Deflection

The reading that points the wrong way

A continuity joint jacked as it is cast is set for a humidity nobody knows, and the jacks can stay in and read what the joint is doing. Reset a year after a late slab, from the reading and the design model's forecast, the thirty-year moment's spread across 45 to 80 per cent humidity falls from −32…126 kN·m to −2…22. Do the same a year after an early slab and the spread grows, from −1…30 to −2…40, because at one year the early slab's error has the opposite sign from the one it will have at thirty.

Assumes The angle nobody limits, The deflection that arrives three years late and The moment over the support, and what it buys.

The joint born holding a moment took two 12 m pretensioned beams, made them continuous over their pier in one pour with the slab, and jacked a moment into the joint as it was cast, chosen to cancel the restraint moment that creep and shrinkage would bring it to at thirty years. The arithmetic worked for any date, but the jack was set for one humidity and the beams would creep in another. With the jack set for 60 per cent, a slab cast at six weeks ended its thirty years between −1 and 30 kN·m anywhere from 45 to 80 per cent humidity, because its restraint and its jack both creep, and both creep more in dry air. A slab cast at a year ended between −32 and 126, because by then most of the restraint comes from the slab’s own shrinkage, and the jack’s relaxation and the slab’s shrinkage do not move together.

The essay ended on the obvious remedy. The jacks need not be removed. Left in under the beams’ ends, a jack holding a support at a known level reads the reaction there, and a reaction is the joint’s moment in another form. A year of readings tells the engineer how the joint is actually creeping, and the jacks can be reset from it — a second correction, made when much of the creep has happened and the doubt about the rest is smaller. The jack that creep carries past the mark asked the same question of a continuous beam’s closure jacks and left it open; here it can be answered.

The jacks read the joint, and the reset takes the error out. For two 12 m pretensioned beams made continuous over their pier in one pour with the slab, the first jack set to leave the joint with nothing at thirty years in 60 per cent humidity, a slab cast at a year: the joint's moment, sagging positive, over thirty years in 45 and 80 per cent humidity, jacked once (dashed) and reset 1 year after the slab from the jacks' own reading (solid). Jacked once, the joint ends at −32 kN·m in dry air and 126 in humid. The jacks read −39 and 89 kN·m on the day; reset by 56 and −171, the joint ends at −2 and 22.
Fig. 1 The joint’s moment over thirty years for the slab cast at a year, in 45 and in 80 per cent humidity: jacked once (dashed), and read and reset a year after the slab (solid). The reset is a step on the day; afterwards each curve creeps toward an end close to nothing.

Reading, forecasting, resetting

The second jack has three ingredients. The reading is the joint’s moment on the day, which the jacks measure directly. The forecast is what that moment will become by thirty years if nothing is done, and it has to come from a model — the same creep and shrinkage model the first jack was set with, run at the design humidity. And the reset is a second jacked moment M2M_2, which from the day it is applied is relaxed by the beams’ creep just as the first was, but as a step at an older age: a year after a slab cast at a year, the beams are two years old, and the reset keeps 0.57 of itself at thirty years in 60 per cent humidity against the first jack’s 0.39 to 0.53.

The natural rule, and the one followed here unless said otherwise, is to forecast the thirty-year moment as the reading plus the design model’s own change from the reading’s day to the end, and to set M2M_2 so that, relaxed by the design model’s creep, it cancels that forecast. If the beams are creeping at the design humidity, the reading equals the model’s prediction and M2M_2 is nothing. If they are creeping in drier or wetter air, the reading differs from the prediction by however much the humidity has moved the first year, and the reset carries that difference forward.

In the hero figure, a slab cast at a year in dry air at 45 per cent reads −38.8 kN·m on the day against the model’s −7.2. The reset adds 55.9 kN·m of sag and the joint ends at −1.8 instead of −31.7. In humid air at 80 per cent it reads +89.1, the reset takes off 170.6 and the joint ends at 22.1 instead of 125.8. The reading has seen most of what humidity was going to do to the joint, because for a slab cast at a year the humidity’s main effect is the slab’s shrinkage, and the slab shrinks fastest in its first year.

The late slab: one reading takes most of the doubt away

Running the whole humidity range shows how much the reading is worth.

