Structural form

The girder sized member by member

A Vierendeel girder's posts can be sized to the stress ranges a crossing load gives them, and the earlier essay found that this keeps the girder's fatigue life for a tenth less steel. With the chords counted too — their axial force and their bending together — the girder's worst member is not a post but a middle chord. Sizing every member to that one range takes a quarter of the steel out and keeps the life; the posts barely move when the chords are resized, and sizing the two in turn settles in four passes. Sized for strength instead, the same girder uses more steel and lives a third as long, and sized to a range a fifth below the worst it is lighter than the uniform girder and lives twice as long.

Assumes The truss with no diagonals, The load that never came near failing anything and The panel that gravity leaves empty.

The post sized by what it must survive took a Vierendeel girder crossed by a moving load and resized its posts one by one. Every post of a uniform girder carries nearly the same range of corner moment as the load passes, though their peaks differ by a factor of two, so sizing each post to its peak lightens the middle posts most and doubles their stress range: the steel saving of 27 per cent is paid for with a fatigue life cut from 1.49 million crossings to 209 thousand. Sizing each post to its range instead kept the uniform girder’s life for 11 to 12 per cent less steel. The chords were left alone throughout, one section from end to end.

That essay ended by noting what this leaves undone. A girder whose posts have been resized shares its panel shear differently between chords and posts, and the chords have peaks and ranges of their own, set panel by panel by the crossing load. Whether sizing the chords to their own ranges concentrates the moment back into the posts that have just been settled; whether the two sizings converge to one girder or chase one another; and whether a girder sized member by member for fatigue ends up much lighter than one sized for strength and then checked — that is what sizing every member asks.

Every member its own section

The girder is the earlier essay’s without its haunches: six panels of 2 m, 1.5 m deep, every member to begin with of one section — a second moment of 117 × 10⁶ mm⁴, an area of 6,840 mm² and an elastic modulus of 780 × 10³ mm³. A load of 100 kN crosses the top chord, stopping at every node, and the frame is solved at each stop. Every post and every panel’s pair of chords may be given its own section, a multiple ff of the uniform one, with its second moment, area and modulus all scaled by ff, as a section of the same depth with heavier or lighter flanges is.

What is new is the chords’ stress. A post’s stress is its corner moment over its modulus, as before. A chord also carries the girder’s overall bending as an axial force — the top chord in compression, the bottom in tension, each about the girder’s moment at that panel over its depth — and its own panel shear as bending, so its extreme fibre at a panel end sees ∣N∣/A+∣M∣/W|N|/A + |M|/W, with the sign that end’s moment gives it. The stress range at each panel end over the crossing is what a detail there is checked against, and each panel’s chords are sized to the worst of their four ends. The fatigue life is Eurocode 3’s line on the slope of three — the line the load that never came near failing anything draws for every welded detail — for a detail category of 71, with its constant-amplitude limit below which a range does no damage.

The uniform girder’s ranges

Every member's stress range as the load crosses the uniform girder. The stress range in each post (at its worse corner) and in each panel's chords (at the worst of their four ends, axial force and moment together) of a Vierendeel girder of six 2 m panels, 1.5 m deep, every member at first of one section (I = 117 × 10⁶ mm⁴), crossed by a 100 kN load, along the span. The posts range 50, 78, 76, 76, 76, 78, 50 N/mm² from end to end; the chords 71, 92, 103, 103, 92, 71. The worst member is a middle chord at 102.8, the worst post 78.3.
Fig. 1 The stress range in each post, at its worse corner, and in each panel’s chords, at the worst of their four ends with axial force and moment together, of the uniform girder as the 100 kN load crosses it. The posts range 50, 78, 76, 76, 76, 78 and 50 N/mm² from end to end; the chords 71, 92, 103, 103, 92 and 71. The worst member is a middle chord at 102.8, the worst post 78.3.

The posts’ ranges are the earlier essay’s pattern: the end posts least, every other post nearly the same, because each post’s range is the difference between the load being on one side of it and on the other, and that difference is about the panel shear times the panel length whatever the post’s place. The chords’ pattern is different, rising toward mid-span. A chord at mid-span has little panel shear of its own when the load is far away and a great deal of axial force when the load is near, because the girder’s moment is largest there; its range is the sum of both. The end panels’ chords range less, 71 N/mm², because the girder’s moment near the supports is small.

So the uniform girder’s governing member is a middle chord, at 103 N/mm², not a post. The earlier essay’s uniform life of 1.49 million crossings was the posts’ alone; with the chords counted the girder lives 660 thousand. That changes the problem the sizing has to solve. Making every member as durable as the worst one is now a matter of bringing everything else up to the middle chords’ range, which lightens almost every member, rather than of protecting the posts.

