Dynamics

The bearings changed in opposite pairs

A building on friction pendulums does not twist because every bearing's friction is its load times one coefficient, so the friction's resultant passes through the mass. Replace one bearing with a new one and that stops being exactly true. One bearing does almost nothing: about one per cent at a corner. The order of a whole programme does more. Worked from one end of the plan to the other, the halfway state moves the friction's centre 2.5 m and the corner bearings travel 8 per cent further than the mass; worked in pairs opposite each other through the centre, the plan never twists by more than two per cent and is straight again after every second bearing.

Assumes Made weaker on purpose, The force that is whatever it needs to be and The corner that moves most.

The bearing that does not know what it carries put a 30 by 18 m rigid floor on twelve friction pendulums and found the property that makes them unusual. A pendulum’s stiffness is the weight on it over the radius of its dish, so the centre of the plan’s stiffness stands exactly under its centre of mass wherever the mass is put, and the building does not twist. The friction obeys the same rule: each bearing resists sliding with its own load times one coefficient, so the friction’s resultant also passes through the mass. A building on elastomers with its mass 3.6 m off centre moved its corner bearings 17 per cent further than its mass — the amplification the corner that moves most found in any plan whose stiffness and mass do not share a centre — and on pendulums, not at all.

The essay found one way to break that, and it was the friction. If the coefficient varies from bearing to bearing, the friction’s resultant no longer passes through the mass and a torque appears whatever the mass does — 4 per cent for a linear variation of ±20 per cent across the plan, 8 per cent for ±40. It ended on a variation that is not linear and that every isolated building will one day have: a single bearing replaced. A new slider beside eleven that have run for thirty years has a fresh sliding surface, and its coefficient may be lower than the old ones’, where theirs has risen with wear and contamination, or higher, where a new composite liner breaks away harder. Whether one replacement twists the building, where in the plan it matters most, and in what order a whole set should be changed, were left open.

The answers come out of one point on the plan, which neither of the earlier essays needed to name.

A centre for the friction

When a rigid plate slides on its bearings without turning, every bearing moves with the same velocity and every friction force points the same way, opposite to it. Bearing ii pushes back with μiWi\mu_i W_i, its coefficient times its load. Forces that are parallel have a resultant whose magnitude is their sum and whose line passes through their weighted centre,

rf=∑μiWi ri∑μiWi,\mathbf{r}_f = \frac{\sum \mu_i W_i\, \mathbf{r}_i}{\sum \mu_i W_i},

the friction centre. When every μi\mu_i is the same it cancels, and the friction centre is ∑Wiri/∑Wi\sum W_i \mathbf{r}_i / \sum W_i, which is the centre of mass by statics: the loads on the bearings are whatever puts their resultant under the mass. That is the whole of the pendulum’s refusal to twist under friction, stated as a fact about a centroid.

Change one coefficient and the friction centre moves, by the bearing’s share of the total friction times its distance from the mass. One of twelve equally loaded bearings, its friction cut to 0.6 of the others’, at a corner 15 m along and 9 m across from the centre: the total friction falls to 11.6/1211.6/12 of what it was, and the centre moves 0.4/11.6×15=0.520.4/11.6 \times 15 = 0.52 m along the plan and 0.4/11.6×9=0.310.4/11.6 \times 9 = 0.31 m across it. That is the eccentricity a replacement brings, and like a mass eccentricity it acts only through the component perpendicular to the ground’s motion.

The calculation that follows takes the plan of the earlier essay, isolated at the long period made weaker on purpose priced — twelve bearings on a 4 × 3 grid, a 3 s dish, a coefficient of 0.05 — gives each bearing a coefficient of its own, and drives the rigid plate in its three freedoms through six pairs of synthetic records at 3.5 m/s², shaking both ways at once. Every friction force follows its own bearing’s velocity, which on a twisting plate is not quite the plate’s. Each bearing is a friction device of the kind the force that is capped on purpose described, its slip load its coefficient times its weight, and twelve such caps in parallel share a moving load by where they stand. With every coefficient equal it reproduces the earlier essay’s plate to the last digit.

One bearing among twelve

One bearing replaced among twelve. The largest bearing travel over the travel at the mass, the mean of six records shaken both ways, with one bearing given a friction of a multiple of the others' 0.05. At 0.60 of the others: a corner 1.011, an inner bearing on a long edge 1.009, the middle of a short edge 1.010, an inner bearing 1.003. At 2.5 times, 1.046, 1.036, 1.042, 1.013.
Fig. 1 The largest bearing travel over the travel at the mass with one bearing given a different friction from the other eleven, at four places in the plan, the mean of six records shaken both ways. At 0.6 of the others’ friction, 1.011 at a corner and 1.003 inside the plan; at 2.5 times, 1.046 and 1.013.

