Deflection

The swap that survives resonance

Shake a beam at A and read it at B, then shake it at B and read it at A, and the two readings are the same curve at every frequency — through every resonance, with every dashpot attached. One loop from a sensor to an actuator parts them, and the place it parts them is the place where a mode is shared rather than alone.

Assumes The theorem that swaps the question round, A structure has more than one period and The actuator that arrives late.

Push here and measure there; push there and measure here: Maxwell’s theorem says the two readings are equal for any linear elastic structure, and an influence line is a deflected shape because of it. Both of those are statements about a structure standing still. The load is applied slowly, the structure settles, and the reading is taken when nothing is moving.

A structure that is shaken is a different object. It has mass, which makes the response at each frequency different from the static one by factors of tens near a resonance. It has damping, which puts the response out of phase with the force. And it has more than one natural frequency, each with its own shape, so the response at a point is a sum of contributions that rise and fall at different rates as the frequency changes. None of that is obviously compatible with a swap that was proved by equating two quantities of strain energy.

The claim of this essay is that the swap survives all of it, exactly, and that the conditions under which it does are narrower and more interesting than “linear and elastic”. The assumption the figures rest on is named now: every force acting on the structure is a symmetric function of the motion — a spring, a mass, a dashpot, each pushing equally and oppositely on the two points it connects. The last two figures break that assumption on purpose.

Two readings that are one curve

The structure is a 12 m simply supported beam with a flexural rigidity EI=2×108 N m2EI = 2\times10^{8}\,\mathrm{N\,m^2} and 1,500 kg of mass per metre — roughly a composite floor beam or a light footbridge, with its first natural frequency at 4.0 Hz. A is 3 m from one end and B is 8 m, chosen so that neither is at mid-span and the beam has no symmetry that could make the two readings equal by accident.

Push at B and read at A, or push at A and read at B. The receptance of a 12 m simply supported beam, A 3.0 m and B 8.0 m from one end, in millimetres per kilonewton of harmonic force on a logarithmic scale, from nothing to 40 Hz, with 2.0 per cent damping at the first and third modes. The two transfer receptances, force at B read at A and force at A read at B, lie on each other at every frequency, differing by less than a billionth of their size; at the bottom of the band both are 0.099 mm/kN, Maxwell's static flexibility. The two driving points do not agree with each other or with the transfer: A peaks at 2.18 mm/kN at 4.0 Hz, 0.44 mm/kN at 16.0 Hz, 0.03 mm/kN at 35.9 Hz; B at 3.26 at 4.0 Hz, 0.33 at 16.0 Hz.
Fig. 1 The receptance of a 12 m simply supported beam, A 3.0 m and B 8.0 m from one end, in millimetres per kilonewton of harmonic force on a logarithmic scale, with 2.0 per cent damping at the first and third modes. The two transfer receptances lie on each other at every frequency, differing by less than a billionth of their size; at the bottom of the band both are 0.099 mm/kN, Maxwell’s static flexibility. The two driving points disagree: A peaks at 2.18 mm/kN at 4.0 Hz, B at 3.26.

The quantity plotted is the receptance: the amplitude of displacement at one point per unit amplitude of a harmonic force at another, at each frequency. A driving point is a receptance with the force and the reading at the same place. A transfer receptance has them at different places.

The two transfer receptances, with the force at B and the reading at A and with the force at A and the reading at B, are one curve. They are one curve at 0.05 Hz, where both are 0.099 mm/kN — which is the static flexibility the beam formula gives for a load at 8 m and a deflection at 3 m, Maxwell’s number. They are one curve through the first resonance, where the response rises by a factor of about twenty-seven, and through the second, and through the long fall above it. They differ by less than a billionth of their size anywhere in the band, which is the arithmetic’s own rounding.

The two driving points are not one curve and were never going to be. B is nearer mid-span, where the first mode is larger, so B’s peak is half as high again as A’s: 3.26 against 2.18 mm/kN. A sees a third resonance at 35.9 Hz that B does not. A has deep notches at 9.6 and 31.5 Hz, B one at about 11 Hz. The swap does not say that the beam responds the same way everywhere. It says something narrower and far less obvious: that the influence of A on B is the influence of B on A, and that this survives the beam being driven at resonance.

Each mode multiplies two ordinates

The reason is visible in the modes, and the shapes make it nearly a tautology.

