Load factor — where it appears
Named by 2 essays across 2 fields — each of them below, with the objects they name alongside it.
Two ways of being wrong
Plastic analysis has two theorems and they point in opposite directions. Any equilibrium field that nowhere exceeds the plastic moment gives a load at or below the collapse load; any mechanism gives one at or above it. Only one of those errors is safe.
Four corners and a mechanism
The check on a hole in a web adds an axial stress to a local bending stress and compares the sum with the yield stress at one corner. What ends the opening is four hinges arriving together — and the gap between the two is a factor that varies along the span from two and a half to exactly one.
Named alongside it
The objects these essays reach for when they reach for this one.
Plastic hingePlastic momentCellular beamCollapse mechanismDuctilityEquilibriumInteraction diagramLimit analysisLower-bound theoremMechanismMoment redistributionPlastic neutral axis