Tension — where it appears
Named by 6 essays across 3 fields — each of them below, with the objects they name alongside it.
The tie that spends an afternoon as a strut
A tension member is chosen by its area and nothing else. A compression member is chosen by how that area is arranged. So a member whose force reverses under some load case is not merely being asked for the same number with the other sign — it is being designed against a different variable, and the same steel can carry seventy times more or less depending on a shape nobody chose for that purpose.
Hung from the top, and nine per cent lighter
A tie is worth its full strength and a strut is not, so hanging the floors of a building from a hat truss ought to be an obvious economy. It is a real one, it is measurable, and it is nine per cent of the steel — shrinking as the building gets taller, which is the opposite of what the argument sounds like.
One drawing solves the whole truss
The method of joints solves a truss one joint at a time, and each solution is thrown away as soon as the next begins. Drawn instead of computed, the joints share their edges — every member's force appears once in a single figure, and the figure's own closure is the check.
Two diagonals, one of which is absent
A truss diagonal is sized for the shear in its panel, and near mid-span that shear changes sign depending on where the load stands. A member that can only pull cannot carry the reversed case, so the panel gets a second diagonal — and at any instant one of the pair is not there.
The wide side goes inside
A crane hook's section is a trapezoid with its broad face towards the centre of curvature, and that is not a casting convenience. Turn the same section round — same area, same depth, same moment — and the stress at the fibre that breaks rises by thirty-nine per cent. The shape is doing two things at once, and only one of them is in a straight beam's arithmetic.
The tension has to pull on something
A buckled web carries its shear on a diagonal band of membrane tension, and the band pulls sideways on the flanges and stiffeners that bound it. That pull is the design output nobody plots — it runs from 72 to 603 newtons per millimetre across ordinary panel proportions, it is largest exactly where the panel is most efficient, and at the end of the girder there is nothing beyond to take it.
Named alongside it
The objects these essays reach for when they reach for this one.
SlendernessBucklingLoad pathCompressionDeterminacyLoad arrangementLoad reversalPlastic hingeRobustnessTrussZero force memberAnchorage