Each mode multiplies the two ordinates, and multiplication does not care about order. The first three mode shapes of a 12 m simply supported beam, A 3.0 m and B 8.0 m from one end, each scaled to one at its largest, at 4.0 Hz, 15.9 Hz, 35.8 Hz. A mode's contribution to the receptance between two points is the product of its ordinates there over its own dynamic stiffness: 0.71 × 0.87 for mode 1; 1.00 × -0.87 for mode 2; 0.71 × 0.00 for mode 3. The same product serves the swapped pair. B sits on a node of the third mode, so that mode contributes nothing between A and B in either direction.
Fig. 2 The first three mode shapes of the same beam, each scaled to one at its largest, at 4.0, 15.9 and 35.8 Hz. A mode’s contribution to the receptance between two points is the product of its ordinates there over its own dynamic stiffness: 0.71 × 0.87 for mode 1, 1.00 × −0.87 for mode 2, 0.71 × 0.00 for mode 3. B sits on a node of the third mode, so that mode contributes nothing between A and B in either direction.

A beam with proportional damping responds to a harmonic force as a sum over its modes. Mode k is excited in proportion to its own ordinate at the point where the force is applied, and it contributes to the reading in proportion to its ordinate at the point where the reading is taken. Each mode behaves like a single mass on a spring with its own resonance, so its contribution is

HAB(ω)=∑kϕk(A) ϕk(B)Mk(ωk2−ω2+2iζkωkω)H_{AB}(\omega) = \sum_k \frac{\phi_k(A)\,\phi_k(B)}{M_k\left(\omega_k^2 - \omega^2 + 2i\zeta_k\omega_k\omega\right)}

with MkM_k the mode’s mass and ζk\zeta_k its damping ratio. The force point and the reading point enter as a product, and a product does not care which factor came first. Swapping A and B swaps the factors and leaves every term unchanged. The resonances, the damping and the phase all sit in the denominator, which belongs to the mode and knows nothing about where the beam is pushed.

The three products in the figure decide most of what the first figure shows. Mode 1 enters the transfer with 0.61; mode 2 with −0.87, because A and B are on opposite sides of its node at mid-span; mode 3 with nothing, because B sits on its node at 8 m. That last one is why the transfer has two resonances in the band and the driving point at A has three. Pushing at B cannot excite the third mode, and by the swap, reading at B cannot see it.

The driving-point terms are squares, ϕk(A)2\phi_k(A)^2, and therefore never negative. That one difference between a square and a product is the whole of what separates the two kinds of curve, and the next figure shows it.

A driving point turns back after every resonance

The phase of the response behind the force is where the difference between a square and a product becomes a rule.

A driving point turns back after every resonance; a transfer need not. The phase of the response behind the force for a 12 m simply supported beam, A 3.0 m and B 8.0 m from one end: at A when A is pushed, and at A when B is pushed. The driving point lags by half a turn through each resonance and then recovers it at an antiresonance, 9.6 Hz and 31.5 Hz, so its phase never leaves the band from 0 to −180°. The transfer has fewer antiresonances and keeps losing phase, reaching -359° by 40 Hz. The swapped transfer has the same phase at every frequency.
Fig. 3 The phase of the response behind the force, at A when A is pushed and at A when B is pushed. The driving point lags by half a turn through each resonance and recovers it at an antiresonance, 9.6 Hz and 31.5 Hz, so its phase never leaves the band from 0 to −180°. The transfer keeps losing phase, reaching −359° by 40 Hz. The swapped transfer has the same phase at every frequency.

Between two resonances the lower mode is being driven above its natural frequency, so its contribution is negative, and the upper mode below its own, so its contribution is positive. In a driving point both numerators are squares and positive, so the two contributions have opposite signs, and somewhere between the resonances they cancel. The response falls to a deep notch, the antiresonance, and the phase swings back by half a turn. That happens between every pair of resonances, so a driving point’s phase oscillates inside a band of half a turn for ever.

The rule has a physical reading that is older than modal analysis. A force pushing on a passive structure at the point where its own motion is measured can only put energy in, never take it out, and that requires the velocity to have a component in phase with the force — which confines the displacement’s phase to the half-turn below zero. The driving point is the one receptance whose shape is guaranteed by the conservation of energy.

