Base isolation — where it appears
Named by 7 essays across 2 fields — each of them below, with the objects they name alongside it.
Made weaker on purpose
Everything else in this collection resists a load by being stiff or strong enough for it. A base-isolated building resists an earthquake by refusing to hear it — a layer of bearings under the whole structure with a lateral stiffness a twentieth of the frame's, bought with almost no strength at all.
The block that is safer for being bigger
A block resting on the ground lifts off at an acceleration that depends only on its shape and not at all on its size, and then falls over at one that depends strongly on its size. Two objects of identical proportion begin rocking at the same instant and only the smaller one topples — which is why the slender water towers stood in Chile and the squat tanks beside them did not.
The ground has a period of its own
An earthquake is measured on rock and felt on soil, and between the two is a layer that behaves exactly like a structure — a column fixed at bedrock, free at the surface, with a fundamental period of four times its depth over its shear wave velocity and a set of odd harmonics above it. The motion a building receives is the rock motion through that filter, and the filter is sharp.
The damping that belongs to no mode
Give every mode its own damping ratio and throw the rest of the damping matrix away, and an isolated building's periods and damping come out right to within a fifth of a per cent. Its storey drift at the superstructure's frequency comes out six times too small. The bearings' dashpot pushes on both modes at once, and the more of it there is the less extra damping buys: the classical analysis promises the drift keeps falling, and it stops.
The top floor the bearings shake
On a building of several storeys, the damping at the isolation bearings is tied less tightly to each higher structural mode than to the one below. It still does more harm in each, because the ground barely reaches those modes on its own. The error the usual analysis throws away gathers in the upper storeys, and past about a third of critical damping at the bearings the roof shakes harder while the analysis says it is still helping. How much damping is best depends on how tall the building is.
The modes at zero frequency
A structure held by nothing — a span being launched, a segment on a crane, a pontoon — has a mode in which it moves as one body and stretches nothing, at a frequency of exactly zero. That is a real mode, not a glitch in the stiffness matrix. It carries every kilogram of the structure under a uniform acceleration and leaves the flexible modes none at all. A load that is not uniform is a different matter: pushed suddenly from one end, the structure has no static answer to give, only an acceleration with a vibration riding on it.
The bearing Engesser says has buckled
A member that is flexible in shear buckles below its Euler load, and there are two classical formulas for how far below. For a laced column they agree to a fraction of a per cent. For a battened column one gives nearly twice the other. For a laminated rubber bearing, Engesser's says it buckles at a fourteenth of the load it carries every day and Haringx's says it is safe by a factor of nearly three. They are not two theories. Put the axial load into Engesser's shear stiffness and it becomes Haringx's, exactly — so the whole disagreement is about which shear stiffness was measured.
Named alongside it
The objects these essays reach for when they reach for this one.
Mode shapeDampingNatural periodDuctility demandModal massResonanceEigenvalueEnergy dissipationFree bodyFrequency responseModal analysisOrthogonality