A middle chord’s range, by hand

The middle chord’s 103 N/mm² can be had from statics in a few lines, and doing it shows why the chords were the members the earlier essay could not leave out. With the load at mid-span the girder’s moment there is PL/4=100×12/4=300PL/4 = 100 \times 12/4 = 300 kN·m, carried by the two chords as a couple 1.5 m apart, so each chord carries about 200 kN: 29 N/mm² on its 6,840 mm². That is the axial part, and it comes and goes as the load arrives and leaves, a range of about 29.

The bending part is the panel’s shear. A Vierendeel carries a panel’s shear by bending both chords in double curvature, as the frame is a girder stood on end drew it, each chord taking half the shear with a moment of Vs/4Vs/4 at each end — for a mid-span panel with the load just to one side, about 50×2/4=2550 \times 2/4 = 25 kN·m, or 32 N/mm² on the chord’s modulus. As the load crosses from one side of the panel to the other the shear reverses, so the bending stress swings from +32 to −32, a range of 64. Axial and bending together range about 93 N/mm² against the frame’s 103: the difference is that the extreme fibre sees both at once, and the moment and axial force peak at nearby but not identical load positions.

The posts, by the same arithmetic, carry the sum of the chord moments at their joints, which for an interior post is about Vs/2Vs/2 divided between the post’s two corners and so ranges like the chords’ bending alone, without the axial part. That is why the posts range 76 and the middle chords 103: the chords carry the girder’s overall bending on top of their share of the panel’s, and the posts do not. An essay that sized the posts and left the chords at one section was sizing the members that did not govern.

Sizing the chords hardly moves the posts

Sizing the chords hardly moves the posts. Each member's section, as a multiple of the uniform girder's, for a Vierendeel girder of six 2 m panels, 1.5 m deep, every member at first of one section (I = 117 × 10⁶ mm⁴), crossed by a 100 kN load: the posts sized alone to the girder's worst range, 102.8 N/mm², and every post and chord sized together. Posts alone: 0.44, 0.75, 0.68, 0.68, 0.68, 0.75, 0.44. Every member: posts 0.45, 0.77, 0.69, 0.68, 0.69, 0.77, 0.45; chords 0.72, 0.89, 0.99, 0.99, 0.89, 0.72.
Fig. 2 Each member’s section as a multiple of the uniform girder’s: the posts sized alone to the girder’s worst range, 102.8 N/mm², and every post and chord sized together. Posts alone: 0.44, 0.75, 0.68, 0.68, 0.68, 0.75 and 0.44. Every member: posts 0.45, 0.77, 0.69, 0.68, 0.69, 0.77 and 0.45; chords 0.72, 0.89, 0.99, 0.99, 0.89 and 0.72.

Sized to the girder’s worst range, the posts lose about a third of their section — the end posts more, since they ranged least — and the chords, sized too, run from 0.72 at the ends to 0.99 at mid-span, where the middle chords are already at the target and stay. The question was whether resizing the chords would send moment back into the posts. It barely does: with the chords sized as well, the posts’ sizes move by at most 0.02.

The reason is that the frame’s sharing is set by ratios, and the sizing changes both members at a joint by similar factors. A Vierendeel carries its panel shear by bending the chords, and the moments at a joint balance: the post’s corner moment is the sum of the two chord moments meeting it. The share each member takes depends on the relative stiffnesses at the joint, and lightening a chord and its neighbouring post together moves that share less than lightening either alone. The posts and chords near the ends are lightened most and the middle chords least, so the joints at mid-span, where the stiffness ratio does change, are joints whose posts were already near their final size.

Sized in turn, they settle at once

Posts and chords sized in turn settle at once. The steel in a Vierendeel girder of six 2 m panels, 1.5 m deep, every member at first of one section (I = 117 × 10⁶ mm⁴), crossed by a 100 kN load, in multiples of one member, and its worst stress range, pass by pass, with the posts and the chords sized in turn, each to the uniform girder's worst range with the other held. From 13.00 the steel goes to 10.72, 9.89, 9.73, 9.75, 9.72 and stays at 9.72, the same as sizing everything at once (9.72); the worst range stays within 0.9 N/mm² of 102.8 throughout.
Fig. 3 The steel in the girder, in multiples of one member, and its worst stress range, pass by pass, with the posts and the chords sized in turn, each to the uniform girder’s worst range with the other held. From 13.00 the steel goes to 10.72, 9.89, 9.73, 9.75 and 9.72 and stays there, the same as sizing everything at once; the worst range stays within 0.9 N/mm² of 102.8 throughout.