The transfer has no such guarantee. Between the first two resonances the products are 0.61 and −0.87, of opposite sign, so the two contributions there have the same sign and do not cancel; the receptance dips to a shallow trough near 11 Hz without a true notch, and the phase keeps going. By 40 Hz it has lagged a full turn. The swap is exact, and it still does not make a transfer look like a driving point. Swapping changes which point is pushed, not whether the push and the reading are at the same place.

The hammer maps the mode only if the sensor can see it

Reciprocity is the reason a large structure can be tested with one accelerometer and a hammer, and it is also the reason a badly placed accelerometer ruins the whole test.

The hammer maps the mode only if the sensor can see it. A sensor fixed at one point of a 12 m simply supported beam and a hammer moved through points 0.50 m apart, read as the imaginary part of the receptance at the second natural frequency, 15.9 Hz. With the sensor 3.0 m along, where the mode's ordinate is 1.00, the readings run from -0.443 to 0.444 mm/kN; with the sensor 6.0 m along, where the mode's ordinate is 0.00, every reading is zero to three decimal places. The readings trace the mode shape multiplied by the sensor's own ordinate, which is why a sensor on a node sees nothing of that mode wherever the hammer lands.
Fig. 4 A sensor fixed at one point of the beam and a hammer moved through points 0.50 m apart, read as the imaginary part of the receptance at the second natural frequency, 15.9 Hz. With the sensor 3.0 m along, where the mode’s ordinate is 1.00, the readings run from −0.443 to 0.444 mm/kN; with the sensor 6.0 m along, where the mode’s ordinate is 0.00, every reading is zero to three decimal places.

In a roving-hammer test the accelerometer stays put and the hammer moves. Each strike gives one transfer receptance, from the hammer point to the sensor. Reciprocity says each of those equals the receptance from the sensor point to the hammer point, so the set of strikes is the same as a single force at the sensor with a reading taken everywhere: one column of the beam’s receptance matrix, which is exactly what is needed to see the mode shapes.

At a natural frequency, with light damping, the mode at resonance dominates and its contribution is almost purely imaginary. The imaginary part of each reading is then proportional to the mode’s ordinate at the hammer times its ordinate at the sensor. With the sensor at 3 m, the readings trace the second mode’s shape, a full sine wave, scaled by the sensor’s own ordinate of 1.00.

With the sensor at mid-span the scale factor is the second mode’s ordinate at mid-span, which is zero. Every reading is zero. The mode does not appear anywhere in the test, whatever the hammer does, and the swap is why: a sensor on a node cannot see a mode, and by reciprocity that is the same statement as a force at that node being unable to excite it, from any hammer position at all. A test campaign that put its reference accelerometer at mid-span — the natural place to put it, where the first mode is largest — would report a beam with no second mode. A mode shape notices some changes and not others, and the same is true of the instrument reading it. The practical remedy is a second reference, placed where the first one’s blind modes are large.

A dashpot at one point, and the swap still exact

The modal argument proved reciprocity for a beam whose damping is proportional to its mass and stiffness. That is a convenience, and it is not the reason.

A dashpot at one point, and the swap still exact. The transfer receptances of a 12 m simply supported beam, A 3.0 m and B 8.0 m from one end, with a dashpot of 20 kN·s/m from the point 2.0 m along it to the ground, beside the same transfer with no dashpot. The dashpot is not proportional to the mass or the stiffness, so the beam's modes are no longer real shapes, and the transfer's first peak falls to 1.73 mm/kN. The two directions still differ by less than a billionth of their size, because the dashpot's matrix is symmetric.
Fig. 5 The transfer receptances of the beam with a dashpot of 20 kN·s/m from the point 2.0 m along it to the ground, beside the same transfer with no dashpot. The dashpot is not proportional to the mass or the stiffness, so the beam’s modes are no longer real shapes, and the transfer’s first peak falls to 1.73 mm/kN. The two directions still differ by less than a billionth of their size.

A concentrated dashpot is the ordinary case for anything real that damps a structure: a viscous damper at a bearing, a hydraulic buffer, the soil under one foundation. It damps the modes in proportion to their motion at one point, so it damps them unequally and also couples them, and the beam’s natural modes become complex — each point reaching its maximum at a slightly different moment of the cycle, with a node that wanders. There is no longer a sum of real shapes to write down, and the product-of-ordinates argument has nothing to apply to.

