Concept

Shear stress — where it appears

Stress acting along a plane rather than across it, whose value is a property of the plane chosen and never of the point alone. It is equal on any two perpendicular planes at a point, which is the complementary shear that makes horizontal shear flow in a beam exist.

Named by 11 essays across 4 fields — each of them below, with the objects they name alongside it.

Shear stress across a section. The distribution of shear stress over an I-section, computed as VQ/It by accumulating the first moment of the area above every height. The peak is 0.41 against a mean of 0.19 — a ratio of 2.15 — and it falls at the neutral axis, where the bending stress is zero.

The shear nobody draws

A stack of loose planks slides at its ends when it is loaded. Glue them and the sliding stops — and whatever the glue is now carrying is a stress that no bending calculation contains.

sections · Shear flow
A fillet weld is stronger across than along. Capacity of a 4 mm throat over 100 mm, against the angle between the weld's axis and the load. Loaded along its length it carries 116.83 kN; loaded across it, 143.09 kN. The ratio is 1.22, which is √3/√2 exactly, and it comes out of the failure criterion rather than out of a test.

The weld that is stronger across than along

The same fillet weld, the same size, the same steel, carries twenty-two per cent more when the load runs across it than along it. The factor is exactly the square root of three over the square root of two, and it comes out of the yield criterion rather than out of a test.

connections · Weld strength
A buckled panel is a truss that nobody drew. A 1000 × 1000 panel of 6 mm web, at d/t = 167. It buckles in shear at 63.8 N/mm², which is 383 kN — and it then carries 696 kN, 1.82 times as much, because the tension diagonal takes over from the compression one that has gone. The band runs at 22.5° with a membrane stress of 252 N/mm² over a width of 541 mm, and it pulls on the flange at 221.3 N per millimetre of its length. A web that never buckled at all would have reached 953 kN, so the panel ends at 73% of a stocky web's capacity on a fraction of its steel.

The panel that carries more after it has failed

Everywhere else in this field a critical load is where the argument ends. A thin web is the exception — it buckles visibly, in waves anybody can see, and then goes on to carry nearly twice as much again by turning itself into a truss nobody drew.

stability · Tension field
One point, every plane through it, one circle. A point carrying 140 N/mm² across one face, 0 across the other and 45 of shear. As the plane is turned, the pair (σ, τ) runs round a circle of radius 83.2 centred at 70.0 — and it goes round at twice the rate the plane does, which is the part always misremembered and the part that makes the picture work. The principal stresses are 153.2 and -13.2, on planes 16.4° from the face the 140 acts on; the largest shear on any plane is 83.2, exactly the radius, and it sits 45° from those — which is 90° round the circle. The von Mises stress that ranks this state against any other is 160.2.

The worst stress is not where the worst bending is

Every stress this collection has quoted is a stress on a particular plane, and neither the bending stress nor the shear stress is a property of the point. Turn the plane and both change; one pair of numbers does not, and on a short beam it peaks where neither of them does.

sections · Principal stress
A check made on a perimeter, not on a section. One bay of a flat slab, 7.2 m square, on a 400 × 400 mm column. The heavy closed line is the control perimeter, 2d from the column face with its corners rounded at that radius — 4427 mm long against 1600 mm round the column itself. The shaded area inside it delivers no shear across it and is subtracted from the load; everything outside arrives through the perimeter. At 12 kN/m² that is 604 kN across 4427 × 225 mm, a shear stress of 0.606 N/mm² against a resistance of 0.658.

A check made on a perimeter, not on a section

Every shear check in this collection is made on a plane cut through a member. A slab sitting on a column has no such plane, because the shear leaves in every direction at once — so the check is made on a closed line, and a line grows with the column while the load grows with the square of the bay.

internal-forces · Punching shear
Two curves climbing together, and the one that catches up first. A 6 m member tapering from 200 to 600 mm, with the moment it carries and the moment it can carry drawn on the same scale below it. The demand rises linearly and the capacity as the square of the depth, so the gap between them closes and then opens again. It is narrowest at 3.00 m from the free end, where the member is 400 mm deep and 79% used, against 70% at the root where the moment is largest.