For a slab cast late, one reading takes most of the doubt away. For two 12 m pretensioned beams made continuous over their pier in one pour with the slab, the first jack set to leave the joint with nothing at thirty years in 60 per cent humidity, a slab cast at a year: the moment at thirty years against the humidity the beams actually creep in. Jacked once it runs from −32 to 126 kN·m between 45 and 80 per cent. Reset from the jacks' reading 90 days after the slab, from −9 to 56; after a year, −2 to 22; after three years, −1 to 6.
Fig. 2 For the slab cast at a year: the joint’s moment at thirty years against the humidity the beams actually creep in, jacked once and reset at three delays after the slab. Every reset narrows the spread, and later readings narrow it more.

Jacked once, the thirty-year moment runs from −32 to 126 kN·m across 45 to 80 per cent humidity — a spread of 158. Reset from a reading ninety days after the slab, it runs from −9 to 56; after a year, from −2 to 22; after three years, from −1 to 6. The late slab rewards any reading, and the longer the wait, the less is left to forecast and the more the forecast’s errors shrink with it.

That is the result the remedy was proposed for, and for this slab it delivers. Its error comes mostly from shrinkage, which is a strain the slab imposes on the joint whatever the beams are doing, and it arrives early: a reading in the first year sees the sign and most of the size of the shrinkage’s departure from the design model, and the reset cancels it. What the reading cannot see is the rest of the beams’ creep, but that is the smaller part of this slab’s error.

The early slab: an early reading makes things worse

The slab cast at six weeks behaves quite differently.

For a slab cast early, an early reading makes things worse. For two 12 m pretensioned beams made continuous over their pier in one pour with the slab, the first jack set to leave the joint with nothing at thirty years in 60 per cent humidity, a slab cast at six weeks: the moment at thirty years against the humidity the beams actually creep in. Jacked once it runs from −1 to 30 kN·m between 45 and 80 per cent. Reset from the jacks' reading 90 days after the slab, from −4 to 60; after a year, −2 to 40; after three years, −1 to 19.
Fig. 3 For the slab cast at six weeks: the thirty-year moment against the humidity, jacked once and reset at three delays. A reset at ninety days or at a year widens the spread; only a reading three years after the slab narrows it.

Jacked once, the early slab’s joint ends between −1 and 30 kN·m — a spread of 31, already small, because its restraint moment and its jack’s relaxation both come from the beams’ creep and both grow with dry air, so their errors largely cancel by thirty years. Reset from a reading ninety days after the slab, the spread is −4 to 60. A year after, −2 to 40. Only three years after does it fall below the single jack’s, to −1 to 19.

The numbers in humid air show why. At 80 per cent, a year after the slab, the jacks read −91.6 kN·m. The design model, at 60 per cent, expected −82.1, so the joint is 9.5 kN·m more hogging than forecast. The forecast rule takes that as an error that will persist and resets the joint by 17.8 kN·m of sag. But the joint jacked once was heading for +29.6 kN·m — sag — at thirty years. At one year its error is in hog; at thirty it is in sag. The reading is accurate, and it points the wrong way.

This is the first refutation, and what makes it possible is visible in the joint’s history rather than in any one number. The joint’s moment is the sum of several things humidity changes by different amounts at different ages: the first jack relaxing by the beams’ creep, the beams’ own creep under their prestress and weight, and the slab’s shrinkage against them. In humid air the first jack relaxes more slowly, which leaves the joint more hogging in its early years than the model expected; the other parts change too, each on its own time scale. So the error between the humid joint and the design model is in hog at first and in sag later, and it crosses zero part way through. A reading taken before the crossing sees an error of the opposite sign from the one that will matter, and the reset faithfully corrects it the wrong way.

Where the error crosses

The error can be followed directly: the joint jacked once in the actual humidity, minus the design model’s joint at 60 per cent, day by day. For the early slab in humid air it is −28.0 kN·m three months after the slab, −9.5 at a year, +2.7 at two years, +16.3 at five, +23.4 at ten and +29.6 at thirty. It passes through zero 644 days after the slab. Any reading before that day sees a hogging error on its way to a sagging one, and a reset made from it adds sag to a joint that will acquire plenty of its own.

In dry air at 45 per cent the early slab’s error does not cross. It is +16.2 kN·m at three months, +14.6 at a year and +11.7 at thirty, so a reading at any time overstates the final error a little, and the reset overshoots by a little: the joint ends at −2.0 instead of the single jack’s +11.7, which is better but on the other side. The early slab’s trouble is entirely in humid air, where its error changes sign.

