Natural period — where it appears
Named by 31 essays across 3 fields — each of them below, with the objects they name alongside it.
Twice the deflection, for the same load
A weight placed gently on a beam deflects it by one amount. The same weight let go from rest, a millimetre above the same beam, deflects it by twice as much — and the factor of two is exact, for every structure ever built.
The period nobody chose
Every structure has a natural period, it decides the answer to every question in this field, and no drawing anywhere records it. It is a consequence of a mass picked for one reason and a stiffness picked for another — and it has already been computed, by the serviceability check.
A structure has more than one period
One mass on one spring has one period. A building with eight floors has eight, each with a shape of its own, and the second one bends the building into a curve nobody drew. They are not harmonics, they do not interfere, and each behaves as though the others were not there.
The spectrum is not a load
A response spectrum looks like a load curve and is not one. Every point on it is the peak of a complete time integration of one particular structure, and the curve is what you get by doing that again for every structure there could be.
The train that arrives in time with itself
A single load crossing a span is a mild problem. A train is not one load — its axles are regularly spaced, so the forcing has a frequency of its own, and where a multiple of it lands on the bridge's frequency each coach arrives exactly in step with the motion the last one left behind.
Made weaker on purpose
Everything else in this collection resists a load by being stiff or strong enough for it. A base-isolated building resists an earthquake by refusing to hear it — a layer of bearings under the whole structure with a lateral stiffness a twentieth of the frame's, bought with almost no strength at all.
The ground is a spring
Every dynamic result in this collection has assumed a structure rising from something that does not move. Nothing does. A foundation can slide and it can rock, both are flexibilities in series with the structure's own, and the rocking one carries a square of the height — so the period lengthens, the force falls, the drift rises, and the damping goes the wrong way.
The load that is over before it has moved
A blast delivers an enormous pressure for a few milliseconds. Everything else in this field asks what force a structure can carry; a load that has come and gone before the structure has travelled any distance is not asking that question, and the answer turns out to depend on the mass and the ductility with the strength barely in it.
The liquid has a period of its own
Shake a tank and its contents do not all go with it. Part of the liquid moves as though it were bolted to the wall and part sloshes at a period fixed by gravity and the radius, which the tank's stiffness has no influence over whatever. The split is decided by one proportion, and the two parts then take entirely different amounts of the earthquake.
The block that is safer for being bigger
A block resting on the ground lifts off at an acceleration that depends only on its shape and not at all on its size, and then falls over at one that depends strongly on its size. Two objects of identical proportion begin rocking at the same instant and only the smaller one topples — which is why the slender water towers stood in Chile and the squat tanks beside them did not.
The ground has a period of its own
An earthquake is measured on rock and felt on soil, and between the two is a layer that behaves exactly like a structure — a column fixed at bedrock, free at the surface, with a fundamental period of four times its depth over its shear wave velocity and a set of odd harmonics above it. The motion a building receives is the rock motion through that filter, and the filter is sharp.
The resonance that ran out of time
A resonance amplifies by one over twice the damping, which for a lightly damped structure is fifty or a hundred. That is a steady-state answer and it takes time to arrive — with a time constant containing the same small damping — so nothing that sweeps through a resonance ever collects all of it, and past a certain rate the peak reached stops depending on the damping at all.
The deck that is its own cable
Every other cable structure hangs something from the cable. A stressed ribbon hangs nothing — the walking surface is the catenary, laid at a fiftieth of the span rather than a tenth, because a footbridge has to be walkable. That one decision hands the abutments six and a quarter times the entire weight of the bridge.
The gap between two buildings
Two towers side by side in an earthquake need a gap. The obvious answer is the sum of what each can move, and it is wrong — because the two peaks do not happen at the same instant. What decides the answer is the ratio of the two periods, and buildings that sway alike need almost no gap at all.
The force read off a frequency
Nothing can measure the tension in a stay cable directly — there is no gauge, no accessible end and no place to put a load cell. What there is, is a member whose frequencies are an arithmetic progression whose spacing is the square root of its own tension, so a phone taped to it for thirty seconds returns the force.
The modes that were left out
Nobody runs every mode a model has, and the rule for how many is a mass count — enough to account for ninety per cent of the structure. The rule is written in the one quantity that converges fastest. On a twenty-storey frame two modes give the base shear to within one per cent and the force in the top storey to within twenty.
The pier that moves in jumps
A sliding bearing whose static friction is larger than its kinetic friction does not release a slow thermal movement as a drift. It grips, gives and grips again, and each time the force in the pier swings by twice the difference between the two coefficients — whatever the pier is made of.
The damper that ends up as a joint
A damper across the gap between two buildings acts on exactly the motion the gap is sized for, and it can be sized for two different things. The size that takes the most energy out of the pair still lets the buildings collide. The size that keeps them apart has nearly stopped moving: it has joined them into one building, and the stiffer of the two pays for it in drift.
The twist the combination rule invents
Two modes close together respond together, and the square root of the sum of squares assumes they do not. The error has the sign of the two modal contributions: where they agree, as they do in base shear, the rule comes up short, and where they oppose, as they always do in torque, it comes up long — by a factor of five for a floor whose stiffness sits twenty centimetres off its mass, a torque the building does not have.
The damping that belongs to no mode
Give every mode its own damping ratio and throw the rest of the damping matrix away, and an isolated building's periods and damping come out right to within a fifth of a per cent. Its storey drift at the superstructure's frequency comes out six times too small. The bearings' dashpot pushes on both modes at once, and the more of it there is the less extra damping buys: the classical analysis promises the drift keeps falling, and it stops.