The coupling is visible in the figure: the third mode, which the transfer did not contain while B sat on its node, comes back as a small kink at 36 Hz, because the dashpot hands some of the third mode’s motion to modes that B can feel. Yet the transfer receptances still agree to less than a billionth. The reason is the matrix, not the modes. The receptance at a frequency is the inverse of the beam’s dynamic stiffness, K−ω2M+iωCK - \omega^2 M + i\omega C, and the inverse of a symmetric matrix is symmetric. The stiffness matrix is symmetric because Maxwell’s static theorem says the flexibility is. The mass matrix is symmetric because a mass pushes only on itself. And the damping matrix is symmetric because a dashpot between two points pushes on each with a force set by their relative velocity, equal and opposite, the same law in both directions — and a dashpot to the ground is a dashpot to a point that does not move.

So the general statement is Betti’s in dynamic form. Two harmonic loadings at the same frequency, each doing work through the other’s displacements, do equal work, for any structure whose every internal force is a symmetric function of the motion. Inertia, stiffness and passive damping all qualify. What would not is any force that depends on motion at one point and acts at another without acting back.

A loop from a sensor to an actuator parts the two directions

That kind of force is exactly what a feedback controller is.

A loop from a sensor to an actuator parts the two directions. A 12 m simply supported beam, A 3.0 m and B 8.0 m from one end, with a sensor at A reading velocity and an actuator at B pushing against it at 20 kN·s/m, between 25 and 40 Hz. Force at B read at A and force at A read at B are no longer the same curve: they differ most at 35.9 Hz, where one is 1.27 times the other — 0.00148 against 0.00116 mm/kN. Without the loop both directions are the dotted curve.
Fig. 6 The beam with a sensor at A reading velocity and an actuator at B pushing against it at 20 kN·s/m, between 25 and 40 Hz. Force at B read at A and force at A read at B are no longer the same curve: they differ most at 35.9 Hz, where one is 1.27 times the other, 0.00148 against 0.00116 mm/kN. Without the loop both directions are the dotted curve.

An actuator at B driven by a velocity sensor at A applies a force at B proportional to the velocity at A, with nothing acting at A in return. In the damping matrix it is a single entry, in the row for B and the column for A, and the matrix stops being symmetric. The receptance is no longer the inverse of a symmetric matrix and there is no theorem left.

The two directions part most at 35.9 Hz, the third natural frequency, by a factor of 1.27, and the mechanism is the node. A force at B cannot excite the third mode, because B sits on its node, so with the force at B the sensor at A sees no third mode and the loop has nothing of it to feed back. A force at A excites the third mode strongly. The sensor at A sees it, the actuator at B pushes at its frequency, and although that push cannot excite the third mode either, it moves B through the other modes. The reading at B therefore carries a third-mode resonance that the reverse reading does not. The loop has carried a mode across a node in one direction only.

What is more surprising is how little the loop does elsewhere. Near the first two resonances the two directions agree to well under one per cent. The algebra for a single added entry is exact and short: the loop changes the two transfers by amounts whose difference is proportional to the gain times HAB2−HAAHBBH_{AB}^2 - H_{AA}H_{BB}, the receptances of the beam without the loop. Near an isolated resonance one mode dominates every receptance, each of them is that mode’s product of ordinates over the same denominator, and the difference is ϕ(A)2ϕ(B)2−ϕ(A)2ϕ(B)2\phi(A)^2\phi(B)^2 - \phi(A)^2\phi(B)^2, which is nothing. A single mode is reciprocal however it is fed, because one mode’s receptance matrix is the outer product of one shape with itself. The loop breaks the swap only where two or more modes share the response — between resonances, or at a mode one point cannot see.

That is a useful thing for anybody reading a modal test of a structure with active control. A reciprocity check made at the resonance peaks will pass. The asymmetry is in the valleys.

The loop that damps one mode feeds the next

A feedback loop is installed to add damping, and the same products of ordinates that decided the swap decide which modes it damps.