The late slab’s error is a different shape altogether. In humid air it is +64.1 kN·m three months after the slab, +94.9 at a year, +106.8 at two years and +125.8 at thirty: three quarters of its final size within the first year and never changing sign. In dry air it reaches −31.3 by one year and stays within a kN·m of that for the next twenty-nine. A reading of an error that has already mostly arrived and will not reverse is the best kind of evidence there is, and the reset uses it.

So the picture behind the next figure is simple. A reading is worth acting on once the error it sees has the sign, and most of the size, it will have at the end. For the late slab that is true within months. For the early slab it is true only after the crossing, and the crossing is at about the time the next figure finds.

How long to wait

So the value of the reading depends on when it is taken, and differently for the two slabs.

How long to wait before trusting the jacks. For two 12 m pretensioned beams made continuous over their pier in one pour with the slab, the first jack set to leave the joint with nothing at thirty years in 60 per cent humidity: the spread of the thirty-year moment between 45 and 80 per cent humidity, against how long after the slab the jacks are read and reset, for a slab cast at six weeks and one cast at a year; dashed, each slab's spread jacked once, 31 and 158 kN·m. The late slab's spread falls below its single jack's at the first reading and to 24 kN·m at a year. The early slab's is wider than its single jack's until the reading is 1.81 years after the slab, and only then falls below it.
Fig. 4 The spread of the thirty-year moment across 45–80 per cent humidity against how long after the slab the jacks are read and reset, for both slabs, with each slab’s spread jacked once dashed. The late slab gains from any reading; the early slab only from one taken after about two years.

For the late slab the spread falls below its single jack’s 158 kN·m at the earliest reading and keeps falling: 24 kN·m at a year. For the early slab, whose single jack already leaves only 31, the reset makes things worse until the reading is 1.8 years after the slab and only then improves on doing nothing more. By ten years either reset leaves a spread of a few kN·m, but a reset at ten years is a reset after most of the joint’s life has already been spent at the wrong moment.

So there is a practical rule here, and it is not “read as soon as possible”. It is: know which mechanism the joint’s error comes from. If it comes from something that happens early and is not reversed — shrinkage of a slab cast late — read early. If it comes from two creeping effects that cancel by the end — a jack and a restraint growing together in an early slab — the reading must wait until the cancellation has had time to show, or it will undo it.

A reading is worth what its forecast is worth

The reset needs a forecast because the reading describes the past, and the jack has to act on the future. Three rules for turning a reading into a reset compare.

A reading is worth what the forecast after it is worth. For two 12 m pretensioned beams made continuous over their pier in one pour with the slab, the first jack set to leave the joint with nothing at thirty years in 60 per cent humidity, a slab cast at a year, reset 1 year after it: the thirty-year moment against the humidity, for three rules for the second jack. Bringing the joint to nothing on the day of the reading ends it between −11 and 72 kN·m, and at 4 even at the design humidity: what the joint has done so far is cancelled, what it will still do is not, and the reset itself then relaxes. The reading plus the design model's change from then on, −2 to 22, centred on nothing at the design humidity; the same change scaled by the ratio of the change read to the change the model predicted so far, −2 to 24.
Fig. 5 For the slab cast at a year, reset a year later: the thirty-year moment against the humidity for three rules — the reading plus the design model’s remaining change, the same with that change scaled by the model’s error so far, and the joint simply brought to nothing on the day.

Bringing the joint to nothing on the day of the reading — the intuitive rule — ends it between −11 and 72 kN·m, and at 4 even at the design humidity. What the joint has done so far is cancelled; what it will still do is not, and the reset itself then relaxes. That is the second refutation: a joint at zero moment on its second birthday is not a joint at zero moment on its thirtieth. The reading plus the model’s remaining change ends it between −2 and 22, centred on nothing at the design humidity. Scaling the model’s remaining change by the ratio of the change read to the change predicted so far, a model corrected by its own error, ends it between −2 and 24 — no better, because the ratio of past changes is a poor guide to the ratio of future ones when the past and future are driven by different mechanisms.

The lesson is that the reading is not a substitute for the model; it is an input to it. A measurement of a creeping structure says where it is. Where it is going is a forecast, and the forecast is only as good as the model behind it — which is the uncomfortable position the first jack was in, with a year less doubt.