The section that changes along the span

A prismatic beam is checked where the moment is largest, and everyone knows where that is. A tapered one is not, because the capacity is moving too — and for a cantilever with a load at its tip the governing station is exactly where the depth has doubled, with no length, no load and no material in the answer.

sections · Tapered member
A section has two areas and the tables give one of them. Peak shear stress divided by the mean, for four sections of exactly the same gross area and depth. The mean is V/A and is the number a first calculation uses; the peak is what the material actually sees, and the ratio between them is a property of shape alone. A rectangle's is 1.5 — the parabola's peak over its average — and it is one of the few numbers in this subject that is exactly derivable and universally ignored. An I-section's is near 1.98, and the reason is on the second bar: 97% of the shear is inside a web that is 56% of the area. So the flanges carry the moment and almost none of the shear, and the web carries the shear and almost none of the moment — which is why a shear check on an I-section uses the web area and a moment check uses the whole section, and why the two checks are about two different pieces of steel.

The section has two areas

A shear force divided by the area of the section is not the shear stress anywhere in it. A rectangle's peak is exactly one and a half times that number and an I-section's web carries nearly all of the shear over a fifth of the area, which is why a moment check and a shear check on the same member are checks on two different pieces of steel.

sections · Shear area
One point, every plane through it, one circle. A point carrying 180 N/mm² across one face, 90 across the other and 40 of shear. As the plane is turned, the pair (σ, τ) runs round a circle of radius 60.2 centred at 135.0 — and it goes round at twice the rate the plane does, which is the part always misremembered and the part that makes the picture work. The principal stresses are 195.2 and 74.8, on planes 20.8° from the face the 180 acts on; the largest shear on any plane is 60.2, exactly the radius, and it sits 45° from those — which is 90° round the circle. The von Mises stress that ranks this state against any other is 170.6.

The circle nobody draws

A plane stress state has three principal stresses and the third is zero. When the two on the drawing share a sign, the largest shear in the state involves the one that is not there — and the circle a designer has drawn is not the circle that governs.

sections · Principal stress
A short timber beam is a shear problem, and a steel one never is. Utilisation of the bending and shear checks on one beam, against span-to-depth. The two cross where the ratio equals f_m ÷ f_v exactly — no load, no width and no span survives the cancellation — which for this timber is 6.7 and for steel is 1.73. So a timber beam shallower than about six times its depth is governed by shear parallel to the grain, and a steel beam would have to be shorter than twice its own depth before the same thing happened, which is not a beam. The third check is bearing across the grain, which does not move with the span at all: on the beam drawn it is at 0.40, and it is the one that governs.

The shear that decides a timber beam

A steel beam is never governed by shear, because its bending strength is only 1.73 times its shear strength and no beam is that short. Timber's ratio is 6.7 along the grain and 23 across it, so shear governs at proportions people build every day.

sections · Shear flow
A check made on a perimeter, not on a section. One bay of a flat slab, 7.2 m square, on a 400 × 400 mm column. The heavy closed line is the control perimeter, 2d from the column face with its corners rounded at that radius — 4427 mm long against 1600 mm round the column itself. The shaded area inside it delivers no shear across it and is subtracted from the load; everything outside arrives through the perimeter. At 12 kN/m² that is 604 kN across 4427 × 225 mm, a shear stress of 0.697 N/mm² against a resistance of 0.658.

Turn the column, and the slab passes

A flat slab that is comfortable under gravity fails its punching check the moment a moment arrives at the column, and nothing about the load has changed. The fix is not more concrete. It is the column's plan shape and, at equal area, which way round it is turned — worth more than adding half again as much column.

internal-forces · Punching shear
Force and capacity round a weld group, which do not vary together. Utilisation round the c shape group under 100 kN at 150 mm, walked from one end of the weld to the other, with the force scaled onto the same axis for comparison. The capacity is 1460 N/mm where the force runs along the weld and 1789 where it runs across it — √1.5 more — so the utilisation is not simply the force in different units. The worst point is at 47 degrees to the weld, where the capacity is 1612 N/mm, and the group carries 182 kN against the 165 the along-the-weld value would allow.

The weld that is stronger where it is pulled

A fillet weld pulled across its axis is √1.5 stronger than the same weld pulled along it. On a group under an eccentric load the direction of the pull varies from point to point, so the capacity does too — and the gain that follows is worth twenty per cent at one eccentricity and nothing at all at another.

connections · Weld strength

Named alongside it

The objects these essays reach for when they reach for this one.

Shear flowYield criterionFree bodyUtilisationVon misesControl perimeterDirectional methodEccentricityEffective depthFillet weldFirst moment of areaFlange

All concepts