The point a loaded bolt or weld group actually rotates about, which is not its centroid when the load is inclined or eccentric. Locating it gives more capacity from the same fasteners than the elastic method, at the cost of an iteration.

Named by 7 essays across 3 fields — each of them below, with the objects they name alongside it.

A bolt group under an eccentric load. A 3 by 2 bolt group carrying 100 kN at 150 mm from its centroid, with the resultant force on each bolt drawn to scale, by the elastic vector method. The load is shared equally and the torque is not, so the worst bolt carries 50.37 kN against 16.67 kN of direct shear alone — 3.02 times as much.

The bolt that carries more than its share

Six bolts, one hundred kilonewtons, and a worst bolt carrying fifty. The load is shared equally and the torque is not, and the second one is invisible on any drawing where the connection is a point.

connections · Bolt group
Two centres, and the distance between them is a torque. A storey 30 by 18 m with its walls drawn heavy, pushed in one direction by 1000 kN. The force acts through the centre of mass and the storey turns about the centre of rigidity — the stiffness-weighted centroid of the walls, at x = 15.0 m — and the distance between the two is an eccentricity of 0.00 m before the 5% that has to be assumed anyway. The table below the plan splits each wall's force into its direct share and its torsional one. Torsion relieves the walls near the centre of rigidity and loads the far ones, so the wall in trouble is not the wall carrying the most: west wall is asked for 8% more than its direct share, and the walls at right angles to the push carry 19 kN each with nothing applied along them at all.

The corner that moves most

A lateral force is shared out in proportion to stiffness only if it passes through the centre of rigidity, which is not the centre of the plan and not the centre of mass. The distance between the two is a torque, and the wall that pays for it is the one furthest away and carrying least.

structures · Plan torsion
The point the rafter turns about, which is off the frame. A pitched portal of 8 m span and 4.0 m to the eaves, with a 1.5 m rise, collapsing. Each rigid part of the mechanism rotates about some point: the left column about its base hinge, the right about its own. The rafter between them does neither, and its centre is found by one rule — two bodies joined at a hinge share that hinge, so the second body's centre lies on the line through the first body's centre and the hinge, extended. Two hinges give two lines and they cross at (8.0, 11.0) metres, which is 5.5 m above the ridge and outside any drawing of the frame itself. From there the whole collapse is two ratios of lengths and no trigonometry: the load factor is 1.339. Flatten the roof and the centre descends; make the two lines parallel and it goes to infinity, which is the statement that the rafter translates instead of turning.

The point the mechanism turns about

A collapsing frame is a chain of rigid pieces, and every piece is rotating about some point. Find those points and the whole collapse load reads off two ratios of lengths, with no trigonometry anywhere — and for a pitched roof the point in question is well above the top of the drawing.

equilibrium · Instantaneous centre
Throat stress round a fillet weld group. A l shape weld group carrying 150 kN at 200 mm from its centroid. The peak throat stress is 2.17 kN per mm of throat, at (139.53, 100); the worst point at maximum radius from the centroid carries 1.99. Checking by radius is wrong here by 9.17%, and points at identical radius differ by a factor of 1.

The radius rule, and where it fails

A weld group under an eccentric load is checked at the point furthest from its centroid, on the reasoning that the stress from the twist grows with the radius. That reasoning ignores the direction the two stresses point in, and for one common shape it misses the peak by nine per cent.

connections · Weld group
Both checks pass, and the contact lets go. A contact pressed together by 1000, with μ = 0.4. Every tangential force the contact can supply lies inside a disc of radius μN = 400.0, because the friction law bounds the length of the force and not its components. The contact is asked for 300.0 one way and 300.0 the other way — 75% and 75% of the radius taken one at a time — and 424.3 together, 106% of it. Each one-direction check passes and the force does not fit: the square those checks describe reaches √2 times further at its corners than the contact can.

Seventy-five per cent each way

A contact asked for friction in two directions at once can supply a force of a certain length pointing any way it likes, so its limit is a disc and not a square. Two checks made one direction at a time, each passing at seventy-five per cent, describe a contact that has already let go.

equilibrium · Friction
The two methods, direction by direction. Capacity against the direction of the load for three rows of two bolts of 100 kN each, loaded through (150, 150) mm. The elastic method bottoms out at 135.8 kN at 138°; the instantaneous centre at 168.3 kN at 136°, 23.9 per cent higher. Both spike to 600.0 kN where the load aims at the centroid and every bolt carries an equal share. The gap between the curves is not constant: it is widest where the elastic distribution is most uneven, which is the same place the group is weakest.

The better method flatters the worse layout

The instantaneous centre method finds capacity the elastic method cannot see, and how much it finds depends on the layout it is applied to. On a six-bolt rectangle under a load of unknown direction it is worth 24 per cent; on a ring of six with a smaller polar moment it is worth 14. The two methods agree on which layout to choose and disagree by a factor of five about the margin — and the reason is that a layout the elastic method already likes is one with nothing left to redistribute.

connections · Bolt group
What each missing bolt costs. The weakest-direction capacity of six bolts at 75 by 75 mm, loaded through a point (150, 150) mm from the centroid, with the whole group and with each bolt in turn left out. The full group carries 135.8 kN. Leaving out bolt 3 leaves 90.2 kN, a loss of 34 per cent; leaving out bolt 2 leaves 131.1 kN, a loss of 4. One sixth of the bolts is not one sixth of the capacity, and which sixth it is matters by a factor of 10. The dashed line is the capacity a group that lost a proportional share would have, 113.2 kN.

The bolt that was never fitted

A six-bolt bracket found with five bolts in it has lost a sixth of its fasteners and between four and thirty-four per cent of its capacity, depending which one is missing. The share is the smallest of the three things that changed: the centroid moves away from the gap, which lengthens the load's own lever arm, and the polar moment falls by more than the count does. The bolt whose absence costs most is not the bolt that governed the check.

connections · Bolt group

Named alongside it

The objects these essays reach for when they reach for this one.

EccentricityBolt groupElastic methodFree bodyPlastic redistributionEquilibriumLoad directionPolar momentPolar second momentTorsionAccidental eccentricityBearing