Concept

Fillet weld — where it appears

A weld laid in the corner between two surfaces, whose strength is taken on the throat rather than on either leg. It is stronger loaded across its length than along it, by about forty per cent, for a reason that is geometric rather than metallurgical.

Named by 10 essays across one field — each of them below, with the objects they name alongside it.

A fillet weld is stronger across than along. Capacity of a 4 mm throat over 100 mm, against the angle between the weld's axis and the load. Loaded along its length it carries 116.83 kN; loaded across it, 143.09 kN. The ratio is 1.22, which is √3/√2 exactly, and it comes out of the failure criterion rather than out of a test.

The weld that is stronger across than along

The same fillet weld, the same size, the same steel, carries twenty-two per cent more when the load runs across it than along it. The factor is exactly the square root of three over the square root of two, and it comes out of the yield criterion rather than out of a test.

connections · Weld strength
Throat stress round a fillet weld group. A c shape weld group carrying 100 kN at 150 mm from its centroid. The peak throat stress is 0.88 kN per mm of throat, at (79.5, -100); the worst point at maximum radius from the centroid carries 0.88. Checking by radius is right here, and points at identical radius differ by a factor of 1.

The corner that is not the worst point

Check the point furthest from the centroid. It is the standard rule for a weld group under an eccentric load, it is exactly right for some shapes, and for others it misses the peak by sixteen per cent — or picks one of four points it cannot tell apart whose stresses differ by two thirds.

connections · Weld group
Throat stress round a fillet weld group. A l shape weld group carrying 150 kN at 200 mm from its centroid. The peak throat stress is 2.17 kN per mm of throat, at (139.53, 100); the worst point at maximum radius from the centroid carries 1.99. Checking by radius is wrong here by 9.17%, and points at identical radius differ by a factor of 1.

The radius rule, and where it fails

A weld group under an eccentric load is checked at the point furthest from its centroid, on the reasoning that the stress from the twist grows with the radius. That reasoning ignores the direction the two stresses point in, and for one common shape it misses the peak by nine per cent.

connections · Weld group
Force and capacity round a weld group, which do not vary together. Utilisation round the c shape group under 100 kN at 150 mm, walked from one end of the weld to the other, with the force scaled onto the same axis for comparison. The capacity is 1460 N/mm where the force runs along the weld and 1789 where it runs across it — √1.5 more — so the utilisation is not simply the force in different units. The worst point is at 47 degrees to the weld, where the capacity is 1612 N/mm, and the group carries 182 kN against the 165 the along-the-weld value would allow.

The weld that is stronger where it is pulled

A fillet weld pulled across its axis is √1.5 stronger than the same weld pulled along it. On a group under an eccentric load the direction of the pull varies from point to point, so the capacity does too — and the gain that follows is worth twenty per cent at one eccentricity and nothing at all at another.

connections · Weld strength
The whole line works, and the axis is not a choice. A weld group 200 mm deep carrying 15 kNm about an axis in its own plane, together with 100 kN of vertical shear. The bending force per unit length runs linearly from 1125 N/mm at one extreme to the same the other way at the other, through zero at the group's own centroid — and the centroid is where the neutral axis is because a weld carries compression across its throat as readily as tension. The 250 N/mm of shear runs along the weld and is uniform over the whole 400 mm, so the two components are perpendicular to one another and are combined on the throat rather than added as vectors in the plane.

The eccentricity at right angles to the drawing

A bracket's load stands off the plane of its welds as well as being offset within it, and the second eccentricity produces a completely different object — bending about an axis through the group rather than torsion about a point in it. The weld line has no compression zone to argue about, so its neutral axis is its own centroid, and the whole length works.

connections · Weld group
Three fasteners, three completely different clocks. What each of three shear fasteners carries against how far the joint has moved. A 400 kN fillet weld is linear to 0.4 mm and then gone — it is stiff and it is not ductile. A 380 kN bolt in a hole 2 mm larger than itself carries nothing until the hole closes and then rises over several millimetres of hole elongation. A 250 kN preloaded bolt is at its slip resistance in under a tenth of a millimetre and holds it until it slips. Two of these in one joint are at the same displacement, so the one that gets there first carries the load — and the weld gets there 23 times sooner than the bearing bolt does.