A single replacement is a small thing. With the new bearing’s friction at 0.6 of the others’ the largest bearing travel exceeds the travel at the mass by 1.1 per cent if it is at a corner, 0.9 per cent on a long edge, 1.0 per cent at the middle of a short edge and 0.3 per cent inside the plan. At 1.6 times the others’ it is 1.7 per cent at a corner. Only a bearing two and a half times as rough as its neighbours, which is more than wear or a new liner usually brings, reaches 4.6 per cent.

The order of the places is the order of their lever arms. Shaken both ways, a corner bearing’s friction acts 15 m from the mass in one direction and 9 m in the other, and it is the worst place for a replacement to be. The middle of a short edge is almost as bad, because it has the longest lever of all for shaking along the plan’s width. An inner bearing at 5 m along and on the centre line has almost no lever and almost no effect. Asked of a single bearing, the question has a modest answer: a replaced corner bearing does twist the plan, by under 3 mm at the corners of a building whose mass travels 240 mm, and no dish was sized to 3 mm.

The path of the friction centre

Where the friction centre goes as the bearings are changed. The friction centre — the point the friction forces' resultant passes through when the plate slides without turning — after each bearing of twelve is replaced by one with 0.60 of the others' friction, in four orders, the mass at the plan's centre. End to end it walks 2.50 m from the mass, side by side 1.72, corners first 1.07; in opposite pairs 0.71, and back to the mass after every pair.
Fig. 2 The friction centre after each of twelve bearings is replaced by one with 0.6 of the old ones’ friction, in four orders, the mass at the origin. End to end, through each short row of three in turn, it walks 2.50 m along the plan; side by side, through each long row of four, 1.72 m across it; corners first 1.07 m; in opposite pairs never more than 0.71 m, and back to the origin after every pair.

Bearings are not replaced all at once. A building in use has its bearings changed one or two at a time, each lifted on jacks off its neighbours, over weeks or months — and between visits the building stands on a set that is part old and part new. The single-bearing answer describes the first visit. Every later visit starts from a friction centre that the earlier ones have already moved, and the order of the visits decides where it goes.

Four orders tell the story. Working from one end of the plan to the other, a short row of three at a time, moves the friction centre steadily away from the mass until half the plan is new: then six bearings on one side have 0.6 of the other six’s friction and the centre stands 2.5 m from the mass, at (0.6×−10+1×10)/1.6(0.6 \times -10 + 1 \times 10)/1.6. It comes back only as the second half is done. Working side by side along the long rows takes it 1.72 m across the plan. Corners first takes it a metre at most. Replacing bearings in pairs that stand opposite each other through the centre of the plan — a corner and the corner diagonally across from it, then the next pair — takes it no further than the single bearing did, 0.71 m at worst, and brings it back to the mass after every pair.

The reason is in the formula. Two bearings at r\mathbf{r} and −r-\mathbf{r}, equally loaded and changed together by the same amount, add nothing to ∑μiWiri\sum \mu_i W_i \mathbf{r}_i, because their contributions cancel. Every complete pair leaves the friction centre where it found it. The building twists only during the visits between the first and second bearing of a pair, and then only by the single bearing’s amount.

Four orders, step by step

The twist through four orders of replacing twelve bearings. The largest bearing travel over the travel at the mass after each bearing is replaced, the new ones at 0.60 of the old ones' friction, the mean of six records shaken both ways. End to end the worst step is 1.080, halfway; side by side 1.050; corners first 1.029; in opposite pairs 1.023, falling back to one after each pair.
Fig. 3 The largest bearing travel over the travel at the mass after each replacement, the new bearings at 0.6 of the old ones’ friction, the mean of six records shaken both ways. End to end, 1.080 at the halfway step; side by side, 1.050; corners first, 1.029; opposite pairs, 1.023, and 1.000 after each completed pair.

The travel follows the friction centre. End to end, the ratio of the largest bearing travel to the travel at the mass climbs through the first half to 1.080 at six replacements and stays near it to the ninth: the corner bearings at the slippery end travel 8 per cent further than the mass. That is the twist the earlier essay found for a linear gradient of ±40 per cent across the whole plan — more than a batch of bearings delivered together would ever be allowed to scatter by, created here by a maintenance programme in which no bearing is out of tolerance and every one is either old or new. Side by side reaches 1.050. Corners first reaches 1.029. Opposite pairs reach 1.023, during the visit that has done one bearing of the third pair, and return to 1.000 at every even step.

