Leaning column — where it appears
Named by 2 essays across one field — each of them below, with the objects they name alongside it.
The column that leans on its neighbours
A column with a pinned base and a pinned top has no lateral stiffness at all and cannot stand up alone, and yet thousands of them do. What holds them is the rest of the storey, and what it costs is paid by whichever columns do have stiffness — whose effective length rises as the square root of the load being leaned on them, straight off the end of every chart.
The floor the columns lean on
A storey of pin-ended columns, every one a little out of plumb, leans on its floor, and the floor leans on a core. Count the floor as rigid and the core needs the sum of the columns' demands. A floor that shears in its own plane is a brace in series with the core, and the far columns lean on it before their push arrives. With a floor a hundred times stiffer per bay than a column's own sway softening, the storey's buckling factor falls from 4.0 to 1.5 and the core is asked for twice as much.
Named alongside it
The objects these essays reach for when they reach for this one.
BracingCritical loadEffective lengthStiffnessBucklingDiaphragmFree bodyGeometric stiffnessImperfectionLateral restraintLateral systemLoad sharing