Concept

Lower-bound — where it appears

A load that a structure is proved able to carry, from an equilibrium system nowhere exceeding the material's strength. It is the safe side to be on, which is why every practical plastic design method is a lower-bound one.

Named by 5 essays across 4 fields — each of them below, with the objects they name alongside it.

A line of thrust, and the masonry it has to stay inside. An arch ring of 9% of the span in thickness, rising 28% of the span, under its own weight as a uniform load. Any horizontal thrust between 3.85 and 5.23 puts a line of compression entirely inside the masonry, so the arch stands — and which of them it actually takes is not decided by statics. The two extremes are drawn: the minimum-thrust line, which rides high at the crown and low at the haunches, and the maximum-thrust line, which does the opposite.

The line that must stay inside

A masonry arch does not stand because its shape is right. It stands because some line of compression can be drawn inside the stonework — any one will do, and there are infinitely many to choose from.

structures · Arch
The collapse mechanism of a propped cantilever. A collapse mechanism, with the hinge position found by searching rather than quoted. Every position gives an upper bound on the collapse load; the lowest is 7.29, at a hinge 58.6 per cent along, which is a coefficient of 11.657 times Mp over the square of the span.

After the first yield, which is not the end

A steel beam whose extreme fibre has reached yield has not failed. It has started forming a hinge, and collapse waits until there are enough hinges to make a mechanism.

internal-forces · Plastic hinge
The corner is where the plate twists, and it has to be held down. The twisting moment M_xy over a 6 × 6 m simply-supported panel under 10 kN/m², from Navier's double series. It is zero along both centrelines and largest at the corners, which is the opposite of the bending moments and is why no strip reading contains it: 31% of the load crosses this panel in twist, and a strip can only bend. At a free corner the twisting moment is statically equivalent to a downward point force of 2M_xy — 26.7 kN here, 7.4% of the whole load on the panel, applied at a point — so the corner has to be held down. A panel whose corners are free lifts there, deflects more, and cracks diagonally across them. The deflection at the centre is 2.53 mm, against 4.05 mm for the strip that ignores all this — 60% more, which is the size of what the twist is carrying.

A third of the load crosses sideways

A slab spanning both ways is usually explained as two beams sharing a load by a fourth power, and the explanation is not merely approximate — it is missing a mechanism. A real plate carries load three ways, and the third one has no beam strip in it: it is twisting, it accounts for a third of the load on a square panel, and it is why the corners lift.

deflection · Plate torsion
The middle third, computed. The kern of a 300 × 600 mm rectangle, computed by asking, for every direction, how far the resultant can move before the far face would be pulled. It reaches ±100.0 mm vertically and ±50.0 mm horizontally, which are h/6 and b/6 exactly, and the region between is a rhombus rather than the ellipse the two numbers suggest — a resultant on a diagonal has less room than either axis allows.

The strength thrown away on purpose

Masonry, concrete and soil are all analysed as though they had no tensile strength whatever. Each of them has some. The decision to set it to zero is the single most consequential modelling assumption in the subject, it is safe for one kind of check and unsafe for another, and almost nothing that uses it says which.

materials · No tension
Settling down or walking away, cycle by cycle. The total plastic hinge rotation of the beam after each cycle of loading — span 1, both, span 2, neither — with the midspan load at 0.98, 1.02, 1.05, 1.10 times the shakedown load of 126.3 kN. At 0.98 it stops at 0.59 mrad. At 1.02 it grows 4.57 mrad a cycle. At 1.05 it grows 11.43 mrad a cycle. At 1.10 it grows 22.86 mrad a cycle. Nothing collapses in any single cycle; above the shakedown load the beam walks.

The load it can carry once

A two-span beam whose loads come and go span by span collapses at 150 kN under any one arrangement, and walks at 127. Between the two it can carry every arrangement once and none of them forever: each cycle leaves a few more milliradians of rotation at the support and a midspan fifteen millimetres lower. Melan's theorem finds the limit as the last residual moment line that fits, Koiter's as a mechanism no single load state can drive, and a cycle-by-cycle calculation walks exactly where both say it will.

materials · Shakedown

Named alongside it

The objects these essays reach for when they reach for this one.

Moment redistributionPlastic hingeThrust lineUpper boundBearing pressureBrittlenessCollapse mechanismContinuous beamCorner upliftCracked sectionCurvatureDeflection

All concepts