Floor vibration — where it appears
Named by 2 essays across 2 fields — each of them below, with the objects they name alongside it.
Also named here as footfall — the same set of essays touches all of them, so they are one junction rather than several.
The floor that is strong and unusable
A floor can satisfy every strength check, deflect less than the limit, and still be rejected by the people who work on it — because somebody walking across it at two steps a second happens to be exciting it at exactly the rate it likes to move.
Stiffer than the model said
Measured natural frequencies of finished buildings come out between ten and sixty per cent above the values computed for them, consistently and in one direction only. Nothing on the list of reasons is a modelling error: every one is a real source of stiffness deliberately left out — and leaving stiffness out is conservative for deflection and unconservative for vibration.
Named alongside it
The objects these essays reach for when they reach for this one.
DampingFootfallNatural frequencyServiceabilityCalibrationComposite actionDeflectionJoint stiffnessModal massMode shapeModellingNon structural stiffness