Which failure arrives first — page 24
The bow that points the wrong way round
A horizontal tube strut bowed upward by the sag its own weight would give it stays a two-force member from 40 kN to its Euler load. Turn the same bow fifteen degrees off vertical and the top of that window drops to 266 kN; turn it on its side and the window is 50 to 209, worse than a straight tube's. The tube is round, so its gap is a vector and its kern a disc, and a bow's sideways part has nothing in the weight's plane to cancel it. The plane of the bow needs to be found to a few tens of degrees, not to one — and a tube left lying on the floor is found at the worst angle short of upside down.
The lining the mass must not crush
A wind-tuned mass inside a ring of hard stops strikes them two or three times in a moderate earthquake, each strike a blow of a seventh of its weight. Line the ring with a soft layer 80 mm thick and the strikes stop: the mass meets the lining instead and is pressed back at half the force. But a lining is not better for being softer. It has to stop the mass inside its own thickness, so it has a stiffness floor set by the speed the mass arrives at, and the best lining for a strong earthquake is three times stiffer than the best for a moderate one. Below the floor the mass drives straight through to the ring.
The axle the range cannot see
A Vierendeel girder's members were sized for fatigue by giving each one cycle of its stress range per crossing. Counted properly, by rainflow over every member's whole history, a single axle's crossing turns out to be exactly that — one cycle, for every post and every chord. What the range cannot see is a second axle. Two axles closer than about five metres still write one cycle; past that the middle post sees two, and once the axles are a span apart every member does, and the range understates the stress each member can be sized to by a quarter.
The coefficient that answered the wrong question
The age-adjusted effective modulus turns a creep integral into one line with an ageing coefficient in it, quoted as 0.8. Fed a strain imposed at once and held, the line seemed to need 1.32 on one creep function and 1.67 on another — evidence, it appeared, that the coefficient is no constant at all. It was the wrong line. The method has a second form for a held strain, and in that form the same concrete needs 0.90; so does the stress that grows from nothing. One coefficient answers both questions, and derived properly it always lies between a half and one.
The ground that holds the tube round
A thin steel tube bent along its length flattens into an oval, and Brazier's limit — 796 kN·m for a 1.2 m tube with a 2.5 mm wall — is where the flattening wins. Bury it, and the soil pressing on its sides resists every millimetre of that oval. In ground as stiff as an ordinary compacted fill the limit rises sixteenfold, far past the moment at which the wall itself buckles, so a buried tube is never governed by Brazier at all. What the ground decides instead is the oval the cover's own weight makes before anything bends, and that is set by the soil and hardly by the tube.
The post that hands the shear across
Two web openings side by side are usually staggered, one high for a duct and the next low for a pipe. Each is an offset hole whose deep tee is on the opposite side from its neighbour's, so the strip of web between them has to move most of the shear from the bottom of the beam to the top. Two 300 mm holes a diameter and a half apart, staggered 50 mm each way, leave a post that fails at 3.3 times the load where the same holes in line leave one that outlasts the holes at 5.8 — and the post governs all the way to mid-span, where the shear it hands across has gone and the step in the top tees' thrust has taken its place.
The last reading is the one that counts
Jacks left in under a precast continuity joint can be read and reset every year, each reset made with one more year of evidence. The programme does not converge on its target the way that sounds. Whatever the earlier resets did, the joint ends where the design model's error after the last reading puts it — an early slab in humid air ends at 12.4 kN·m after five annual resets and at 11.4 after one reset on the fifth reading's day, having moved the jacks less than half as far. Resetting the joint to nothing every year instead keeps it near nothing all the way, and buys a path the joint never needed.
The traffic that comes the other way
Counting a Vierendeel girder's fatigue vehicle by vehicle assumes the order of the traffic does not matter. Counted instead as one history, by rainflow across 2,000 mixed vehicles, the order turns out not to matter at all to any member whose stress keeps one sign, and to matter by under a per cent to the posts whose stress reverses — so long as the traffic goes one way. Traffic in both directions changes the count, and in the safe direction: a vehicle crossing the other way swings the middle post down where its neighbour swung it up, the unloaded girder between them splits a swing in two, and the whole stream does three per cent less than its vehicles counted apart.