Concept

Moment connection — where it appears

A joint detailed to carry bending across a gap between members, by putting a force couple across whatever separation the section offers. Its lever arm is the distance between its tension and compression components, which makes the depth of the connection the design variable.

Named by 7 essays across 3 fields — each of them below, with the objects they name alongside it.

A portal frame swaying under 20 kN. A portal frame pushed sideways, solved by the stiffness method because statics cannot divide the load between two columns. The base shears come out at 10.0 and 10.0 and add to the applied 20; the peak moment is 22.2. The sway is drawn hugely exaggerated, and the moment diagram is plotted on each member's tension face.

The frame that leans, and what stops it

A rectangle of pinned bars folds flat. Make the corners rigid instead of adding a diagonal and it does not — which buys an unobstructed opening and costs bending in every member of it.

structures · Portal frame
The joints are not pins, and this is what that costs. A 4-panel Pratt truss solved twice on the same stiffness matrix: once with a moment release at every member end, which is the pin-jointed idealisation, and once with the joints continuous, which is what welding them produces. The axial forces are the same to within a per cent; the bending the second solution adds is worst in member 0, where the bending stress reaches 24.3% of the axial stress. Members are shaded by that ratio.

The joint that is not a pin

Every truss drawn as a line diagram is analysed as though its joints were frictionless pins. Almost none are. The bending that follows is called secondary, which is a claim about size — and the claim is checkable.

structures · Truss
How a moment crosses a gap. A moment end plate with three bolt rows. The moment is carried as a couple: tension in the rows, compression through bearing at the bottom flange. The plastic distribution reaches 172.8 kN·m and the elastic one 142.29 kN·m, a factor of 1.21 — and the compression at the bottom flange is 540 kN either way, which is the check that gets forgotten because it is not a bolt.

Making a moment cross a gap

A moment is not a thing that can be handed across a joint. It has to be turned into a pair of forces, carried separately, and reassembled — and the whole design is a question of how the tension is shared between bolt rows that are not equally able to take it.

connections · Moment connection
The moment does not stop at the end of the beam. A portal frame of 8 m by 4 m with fixed bases, carrying 20 kN/m on the beam. The bending moment is drawn on the tension side of every member, and it runs round the corner without a break: 65.2 kNm arrives at the end of the beam and 65.2 kNm leaves down the column, which is the same number, since joint rotational equilibrium is one of the equations the frame solve satisfied. Midspan carries 94.8 kNm, and the two add to 160.0 — the 160.0 kNm of a simply supported span, to 0.0e+0 kNm. The corner takes 61% of the wL²/12 a fully built-in beam would have carried, because the columns are springs rather than walls: the beam-to-column stiffness ratio is 1.27. The beam's moment crosses zero 0.92 m from the corner and the column's 1.33 m above its base.

The moment that goes round the corner

At a rigid knee the bending moment does not stop at the end of the beam. It turns and runs down the column, and in the same instant the beam's shear becomes the column's axial force — while the block of steel that has to carry the turn appears on no member diagram anywhere.

internal-forces · Corner moment
The shear goes round the corner instead of across it. A 6-panel Vierendeel girder, 12 m by 1500 mm, under 100 kN at mid-span. There is no diagonal in it, so each panel's 50 kN of shear is carried as bending in the chords: the curves drawn along them are the chord moments, and every one passes through zero at the middle of its own panel. The local moment is the panel shear times the panel length over four, 25.0 kNm, and it adds to an axial force of 200 kN from the global moment at the same point. The girder deflects 6.20 mm against 3.18 mm for the same members triangulated — 1.95 times — and 68% of that movement is chord bending that a diagonal would have removed entirely.

The truss with no diagonals

A rectangle without a diagonal is a mechanism, so a Vierendeel girder makes its corners rigid instead. The shear a diagonal would have carried as axial force now travels as bending in the chords, and bending is a far more expensive way to move a force.

structures · Vierendeel
Prying against flange thickness. The ratio of bolt force to applied force, for a tee stub carrying 140 kN per bolt, as the flange thickness varies. Prying disappears above 31.91 mm and the flange has become a mechanism below 22.75 mm, where the shaded region begins and the bolt has stopped being the thing that decides.

The thickness that decides who fails

A bolt in a tee stub carries more than the load applied to it, because the flange bends and levers against its own edge. How much more, and whether the bolt or the flange is the thing that gives way, are both decided by one dimension — and the two regimes it separates fail in completely different ways.

connections · Prying
Two collapses for the same plate, and only one of them fits. The same three bolt rows at 90 mm pitch, folding two ways. On the left each row folds on its own pattern — 249 mm of hinge line round each bolt — and the patterns overlap, because 249 mm of fold cannot fit in a 90 mm pitch. On the right the plate does what it can actually do: the hinges run straight from one row to the next, and the whole group folds on 429 mm rather than 746. The arithmetic follows the drawing — 377 kN for the group against 657 for the rows added up.

The rows have to share one fold

Each bolt row of an end plate is checked on its own, and the answers are added up. Two rows ninety millimetres apart cannot each fold the plate on a pattern two hundred and fifty millimetres long, because there is only one plate — so the group folds on one shorter pattern, and the sum was never available.

connections · Prying

Named alongside it

The objects these essays reach for when they reach for this one.

End plateJoint rigidityPryingStiffnessBolt tensionComponent methodDuctilityFree bodyJoint stiffnessLever armPortal frameSecondary bending

All concepts