The second jack is small

A reset is a jacking operation on a joint that is already in service, and it must not crack the joint it is meant to correct.

The second jack is small beside the first. For two 12 m pretensioned beams made continuous over their pier in one pour with the slab, the first jack set to leave the joint with nothing at thirty years in 60 per cent humidity, reset 1 year after the slab: the second jacked moment against the humidity, sagging positive. For the late slab it runs from 56 kN·m in dry air to −171 in humid, beside a first jack of 407; for the early slab from −27 to 18, beside −413. Both stay inside the joint's cracking moments, 140 kN·m in sag and 239 in hog, so the reset can be made without cracking the joint it is correcting.
Fig. 6 The second jacked moment against the humidity, for both slabs, reset a year after the slab, beside the joint’s cracking moments in sag and in hog. Both slabs’ resets stay inside them.

For the late slab the second jack runs from 55.9 kN·m of sag in dry air to 170.6 of hog in humid air, beside a first jack of 407 kN·m of sag. For the early slab it is −27.3 to +17.8, beside a first jack of 413 of hog. The joint cracks at 140 kN·m in sag and 239 in hog, so every reset stays inside its own sense’s cracking moment, and the late slab’s largest reset uses 71 per cent of the hogging margin. The first jack exceeded both cracking moments, which the earlier essay found and left as the price of cancelling a large restraint in one step. The second jack is the correction of a correction and is small for the same reason: most of the job was done the first time.

What the joint’s model rests on

The humidity is constant for thirty years, and different from the design value. Real air varies by season and over decades. A constant humidity off the design value is the simplest way to represent a systematic error in the creep and shrinkage model, and it is the error a reading can detect. A random, seasonal error averages out and gives the reading nothing to act on.

The model is right apart from its humidity. The forecast rule is exact when the beams creep at the design humidity and is tested here against beams that creep at another, with every other part of the model shared. A model wrong in its form — a creep function of the wrong shape, an ageing coefficient that is not the concrete’s — would leave the reading a different kind of error to correct, and the late slab’s gain would be smaller.

The jacks read without error. A jack’s reading of a reaction has a resolution, and a reaction is the joint’s moment divided by a span; for a 12 m span a 2 kN error in a reaction is 24 kN·m in the moment, the size of the spread the reset leaves. The gain from a second jack is only as good as the reading behind it.

The beams are the earlier essays’ beams. Two 12 m pretensioned beams, 300 mm wide and 700 deep, with a 160 mm slab 1.2 m wide, made continuous over their pier in one pour, their creep by EN 1992-1-1’s ageing coefficient through a step-by-step creep integral, the beams’ own creep and the slab’s separately. The joint’s first stage and its slab are cast together, as in the essay on the joint born holding a moment; a joint poured twice over the pier would have a different restraint history and its own reading to interpret.

Measurement as a second chance, and when it is not

Observational methods in geotechnics work this way, and so do the staged jacking of arches and cable-stayed decks: a structure whose behaviour depends on uncertain time-dependent properties is built with a means of adjustment and adjusted as it reveals itself. The arch that waits with its hinges open found that an arch closed late carried less than one jacked again on the same date, because the jacked arch remembers its first year. Here the joint remembers its first year too, and whether that memory helps depends on whether the first year resembles the thirty.

It is worth carrying beyond this joint. A measurement is evidence about the past. Acting on it is a bet about the future, and the bet is good when the error the measurement reveals persists — the late slab’s shrinkage — and bad when it is about to reverse — the early slab’s race between relaxation and restraint. The reading cannot tell which; only the model can, which is the same thing the deflection that arrives three years late found about every forecast of creep. The jacks give the engineer better information. They do not relieve the engineer of knowing what it means.

Still open: readings taken every year

Every reset here is a single step on a single day. Jacks left in permanently could be read every year and reset every year, each reset small, each made with one more year of evidence and one less year of future to forecast. For the late slab that would converge quickly; for the early slab the first few resets would push the joint the wrong way, and later ones would have to undo them, with each reset relaxing at its own age. Whether a programme of annual resets does better than one reset at the right moment — and whether it does better than leaving the early slab’s single jack alone — needs the reset rule run as a sequence, with every past reset part of the history the next reading sees.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

The objects this essay names

Each one links to every other essay that touches it.

ContinuityCreepEnd rotationPrestressRelaxationShrinkage