None of these numbers is large against a dish’s stroke. The halfway state’s 8 per cent is about 20 mm at the corners of a building whose mass travels 274 mm in these records. But the 20 mm is avoidable for nothing, and it is the same order as the margin a designer adds to a stroke for everything nobody can calculate. A programme that costs the same in either order may as well be done in the order that leaves no twist, and the rule is short: replace in pairs opposite each other through the centre of mass.

Along and across

Half the plan replaced, and which way the ground moves. The six bearings of one half of the plan replaced, the largest bearing travel over the travel at the mass against their friction as a multiple of the other half's, shaken along the plan's length, across it and both ways. At 0.60, 1.000, 1.127 and 1.080; at 2.5, 1.000, 1.448 and 1.224.
Fig. 4 Half the plan replaced, the six bearings at one end at a multiple of the other six’s friction, shaken along the plan’s 30 m length, across it, and both ways. At 0.6, the ratios are 1.000, 1.127 and 1.080; at 2.5 times, 1.000, 1.448 and 1.224. A friction centre moved along the shaking leaves it no lever arm.

The halfway state of the end-to-end order has its friction centre moved 2.5 m along the plan’s length and not at all across it. Shaken along the length, its twist is nothing: the friction forces of the two halves differ, but they act along the line joining them, which passes through the mass, so their resultant has no lever arm. Shaken across the plan, the friction forces act perpendicular to that line and the 2.5 m is a lever arm of 2.5 m; the corner travel rises to 12.7 per cent above the mass’s at 0.6 and to 44.8 per cent at 2.5 times. Shaken both ways at once, the ratio is between the two, because for most of a record the plate slides obliquely and sees part of the lever. A sliding contact pushed two ways at once resists with one force of fixed size pointing against its velocity, the disc rather than the square of seventy-five per cent each way, so every bearing’s friction turns with the plate’s direction of travel and the lever arm the friction centre offers turns with it.

This is the rule the floor that twists in its own time gave for a mass’s eccentricity, and it applies to friction unchanged: an eccentricity matters only across the motion. It also says that the programme’s worst state is worst for an earthquake across the line along which the replacement walked. A building on a site whose strongest shaking is expected along one axis could choose the order that moves the friction centre along that axis, if it had to choose an order that moved it at all — but the pairs need no such choice.

Where the extra travel goes

Each bearing's travel with one half of the plan replaced. The largest travel of each of the twelve bearings, in millimetres, the mean of six records shaken both ways, with the six bearings at the plan's left half given 0.60 of the right half's friction. They range from 266 to 292 mm, against 240 at every bearing with no replacement; the mass travels 274.
Fig. 5 Each bearing’s largest travel in millimetres with the left half of the plan replaced at 0.6 of the right half’s friction, along the plan, for the three rows, the mean of six records shaken both ways. They range from 266 mm at the right-hand end to 292 mm at the left-hand far corner, against 240 at every bearing with nothing replaced.

The plan’s twist puts the extra travel at the end with less friction. With the left half’s friction at 0.6 of the right half’s the plate turns about a point towards the rough end, and the slippery end’s bearings swing further: 292 mm at the far left corner against 266 at the right end of the near row. Every bearing also travels further than with no replacement, because the plan now has less friction in total and dissipates less of each record: its mass travels 274 mm rather than 240. That part is not a twist, and it is the same for every order of replacement once the same number of bearings is done. A new bearing that is slipperier than the old ones lengthens every bearing’s stroke a little; one that is rougher shortens them. The order decides only how that change is shared across the plan.

The two effects should not be confused in a stroke check. The first, the travel of the building as a whole, is a property of the set and is settled by the final coefficient, whatever the order. The second, the twist, belongs to the visits between the first and last bearing and can be made nothing. A building whose dishes have a stroke margin of 50 mm can absorb either; one whose dishes were sized tight against a long-period site, where the ground has a period of its own near the isolated building’s, cannot afford to spend half the margin on a programme’s order.

When the mass is not at the middle

When the mass is not at the middle of the bearings. The worst step of two replacement orders, each new bearing at 0.60 of the old ones' friction, against the mass's offset across the plan: end to end, 1.080, 1.077, 1.080, 1.089; in opposite pairs, 1.023, 1.026, 1.031, 1.037; and the pairs counted only once each is complete, 1.000, 1.007, 1.014, 1.026, at offsets of 0.0, 1.5, 3.0, 4.5 m.
Fig. 6 The worst step of two orders against the mass’s offset across the plan, new bearings at 0.6 of the old ones’ friction. End to end, 1.080 at no offset and 1.089 at 4.5 m. Opposite pairs, 1.023 and 1.037; counted only at the steps where a pair is complete, 1.000, 1.007, 1.014 and 1.026.