Two fasteners that never arrive together

Every steel code forbids adding a weld's capacity to a bolt's in one shear joint, and states it as a rule rather than deriving it. It is derivable. Two fasteners in parallel are at the same displacement rather than the same force, and a weld has ruptured at four tenths of a millimetre while a bolt in a standard hole has not yet touched the side of it.

connections · Weld group
Where each check bites. The c shape group with a 5.0 mm throat drawn to scale, loaded 1 mm from its vertical run. Offset from each weld, the use of each point: solid for the static directional check, dashed for fatigue at 2 × 10⁶ cycles, each scaled to its own worst point, which is marked. The static check's worst point is where the force runs most nearly along a weld; the fatigue check's is where it runs most nearly across one. Here the two checks are governed at different points, and a fatigue check made only at the static peak allows a load range 2.25 times the group's.

Strongest across, and first to crack across

A fillet weld pulled across its length is √1.5 stronger than one pulled along it, and every static check of a weld group uses that. In fatigue the same two directions are rated the other way round: the part of the force across the weld is checked against a detail category of 36 and the part along it against 80. The point of a group that governs the static check need not govern the fatigue one, and checking fatigue there can allow more than twice the load range the weld will take.

connections · Weld group
A plate pulled off an unstiffened flange. Looking down the column at a 250 × 20 mm plate on a 300 × 19 mm flange with a 11 mm web and 27 mm root radii, the plate pulled away from the flange. Shaded on the plate's welded edge: the force per millimetre of weld while everything is elastic, 47% of it entering over the web and its root radii and peaking at 2.67 times the uniform value at the toe of the radius. Dotted: the uniform force P/bp a rigid flange would give. Dashed: the same force spread over the effective width EN 1993-1-8 gives the joint, 191 mm — a plastic width, 2.8 times the 69 mm the elastic share fits at the web's average.

A quarter of the weld takes half the pull

A beam flange welded straight on to an unstiffened column flange is checked with an effective width of 191 mm out of 250. While the joint is elastic the plate's force does not use anything like that width: 47 per cent of it goes through the 65 mm over the web, and the flange has already yielded at 30 per cent of the force the rule allows. The rule's width is a plastic width, and the full-strength weld it insists on is what lets the joint get there.

connections · Weld group
The room left between two planes of braces. The surface of a 168.3 mm chord unrolled flat — along the chord across, round it up — with the footprints where 114.3 mm braces at 45 degrees are welded to it: two from a K joint in one plane (solid), two from a K joint in a plane 90 degrees round the chord (dashed), both nodes at the same section, each with a 12.6 mm gap between its own toes. The narrowest gap between a brace of one plane and a brace of the other is 6.5 mm, against the 12.6 mm two welds need: too little to weld. Each footprint spans 85.6 degrees of the chord's circumference.

Two planes of braces and one circumference

A tower leg or a triangular girder's chord receives K joints from two planes at once, and each can be checked as a planar joint: its gap, its eccentricity, its band. What the planar checks cannot see is that the two planes' braces are welded to the same tube. A 114 mm brace takes up 86 degrees of a 168 mm chord's circumference whatever its gap, so a square tower's two planes leave 6.5 mm between them where the welds need 12.6, and a triangular girder's braces land on each other. And two eccentricities at the edge of their band give the chord √2 or √3 times the moment the band was written for.

connections · Noding eccentricity
A doubler is put to work through its welds, and most of the work is at its ends. A 457 mm beam coped 200 mm long and 50 mm deep, carrying 300 kN, with a 8 mm doubler 393 mm deep on its web, the plate welded along its two long edges and running 200 mm past the end of the cope. The shaded bands along the two welds are the shear flow each passes into the plate, averaged over 50 mm: the top weld passes up to 1,056 N/mm and the bottom 821, both largest where the plate ends. At the cut through the cope's end the plate gives 92 per cent of the relief a plate joined at every point would give: the free edge is at 94 N/mm², against 152 as coped and 88 fully joined.

How far a doubler has to run

A doubler on a coped web is joined to the beam only along its welds, and the force reaches it through those welds from wherever it is welded. Stopped at the end of the cope, a plate welded along its two long edges gives about two fifths of the relief a fully joined plate would give at the very section it was put there for. Run on past the cope by four tenths of its own depth, it gives nine tenths. Welded all round, it is fully joined at any length.

connections · Coped beam

Named alongside it

The objects these essays reach for when they reach for this one.

Weld groupEccentricityConnectionBolt groupDuctilityPlastic redistributionThroat stressCentroidDetail categoryDetailingDirectional methodFatigue

All concepts