Brace — where it appears
Named by 6 essays across 3 fields — each of them below, with the objects they name alongside it.
The width nobody drew
Every other member in this collection arrives with a cross-section. A gusset plate does not — it is a piece of steel with a brace bolted to it somewhere in the middle, and no geometry says how much of it is working. The profession's answer is a thirty-degree spread from a 1952 master's thesis, it invents three quarters of the area being checked, and the check it was written for is not the one that governs.
The brace that yields both ways
An ordinary diagonal yields in tension at its full strength and buckles in compression at half of it, and the buckle leaves a hinge that does not straighten. Stop it buckling with a sleeve that carries no load at all and the loop becomes symmetric.
Twice the moment, four times the brace
A lateral brace has to be on the right flange and its demand is very nearly linear in the load. A torsional brace has no flange to be wrong about, and its demand is exactly quadratic — so the restraint that is indifferent to where it is attached is the one that gets expensive fastest.
The damper is only as good as its brace
A viscous damper added to a frame is held by a brace, and the brace is a spring in series with it. That pair has a ceiling: the most damping it can add is (√(1+κ) − 1)/2, κ being the brace's stiffness over the frame's, reached at one damper size and lost on either side of it. A brace as stiff as the frame allows 20.7%; a quarter as stiff, 5.9%. A damper larger than the best one is not better — it strokes less, locks, and turns the brace into a strut that moves the resonance instead of flattening it.
The damper sized for the earthquake
A fluid damper whose force goes as its velocity to the power 0.3 is chosen because it caps the force a large earthquake can push through its brace. The same exponent makes its effective size depend on how far it strokes. Sized to its brace's best at the earthquake's amplitude, it adds 20.7% of critical damping there, 5.4% at three-tenths of it, and nothing at all at a tenth — where the brace has locked, the building is stiffer, and the motion its occupants feel meets a resonance that is as sharp as an undamped frame's. Giving half the brace to a linear damper keeps 9.3% under the wind for 1.2 points at the earthquake.
The lever that moves the damper and not the band
A damper whose force goes as a low power of its speed is sized for the earthquake and locks in the wind. A toggle or scissor linkage multiplies its stroke, and it seemed it might move the band of amplitudes the damper serves down towards the wind. It cannot. Behind a lever of ratio f the same damper acts on the storey as one f to the power 1 + α larger, so its band moves up, not down; re-sized to the design amplitude, it gives the storey exactly the curve it had without the lever, and what has changed is the damper — a quarter of the size, a third of the force, three times the stroke. What would widen the band is a ratio that grows with the motion, and a toggle has one — until its links lie straight and it locks.
Named alongside it
The objects these essays reach for when they reach for this one.
DampingViscous damperEigenvalueEnergy dissipationLoss factorNatural periodNon-linear responseResonanceSeries stiffnessStiffenerWind loadBearing