The pairing rule leans on one thing the earlier essay made a point of not needing: that the two bearings of a pair carry the same load. With the mass at the centre of the plan, bearings opposite each other through the centre are equally loaded and a completed pair cancels exactly. With the mass 3 m off centre across the plan, the bearings on the heavy side carry more than their opposites, and a pair changed by the same factor no longer cancels: its contribution to ∑μiWiri\sum \mu_i W_i \mathbf{r}_i is proportional to the difference of the two loads. The friction centre after a completed corner pair stands half a metre from the mass rather than on it, and the corner travel exceeds the mass’s by 1.4 per cent. At 4.5 m of offset, 2.6 per cent.

That is a residue, not a failure. The end-to-end order’s halfway twist barely changes with the offset — 1.080 at none, 1.089 at 4.5 m — because its 2.5 m of friction eccentricity dwarfs anything the loads add; the pairs remain three times better at every offset. And the residue has its own repair: pair each bearing with whichever bearing on the far side of the mass carries the load that balances its moment, which on a regular grid with an off-centre mass is not the geometric opposite. The rule that survives is the general one: a pair is any two bearings whose changes leave ∑μiWiri\sum \mu_i W_i \mathbf{r}_i unmoved.

Which forces, and which equations

The free body is the plate, rigid, with its mass at one level and three freedoms: two translations and a rotation about a vertical axis. On it act twelve bearing forces. Each is a spring — the bearing’s load over the dish radius, times the bearing’s own displacement, which on a turning plate depends on where the bearing is — plus a friction force of the bearing’s coefficient times its load, along the bearing’s own velocity, reduced smoothly to nothing below a millimetre a second. The ground’s acceleration acts on the mass. Newton’s second law in each freedom is stepped explicitly at a millisecond for the sixteen seconds of each record and six seconds after it, and the largest travel of every bearing is read off. Each number in the figures is a mean over six pairs of records, the same six pairs for every case, so the differences between cases are differences in the bearings and not in the records.

The bearing loads are the plate’s weight shared by statics, a plane of loads whose resultant passes under the mass; they do not change during the record, which the bearing that does not know what it carries showed costs a negligible twist until a bearing lifts. The friction centre is computed from those loads and the coefficients alone, before any record is run, and it predicts the order of every curve in the figures: wherever it stands further from the mass across the motion, the plan twists more.

What the plate cannot show

The coefficients are constants. A sliding surface’s friction depends on its pressure, its velocity, its temperature and how far it has slid. The roller that is not a roller found a PTFE coefficient falling with pressure and doubling in the cold, and an old bearing and a new one will not follow those laws alike. The ratio of 0.6 used here is a stand-in for the difference between a worn surface and a fresh one, not a measurement of any product, and it may change with the season: a set whose old bearings are rougher in winter has a friction centre that walks with the temperature.

The floor is rigid. A real floor at the bearing level shares the bearings’ displacement only as far as it is stiff in its own plane, and the floor is a beam lying down is the check on that; a flexible floor lets a slippery bearing’s neighbourhood travel further on its own and turns part of the twist into in-plane bending.

The building stands on its bearings while they are changed, and here it does not. A replacement lifts the floor off one bearing on jacks beside it, and for those hours the building stands on eleven bearings and a pair of jacks. An earthquake in those hours is a different calculation, one about a plate with a stiff, frictional support where a bearing should be.

The dish radius is the same old and new. A replacement that is made to a different radius changes that bearing’s stiffness, not only its friction, and puts back the stiffness eccentricity the pendulum was valued for removing. That is the larger risk in practice, and it is the reason a replacement is specified to the original radius.

The records are synthetic and the means are of six. The ratios here are small, a per cent or a few, and individual records scatter around them by about as much. What is robust is the order of the four programmes and the return to the mass after each pair, which follow from the friction centre and do not depend on the records.

Still open: the old bearings that are not all equally old

Every old bearing here has one coefficient and every new one another. A real set that has run for thirty years is not uniform before anything is replaced: bearings in the sun and the shade, at the perimeter where water reaches them and in the middle where it does not, have aged differently, and a survey of breakaway friction, made when each is lifted, would find a pattern of its own. A replacement programme then starts from a friction centre that is not at the mass, and the best order is no longer the symmetric one: it is whichever sequence walks the existing friction centre back towards the mass, which might mean replacing the roughest corner first and its opposite last. Whether a programme can be chosen from the measured coefficients of the bearings as they are lifted, and whether the twist of an unreplaced, unevenly aged set is already larger than anything a careful programme adds, needs the old coefficients themselves — which nobody measures until a bearing is out.

Named alongside this one

Essays reaching for the same objects. Nobody chose these; they are what the concept index makes visible.

The objects this essay names

Each one links to every other essay that touches it.

Base isolationCentre of rigidityCoefficient of frictionFrictionNatural periodPlan torsion