Stub column — where it appears
Named by 2 essays across one field — each of them below, with the objects they name alongside it.
Two ways of buckling at once
A thin-walled column can bow as a whole or ripple in its plates, and each has its own critical load. The received advice is that the worst arrangement is the one where the two are equal. The arithmetic says the opposite — at coincidence the interaction costs two per cent, and the expensive region is where the plates go first.
A column nine hundred millimetres long
The patch-load check asks how much of a web a flange can spread a wheel over, and answers in a plate-buckling reduction that throws seven tenths of it away. A pair of stiffeners does not improve that answer. It replaces the question with a different one, from a different family, with a different failure in it.
Named alongside it
The objects these essays reach for when they reach for this one.
Section classificationSlendernessSquash loadBearing stiffenerCold-formedColumn curveCritical loadDirect strength methodEffective lengthEffective widthEigenvalueGlobal buckling