Partial fixity — where it appears
Named by 2 essays across one field — each of them below, with the objects they name alongside it.
Stiffer than the model said
Measured natural frequencies of finished buildings come out between ten and sixty per cent above the values computed for them, consistently and in one direction only. Nothing on the list of reasons is a modelling error: every one is a real source of stiffness deliberately left out — and leaving stiffness out is conservative for deflection and unconservative for vibration.
The abutment that spreads before it turns
A fixed arch is fixed only if its abutments hold still, and they have two ways not to. Turning releases the springing moment, but slowly: an abutment has to be a hundred times the rib's EI/L to hold nine tenths of it, and a footing on stiff clay under a slender concrete rib already is. Spreading does the opposite. The rib's own shortening is worth 13.6 mm of spread, so an abutment that gives 7 mm a side under the thrust doubles every secondary moment in the arch — and a footing on dense sand gives 8.
Named alongside it
The objects these essays reach for when they reach for this one.
AbutmentArchAxial shorteningCalibrationComposite actionDampingDeflectionElastic centreFloor vibrationFootfallImposed deformationJoint stiffness