The figure plays out the two designers of the earlier essay’s question. One sizes the posts to the frame’s moments with the chords as they are; the other then sizes the chords with the posts as the first left them; the drawing goes back and forth. The first pass, posts only, takes the girder from 13.00 members of steel to 10.72; the second, chords, to 9.89; by the fourth the change is two hundredths of a member, and the girder settles at 9.72 — exactly where sizing everything together lands. The two sizings do not chase one another; they converge in four passes to one girder. The worst range never strays more than 0.9 N/mm² from its target in the process, because each resizing is to a range and the frame’s redistribution after it is small.

That is a design fact as much as a mechanical one. A fixed-point iteration of this kind can oscillate when each member’s demand depends strongly on the others’ sizes, which is the situation in an indeterminate frame where stiffness attracts moment. In a Vierendeel crossed by a moving load the attraction is weak, because a member’s range is set mostly by the panel shear and the girder’s moment, which the members’ sizes do not change, and only slightly by the shares.

What each way of sizing costs

The steel each way of sizing the girder costs. The steel in a Vierendeel girder of six 2 m panels, 1.5 m deep, every member at first of one section (I = 117 × 10⁶ mm⁴), crossed by a 100 kN load, in multiples of one uniform member, posts and chords together: uniform 13.00; posts to ranges 10.42; chords to ranges 12.20; all to ranges 9.72; all to peaks 10.74. Sized to ranges, every member sized is brought to the uniform girder's worst range; sized to peaks, to its worst peak stress.
Fig. 4 The steel in the girder, in multiples of one uniform member, posts and chords together: uniform 13.00; posts sized to ranges 10.42; chords sized to ranges 12.20; every member to ranges 9.72; every member to peaks 10.74. Sized to ranges, every member sized is brought to the uniform girder’s worst range; sized to peaks, to its worst peak stress.

Each sizing is drawn as its total steel with the share in the posts. Posts alone bring the girder to 10.42 members, chords alone to 12.20, and both to 9.72 — a quarter less than the uniform girder, almost all of it from the posts and the end panels’ chords. The posts take most of the saving because their ranges were furthest below the governing chord’s.

The fifth bar is the girder sized for strength: every member brought to the uniform girder’s worst peak stress, the check a static design makes, and then left for a fatigue check to accept or not. It costs 10.74 members, more than sizing to ranges, which reverses the expectation that a fatigue limit is the more demanding one. It does so because peaks and ranges are not proportional along the girder. The middle posts have large ranges and small peaks — the load passes over them from one side to the other and reverses their corner moment — so a sizing to peaks lightens them to 0.40 of their section, while the end chords have peaks near their ranges and keep more steel than a range sizing would give them.

And the crossings each one survives

And the crossings each girder survives. The fatigue life of a Vierendeel girder of six 2 m panels, 1.5 m deep, every member at first of one section (I = 117 × 10⁶ mm⁴), crossed by a 100 kN load, the shortest of every post's and every chord's, at a detail category of 71: uniform 660 thousand; posts to ranges 659 thousand; chords to ranges 660 thousand; all to ranges 660 thousand; all to peaks 209 thousand crossings.
Fig. 5 The fatigue life of the girder, the shortest of every post’s and every chord’s, at a detail category of 71: uniform 660 thousand crossings; posts sized to ranges 659 thousand; chords sized to ranges 660 thousand; every member to ranges 660 thousand; every member to peaks 209 thousand.

The four range sizings keep the uniform girder’s life to within a thousand crossings, as they were built to: every member brought to the governing range has the governing life. The strength sizing lives 209 thousand crossings, under a third — the earlier essay’s figure, because its governing member is again a middle post lightened to 0.40 and ranging 151 N/mm². Sized member by member for fatigue the girder is lighter than sized for strength, and lives three times as long. A girder designed for peaks and then checked for fatigue would fail its check at the middle posts and have to be thickened there, and the thickened girder would be heavier still than the one sized to ranges in the first place.

The earlier essay found the same reversal for the posts alone. Counting the chords does not change it; it adds a quarter of the girder’s steel to the members that can be made lighter, since the end panels’ chords range only 71 N/mm² against the governing 103.

Every member at one range

Every member at one range: the steel it costs and the life it buys. Every post and chord of a Vierendeel girder of six 2 m panels, 1.5 m deep, every member at first of one section (I = 117 × 10⁶ mm⁴), crossed by a 100 kN load sized to one stress range, against that range: the steel, in uniform members, and the life in hundreds of thousands of crossings. At 82 N/mm², 12.14 and 1.29 million; at the uniform girder's worst, 103, 9.72 and 660 thousand; at 144, 6.94 and 240 thousand. Sized to peaks the girder is 10.74 members and lives 209 thousand.
Fig. 6 Every post and chord of the girder sized to one stress range, against that range: the steel in uniform members and the life in hundreds of thousands of crossings. At 82 N/mm², 12.14 and 1.29 million; at the uniform girder’s worst, 103, 9.72 and 660 thousand; at 144, 6.94 and 240 thousand. Sized to peaks the girder is 10.74 members and lives 209 thousand.

