Concept

Fillet weld — where it appears

A weld laid in the corner between two surfaces, whose strength is taken on the throat rather than on either leg. It is stronger loaded across its length than along it, by about forty per cent, for a reason that is geometric rather than metallurgical.

Named by 6 essays across one field — each of them below, with the objects they name alongside it.

A fillet weld is stronger across than along. Capacity of a 4 mm throat over 100 mm, against the angle between the weld's axis and the load. Loaded along its length it carries 116.83 kN; loaded across it, 143.09 kN. The ratio is 1.22, which is √3/√2 exactly, and it comes out of the failure criterion rather than out of a test.

The weld that is stronger across than along

The same fillet weld, the same size, the same steel, carries twenty-two per cent more when the load runs across it than along it. The factor is exactly the square root of three over the square root of two, and it comes out of the yield criterion rather than out of a test.

connections · Weld strength
Throat stress round a fillet weld group. A c shape weld group carrying 100 kN at 150 mm from its centroid. The peak throat stress is 0.88 kN per mm of throat, at (79.5, -100); the worst point at maximum radius from the centroid carries 0.88. Checking by radius is right here, and points at identical radius differ by a factor of 1.

The corner that is not the worst point

Check the point furthest from the centroid. It is the standard rule for a weld group under an eccentric load, it is exactly right for some shapes, and for others it misses the peak by sixteen per cent — or picks one of four points it cannot tell apart whose stresses differ by two thirds.

connections · Weld group
Throat stress round a fillet weld group. A l shape weld group carrying 150 kN at 200 mm from its centroid. The peak throat stress is 2.17 kN per mm of throat, at (139.53, 100); the worst point at maximum radius from the centroid carries 1.99. Checking by radius is wrong here by 9.17%, and points at identical radius differ by a factor of 1.

The radius rule, and where it fails

A weld group under an eccentric load is checked at the point furthest from its centroid, on the reasoning that the stress from the twist grows with the radius. That reasoning ignores the direction the two stresses point in, and for one common shape it misses the peak by nine per cent.

connections · Weld group
Force and capacity round a weld group, which do not vary together. Utilisation round the c shape group under 100 kN at 150 mm, walked from one end of the weld to the other, with the force scaled onto the same axis for comparison. The capacity is 1460 N/mm where the force runs along the weld and 1789 where it runs across it — √1.5 more — so the utilisation is not simply the force in different units. The worst point is at 47 degrees to the weld, where the capacity is 1612 N/mm, and the group carries 182 kN against the 165 the along-the-weld value would allow.

The weld that is stronger where it is pulled

A fillet weld pulled across its axis is √1.5 stronger than the same weld pulled along it. On a group under an eccentric load the direction of the pull varies from point to point, so the capacity does too — and the gain that follows is worth twenty per cent at one eccentricity and nothing at all at another.

connections · Weld strength
The whole line works, and the axis is not a choice. A weld group 200 mm deep carrying 15 kNm about an axis in its own plane, together with 100 kN of vertical shear. The bending force per unit length runs linearly from 1125 N/mm at one extreme to the same the other way at the other, through zero at the group's own centroid — and the centroid is where the neutral axis is because a weld carries compression across its throat as readily as tension. The 250 N/mm of shear runs along the weld and is uniform over the whole 400 mm, so the two components are perpendicular to one another and are combined on the throat rather than added as vectors in the plane.

The eccentricity at right angles to the drawing

A bracket's load stands off the plane of its welds as well as being offset within it, and the second eccentricity produces a completely different object — bending about an axis through the group rather than torsion about a point in it. The weld line has no compression zone to argue about, so its neutral axis is its own centroid, and the whole length works.

connections · Weld group
Three fasteners, three completely different clocks. What each of three shear fasteners carries against how far the joint has moved. A 400 kN fillet weld is linear to 0.4 mm and then gone — it is stiff and it is not ductile. A 380 kN bolt in a hole 2 mm larger than itself carries nothing until the hole closes and then rises over several millimetres of hole elongation. A 250 kN preloaded bolt is at its slip resistance in under a tenth of a millimetre and holds it until it slips. Two of these in one joint are at the same displacement, so the one that gets there first carries the load — and the weld gets there 23 times sooner than the bearing bolt does.

Two fasteners that never arrive together

Every steel code forbids adding a weld's capacity to a bolt's in one shear joint, and states it as a rule rather than deriving it. It is derivable. Two fasteners in parallel are at the same displacement rather than the same force, and a weld has ruptured at four tenths of a millimetre while a bolt in a standard hole has not yet touched the side of it.

connections · Weld group

Named alongside it

The objects these essays reach for when they reach for this one.

Weld groupConnectionEccentricityBolt groupCentroidDirectional methodDuctilityFree bodyPlastic redistributionPolar second momentShear stressThroat stress

All concepts