The loop that damps one mode feeds the next. The largest response at A to a force at A, in the first two modes of a 12 m simply supported beam, A 3.0 m and B 8.0 m from one end, as the gain of a loop from a velocity sensor at A to an actuator at B rises from nothing to 24 kN·s/m. The first mode's peak falls from 2.22 to 0.84 mm/kN, because its ordinates at A and B have the same sign; the second's rises from 0.44 to 5.60, because they do not. On a one-mode estimate the loop cancels the second mode's 1.25 per cent damping at about 26 kN·s/m, and above that the beam drives itself.
Fig. 7 The largest response at A to a force at A, in the first two modes, as the gain of a loop from a velocity sensor at A to an actuator at B rises from nothing to 24 kN·s/m. The first mode’s peak falls from 2.22 to 0.84 mm/kN, because its ordinates at A and B have the same sign; the second’s rises from 0.44 to 5.60, because they do not. On a one-mode estimate the loop cancels the second mode’s 1.25 per cent damping at about 26 kN·s/m.

The loop adds to each mode a damping proportional to the gain times the mode’s ordinate at the sensor times its ordinate at the actuator. For the first mode both ordinates are positive, 0.71 and 0.87, and the loop damps it: the peak falls by more than half over the range drawn. For the second mode the product is −0.87, and the loop adds negative damping — it pushes in phase with the velocity rather than against it. The second mode’s peak climbs slowly and then steeply, and on the one-mode estimate its own 1.25 per cent of damping is gone at about 26 kN·s/m. Above that gain the beam drives its own second mode from the energy the actuator supplies, and the receptance at that frequency stops meaning anything.

This is the classical hazard of a non-collocated loop, with the sensor and the actuator at different points, and it is the same fact as the broken swap. Put the actuator at A beside the sensor — a collocated pair — and the added entry sits on the diagonal of the damping matrix, which stays symmetric, so the swap survives. The product of ordinates becomes a square, ϕk(A)2\phi_k(A)^2, which cannot be negative, so every mode is damped and none fed. A collocated velocity loop with no delay is a dashpot in every respect that matters, and reciprocity and unconditional stability are the same symmetry seen twice. What can still undo it is time: an actuator that arrives late turns a damping force into a stiffness and eventually into a driving one, and a control law tuned for one mode can throw away what a passive device was doing for the others.

What the twenty-three masses leave out

The beam is a lumped model. Twenty-three masses on a 12 m Euler–Bernoulli beam reproduce the continuous beam’s first three frequencies to within about a per cent, and its higher ones increasingly less well. Nothing in the argument depends on that, because the symmetry holds for any number of masses.

The damping is linear viscous. Real structural damping is partly friction at joints, which depends on amplitude and on the sign of the velocity and is not a symmetric linear function of anything. A structure whose damping comes mainly from slipping bolts is not exactly reciprocal, and the asymmetry measured between swapped readings is one of the few direct measurements of how nonlinear it is. The three hypotheses the static theorem needs — linearity, elasticity, small displacements — carry over, and a slack bracing member or a diagonal that goes slack breaks the dynamic swap exactly as it breaks the static one.

The loop has no delay and no dynamics of its own. A real actuator has a bandwidth, a sensor has a filter, and both shift the phase of the force; the products of ordinates still decide which modes are fed, but the gain at which the second mode is lost would move.

And several other forces are not symmetric and were not drawn. A rotating machine on a floor exerts gyroscopic forces that couple two directions antisymmetrically. A deck in wind feels aerodynamic forces that depend on its own motion and act elsewhere. Water flowing past a pier does the same. Each is an engineered or natural feedback loop, each breaks the swap, and each is a member of the family whose extreme is a structure that supplies its own excitation from a steady flow.

Still open: the swap with a moving load

The theorem compares two loadings at fixed points. A vehicle crossing a bridge is a load whose point of application moves, and it couples the bridge’s response at the point it has reached to the force it applies there — through the vehicle’s own suspension, a mass and spring travelling with it. The bridge alone is reciprocal; the bridge with a vehicle on it is a different structure at every instant, and whether a moving-load influence line can still be read off a single dynamic deflected shape, in the way a static one can, is a question the fixed-point argument here does not reach.

Helmholtz stated a reciprocal principle for sound in 1860, and Rayleigh generalised it to every vibrating system with damping in 1873, nine years after Maxwell’s static theorem, and carried it into The Theory of Sound. It entered structural testing a century later, when the hammer and the accelerometer made it cheaper to strike a structure in many places than to instrument it in many places — and the theorem that licensed the swap turned out to have been sitting in a treatise about acoustics the whole time.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

The objects this essay names

Each one links to every other essay that touches it.

Active controlCollocationDampingFeedbackFlexibilityFrequency responseModal analysisMode shapeNatural frequencyReciprocityResonanceSuperposition