The target need not be the uniform girder’s worst range. Every member can be sized to any range, and the figure trades steel against life along that one choice. At 144 N/mm² the girder is 6.94 members and lives 240 thousand crossings — about the strength sizing’s life for two thirds of its steel. At 82 N/mm² it is 12.14 members and lives 1.29 million — lighter than the uniform girder and twice as long-lived at once. The uniform girder is not on the trade-off at all: every range between about 80 and 103 N/mm² gives a girder that is both lighter and longer-lived than one section from end to end.

That makes the uniform girder the thing that is hard to justify, not the sized one. A girder of one section puts most of its steel where it is not needed, in the posts and the end chords whose ranges were far below the middle chords’, and it is the middle chords alone that set its life. Fatigue sizing is just the act of moving that steel to where the ranges are.

The life of a sized girder, by hand

The convergence and the saving can both be had from the uniform girder’s ranges alone. A member’s stress range is its moment range over its modulus, and if resizing it changed nothing else its new range would be its old one over its scale ff; to bring it to a target Δσ∗\Delta\sigma^* it needs f=Δσ/Δσ∗f = \Delta\sigma/\Delta\sigma^*. Summing that over the uniform girder’s ranges with Δσ∗=103\Delta\sigma^* = 103 gives the posts (50+78+76+76+76+78+50)/103=4.71(50 + 78 + 76 + 76 + 76 + 78 + 50)/103 = 4.71 and the chords (71+92+103+103+92+71)/103=5.17(71 + 92 + 103 + 103 + 92 + 71)/103 = 5.17, a girder of 9.89 members — within two per cent of the 9.72 the frame’s own iteration reaches. The frame’s redistribution, the thing the earlier question feared, is worth that two per cent, and it lightens the girder rather than thickening it.

The same sum says what the target buys. Steel goes as one over the target, so halving the target doubles the steel; life goes as the target to the minus third power, so halving it multiplies the life by eight. Between 82 and 144 N/mm² the figure’s steel falls by 43 per cent and its life by 81, which is the cube against the line.

What the frame leaves out

The girder’s sections are scaled as wholes: a member twice as heavy has twice the second moment and twice the modulus, which is true of a section deepened by heavier flanges at a fixed depth and not of one made deeper. Real sections come in steps, so the smooth scales of the figures would be rounded up to the next available size, and a girder of six panels has few enough members that the rounding is a few per cent of its steel. Every member’s detail is one category, 71, at every end, where a real Vierendeel’s post-to-chord corners are the worse details and its chord splices may be better; the earlier essays’ corner that counts its crossings and its haunches are the place where that distinction was drawn.

The load is a single 100 kN point crossing the top chord, so every member’s range comes from one vehicle passing once. A real deck carries vehicles of many weights, and a member whose range falls below the constant-amplitude limit for the lighter ones does no damage from them, which favours members sized to a lower range more than the slope of three admits. And the girder carries only the crossing load, with no dead load: dead load adds to every peak and to no range, so it would make the strength sizing heavier still and leave the range sizing as it is.

The panel shear decides, and the sizes follow

The reason fatigue sizing is so well-behaved here is that in a Vierendeel the demand on each member is set almost entirely by statics: the panel shear, which the moving load fixes, and the girder’s moment, which it also fixes. Neither depends on the members’ sizes. What the sizes change is only how each joint divides a moment it must carry anyway, and the load that visits every panel found how little that division varies along a girder. An indeterminate frame whose members attract moment in proportion to their stiffness would not converge so quickly; a determinate truss would converge in one pass, because its member forces do not depend on its sizes at all. The Vierendeel sits close to the truss, which is the sense in which the truss with no diagonals is still a truss.

Still open: the girder sized for a spectrum of vehicles

Every member here is sized to the range one vehicle gives it, and every member then has one life. A deck’s traffic is a spectrum, and Eurocode 3’s slope changes from three to five below the constant-amplitude limit, the knee the cycles that do not count is about: a member sized so that the heavy vehicles range it just above the limit does nearly all its damage from them and almost none from the many lighter ones, while a member sized more heavily may put most vehicles below the limit entirely. Sizing to a spectrum is therefore not sizing to one range scaled; it is a sizing whose target differs member by member according to how its own spectrum sits against the knee. Whether a girder sized to its spectrum ends up lighter than one sized to its heaviest vehicle, and whether the end posts, whose ranges are smallest, become the members that can be lightened most of all because all their traffic falls under the knee, is what the spectrum would ask of the heavy chord the posts will not let work.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

The objects this essay names

Each one links to every other essay that touches it.