Two modes that are really a plane
A building equally stiff in both directions has two translational modes with one period, and they are not a pair of shapes but a whole plane of them. The pair an analysis returns is chosen by asymmetries of a millionth, so any result that depends on the pair — a square-root combination, a comparison with measured modes — inherits a choice the building never made. Damping then decides whether the difference can be seen at all.
What a mode shape notices that a frequency does not
Take a tenth of the stiffness out of one storey of a ten-storey building and its first frequency falls by a per cent at most, and by almost nothing if the storey is near the top. The mode shape looks unchanged, its match to the old one 0.99997. But the mode's storey drift — its curvature — rises by about a tenth in the damaged storey and hardly anywhere else, wherever that storey is. The instrument that sees the damage is the one almost nobody installs.
The tank that sloshes the tower
On the ground a tank's liquid splits into a part that moves with the wall and a part that sloshes at its own long period, and the two answers can be added afterwards because they are orders apart. Lift the tank onto a tower and the tower's period moves up towards the sloshing period, the two masses stop being separate, and the system has two modes that belong to neither. Adding the ground answers then overstates the base shear by a third, treating the water as solid by as much again, the wave grows by half, and a flexible tower is worst with the tank about five-sixths full.
The damper is only as good as its brace
A viscous damper added to a frame is held by a brace, and the brace is a spring in series with it. That pair has a ceiling: the most damping it can add is (√(1+κ) − 1)/2, κ being the brace's stiffness over the frame's, reached at one damper size and lost on either side of it. A brace as stiff as the frame allows 20.7%; a quarter as stiff, 5.9%. A damper larger than the best one is not better — it strokes less, locks, and turns the brace into a strut that moves the resonance instead of flattening it.
The damper sized for the earthquake
A fluid damper whose force goes as its velocity to the power 0.3 is chosen because it caps the force a large earthquake can push through its brace. The same exponent makes its effective size depend on how far it strokes. Sized to its brace's best at the earthquake's amplitude, it adds 20.7% of critical damping there, 5.4% at three-tenths of it, and nothing at all at a tenth — where the brace has locked, the building is stiffer, and the motion its occupants feel meets a resonance that is as sharp as an undamped frame's. Giving half the brace to a linear damper keeps 9.3% under the wind for 1.2 points at the earthquake.
The tank that is its own tower
A standpipe holds its water in its own shaft, so the water fills a height several times its width. Only a lens of it near the surface sloshes — 0.455ρπR³, 178 t of the 2,199 t in a steel standpipe 10 m across and 30 m tall — and that lens stops growing once the water is deeper than a radius, so its period is set by the width alone: 3.3 s, against the shaft's 0.38. The lens is 8% of the water but a quarter of the shaft's moving mass, because it sits where the shaft moves most. It is far too slow to be tuned as a damper, and a screen can do little with it; what it does instead is stay still while the shaft sways, which takes nearly a fifth off the drift a frozen-water calculation predicts.
The tank that must be shallow to be slow
A deep tank's sloshing period is set by its width alone, so a tank in a tall building's core ought to be tuned by choosing how wide to make it. It cannot be. A deep tank fast enough to fit is too fast for the building: 3.6 s for a core 10 m across, where a 5 s building would need a tank 19.5 m long and an 8 s one 50 m. The depth has to tune it, and only shallow water is slow — 1.73 m for 5 s, 0.63 m for 8. Shallow water is the efficient kind, with four fifths of it sloshing. But at the accelerations the tank exists to reduce, the wave it makes is a quarter of its depth on a 5 s building and seven tenths on an 8 s one, and the linear tuning it was designed by has stopped describing it.
The tank that follows the building
A sloshing damper is tuned to a period computed before the building exists, and the building that is built has another one — stiffer at handover, with its partitions and cladding working, softer once its concrete has cracked. A tank whose plan is fixed and whose period is set by its depth can be brought back by opening a valve. Ten per cent off tune, the tank left alone lets the building's peak response more than double; pumped back to the right depth, it holds within a tenth of the design value, and the water it gains or loses barely matters. What does matter is that a slower building needs shallower water, and in shallow water the wave the damper is made of grows towards the depth it is sloshing in.
The release the rope cannot slow
A crane whose counterweight knows the payload balances only a third of it, because a payload can be let go and the crane is then thrown backwards by whatever the counterweight was holding, and half as much again in the rebound. Slow the release and the rebound goes, so the hope was that a device on the rope could slow it. Nothing on the rope can: the rope holds only what the hook holds. How fast a load goes belongs to the payload, and what the crane owns is how fast it answers — its period and its damping. And with no rebound at all, the counterweight still should not balance more than 0.6 of the payload, because the payload's own moment is still let go.
The bearing that does not know what it carries
A friction pendulum's stiffness is the weight on it divided by the radius of its dish, and from that one line three things follow. Its period has no mass in it. A heavy bearing is a stiff bearing, so the centre of stiffness stands exactly under the centre of mass wherever the mass is put, and an off-centre building does not twist. And when the building rocks and the load shifts across the bearings, the shift is along the very force that caused it, which gives that force no lever arm either. What can bring the twist back is the friction, if it differs from one bearing to the next.
The bearings changed in opposite pairs
A building on friction pendulums does not twist because every bearing's friction is its load times one coefficient, so the friction's resultant passes through the mass. Replace one bearing with a new one and that stops being exactly true. One bearing does almost nothing: about one per cent at a corner. The order of a whole programme does more. Worked from one end of the plan to the other, the halfway state moves the friction's centre 2.5 m and the corner bearings travel 8 per cent further than the mass; worked in pairs opposite each other through the centre, the plan never twists by more than two per cent and is straight again after every second bearing.
Named alongside it
The objects these essays reach for when they reach for this one.
DampingMode shapeModal massResonanceResponse spectrumServiceabilityEigenvalueBase isolationDynamic amplificationModal analysisFree bodyOrthogonality