whole of this axis. That is the practical reason a gravity-only column is drawn on the frame model rather than designed on its own: it is not being checked, it is being counted.

Counted, not checked

A column with pinned ends and no bracing cannot buckle on its own, so nothing about it fails a stability check. It still carries load, and load with no stiffness attached lowers the buckling load of everything around it — which is why a gravity-only column is put on the frame model and never designed by itself.

stability · Second-order
A base plate, and when the bolts start working. A 550 × 450 mm plate carrying 900 kN and 140 kN·m, so the resultant sits 155.56 mm from the centre against a kern of 91.67 mm. The plate is in partial contact: bearing over 358.33 mm at a peak of 11.16 N/mm², with the holding-down bolts carrying 0 kN. The plate lifts at 82.5 kN·m and crushes at 192.95 kN·m, and the bolts are not needed until 247.5 kN·m.

The pinned base that is not pinned

A column base drawn as a pin is a plate bearing on grout, and a plate in contact over its whole length resists rotation whether anybody wanted it to or not. The stiffness it delivers depends on the axial load, so the assumption is one a frame can leave and re-enter as its loads change.

stability · Sway stability
Wrong in both directions until the building racks. Across buildings from a pure bending tower to a pure racking frame (αH on a logarithmic scale), each 20 storeys with gravity putting its own critical factor at 5.0: solid, the least storey sway factor over the building's own, which is what taking the least storey as the building's costs; dashed, the ground storey's second-order increase estimated from its own sway factor, over the true increase. At αH = 0.1 the least storey factor is 0.77 of the true one and the ground storey's estimate 0.09 of the true increase; at αH = 10, 0.86 and 0.37; at αH = 100, 0.94 and 0.98. The first error is on the safe side and the second is not, and both vanish only for a building that racks.

The storey that cannot see the building lean

A sway check made storey by storey asks each storey how much it drifts under a push and how much gravity sits on it, and reads a critical load factor for the storey from the two. For a frame whose storeys rack like a stack of shelves that is exact. For a building that bends — a braced core, a wall — it is wrong twice. Taking the least storey as the building's reads a critical factor of 3.9 for a building whose own is 5. And amplifying each storey by its own factor finds a 2 per cent second-order increase at the ground storey, where the truth is 20, because the ground storey hardly drifts and carries the lean of everything above it.

stability · Sway stability
The buckling mode moves up to where the spine is not. The building's first buckling mode, each floor's sideways movement as a fraction of the roof's, up the height of a 20-storey building of a bending spine and a racking frame (αH 1.0), its gravity scaled to an elastic critical factor of 5.0, under an equal lateral load at every floor: the spine to the roof, and stopping at storeys 15 and 10. With the spine to the roof the mode is the bending tower's, growing all the way up. With the spine stopping, at storey 15 its top moves less than a thousandth as far as the roof, and at storey 10 its top moves less than a thousandth as far as the roof: the building buckles in the first storey of frame above the spine, every floor above that storey moving with it as one, and the spine takes no part.

The storey above the core decides

A building whose bending core runs to the roof shares one sway mode between its core and its frame, and the storey-by-storey stability check reads it wrongly twice. Stop the core five storeys short and the check becomes exact: the first storey of bare frame above the core reads the building's own critical factor to three figures, because the whole building buckles there and nowhere else. The check stays wrong below the core, and it goes wrong again when the frame above is more than about twice as stiff.

stability · Sway stability
A hat makes the top storeys look stiff. Each storey's own sway factor α up the height of a 20-storey building of a core to the roof and a racking frame (αH 1.0), its gravity scaled to an elastic critical factor of 5.0, under an equal lateral load at every floor: with no hat, with a hat truss at the roof holding the core's rotation with 10 times the core's EI/H, and with the same restraint at storey 10; the building's critical factor 5.0 as a vertical line. With no hat the top storeys read the least, 4.06 at the roof. With the hat the roof storey reads 15.47 and the least, 4.14, has moved down to storey 9. With the outrigger at mid-height the least is back at the top, 3.85.

The hat that hides the lean

A hat truss on a core-and-frame building holds the top of the core, nearly doubles the building's critical load, and makes its top storeys look three or four times as stiff as they did. The storey check believes them. Under the hat the roof storey reads a sway factor of 15 and estimates 7 per cent of second-order drift; the building still buckles leaning, and the roof storey's true increase is 24 per cent. The hat turns the storey check from pessimistic to unsafe at exactly the storeys it was built to stiffen.

stability · Sway stability

Named alongside it

The objects these essays reach for when they reach for this one.

P-deltaAmplification factorBuckling modeCritical loadFree bodyLateral systemSecond-orderStorey driftBracingCritical load factorEccentricityEffective length

All concepts