Concept

Splitting — where it appears

A tension acting across a compression that is spreading, which appears wherever a force is delivered to something wider than itself. It has no external load behind it, it is invisible to any equilibrium check on the member as a whole, and it is what cracks anchorage zones and concrete cover.

Named by 4 essays across 2 fields — each of them below, with the objects they name alongside it.

The force spreads, and the spreading needs a tie. The end block behind an anchorage of 1200 kN on a 200 mm plate, in a section 700 mm deep. Half the force enters at the quarter point of the plate and leaves at the quarter point of the section, so a strut between the two rises 125 mm and needs a transverse tie to turn it. Placing the tie 0.5 depths from the face makes that tie force 214 kN — and at exactly half a depth this reproduces Guyon's 0.25P(1 − a/h) to the digit, which makes that famous coefficient a lever arm somebody chose rather than a property of concrete. The bearing stress under the plate is 20.0 N/mm² against 5.7 once the force has spread.

The force that splits what it pushes on

A prestressing tendon delivers its whole force through a plate a fraction of the section deep. One depth further along the stress is uniform, and the spreading in between requires a transverse tension nobody applied — the force that splits end blocks, and the only number in the design that no equilibrium equation on the member can see.

internal-forces · Anchorage zone
Cover enters twice, and the strength of the concrete enters once. How long a 20 mm bar has before the cover over it splits, against the cover, split into the two halves it is always split into. Initiation is the time for the chloride front to reach the bar, which goes as the square of the cover — Fick's law and nothing else — and it is 9.1 years at 35 mm and 36.2 at 70. Propagation is the time from there to a split cover, which is short: 0.9 years, because the cover cracks at a section loss of 0.21% and no strength check in this collection would notice a loss that small. The pressure the cover can take grows with the cover too, so cover appears in both terms and the concrete's own tensile strength appears in one of them, linearly. That asymmetry is why every durability clause in every code is about cover and crack width, and hardly at all about strength.

The load that comes from inside

Every action in this collection has been applied from outside — a weight, a pressure, a movement, a temperature. Corrosion is not applied at all, and the reason it belongs to statics rather than to durability is that what does the damage is a load: rust occupies three times the volume of the steel it came from, and the only place to make room is by pushing the cover apart.

materials · Corrosion
An enhanced strength that is the strength of a tie. Bearing strength as a multiple of the design cylinder strength, against how far the load is allowed to spread, with the bursting tension the spread creates on the same axis. The enhancement is √(A₂/A₁) and it reaches 2.80 for the 250 mm pad on a 700 mm block drawn — 47.6 N/mm² against a design strength of 17.0. There is no material property in that statement beyond the one being enhanced, and the reason is on the second curve: a load that spreads does so along inclined struts, a pair of inclined struts has a horizontal component, and that component is 16.1% of the load. It has to be tied. 1099 mm² of steel is what the enhancement actually is, and the cap of three is not a property of concrete — it is the angle past which nobody believes the strut.

Three times as strong under a smaller pad

Press a small plate onto a large block of concrete and it will carry three times the stress a cylinder of the same concrete fails at. The enhancement is a ratio of areas with no material property in it, which should be a warning: what has actually been measured is not the concrete's strength but the strength of a tie holding it together.

internal-forces · Bearing stress
The strength that does not keep pace. Concrete's mean tensile strength against its characteristic compressive strength, with the ratio of the two on the same axis, scaled. The tensile strength goes as f_ck^⅔, so it rises from 1.57 to 5.04 N/mm² over a sixfold rise in the compressive strength, and the ratio between them falls from 11.1% at C20 to 6.0% at C80 — a factor of 1.83. Nothing in a bending or a column calculation ever uses the lower curve, and everything that decides a transition does: when the section cracks, how much minimum steel it needs, how far a bar has to be lapped, what a member without links carries. So a stronger concrete needs more minimum reinforcement, longer laps and a bigger crack-control check, in a member whose ultimate capacity has barely moved. Its real scale is a length: E·G_F/f_ct² is 299 mm here, which is the size at which a member stops behaving plastically and starts behaving like a fracture problem.

The strength that is never used

Concrete's tensile strength appears in no bending calculation, no column calculation and no shear calculation with links in it. The whole design philosophy is that it cracks and the steel takes over. And it decides where nearly every transition in the subject sits — when a section cracks, how much minimum steel it needs, how far a bar has to be lapped, what a member without links can carry, and how wide a crack opens.

materials · Tensile strength

Named alongside it

The objects these essays reach for when they reach for this one.

AnchorageAnchorage zoneBearing stressBondBurstingCrack widthFree bodyLower-bound theoremPrestressReinforcementStress trajectoryStrut-and-tie

All concepts