Theme

The load that will not hold still — page 2

Essays 25 to 48 of 150 on this thread, in the same order.
The wind pushes on one face and pulls on three. A 30 × 20 m building in plan, with the measured pressure coefficient on each face and the arrows drawn in the direction the pressure acts. Only the windward face is pushed; the other three are sucked, and the side faces are sucked hardest of all at c_p = -0.7. The horizontal resultant is 842 kN at a velocity pressure of 0.9 kPa, and the arithmetic of it is the whole point: the leeward suction pulls the building downwind, so it ADDS, supplying 38% of the answer, while the two side faces cancel each other exactly and supply none of it. The coefficients are wind tunnel data; what is computed is the free body they are applied to. Equilibrium

Most of it is suction

A wind load is drawn as arrows pressing on the windward face, which is where about three fifths of it comes from. The rest is a pull on the back. The two side faces carry the largest suctions on the building and contribute nothing at all to the answer — and the inside of the building, which nobody draws, decides whether the roof stays on.

The force falls, the drift rises, and the damping goes the wrong way. What a compliant foundation does to a 0.6 s building on a 8 × 8 m footing, against the stiffness of the ground under it. Three curves, all normalised to the fixed-base answer. The period lengthens — 1.31 times at 200 m/s — because the swaying and rocking of the foundation are flexibilities in series with the structure's own, and the rocking term carries an h², so it is the tall building that feels it. The base shear falls with the period, which is why a fixed base is usually called conservative. The displacement rises, by 51% here, and that is what breaks the cladding, the services and the gap to the building next door. And the effective damping falls rather than rises: the structure's own is divided by the cube of the lengthening — 2.2% of an original 5% — while a slender building's foundation radiates only 0.28% back, because rocking radiates almost nothing at these frequencies. Dynamics

The ground is a spring

Every dynamic result in this collection has assumed a structure rising from something that does not move. Nothing does. A foundation can slide and it can rock, both are flexibilities in series with the structure's own, and the rocking one carries a square of the height — so the period lengthens, the force falls, the drift rises, and the damping goes the wrong way.

What the shape of a load in time is worth, for two load shapes. The peak displacement as a multiple of the static deflection, against the load's duration divided by the structure's natural period, for two load shapes: a load that rises linearly, then stays; a rectangular pulse, then nothing. The lines are closed forms and eight dots are the peak of a complete time integration of an oscillator of 0.300 s period under that load, agreeing with the line to within 0.19% everywhere. Dynamics

The load that is over before it has moved

A blast delivers an enormous pressure for a few milliseconds. Everything else in this field asks what force a structure can carry; a load that has come and gone before the structure has travelled any distance is not asking that question, and the answer turns out to depend on the mass and the ductility with the strength barely in it.

A broad tank sloshes and a tall one does not. The liquid's division into the part that moves with the wall and the part that sloshes, against the tank's proportion. The convective masses come from the potential-flow solution and the impulsive mass is whatever is left, so the two sum to the liquid's mass exactly at every proportion rather than approximately over part of the range. A tall tank at H/R = 3 is 84% impulsive and behaves almost like a solid; a shallow one at H/R = 0.5 is 72% convective and most of its contents never notice the earthquake. This tank sits at H/R = 1.33, which is 65% impulsive. Dynamics

The liquid has a period of its own

Shake a tank and its contents do not all go with it. Part of the liquid moves as though it were bolted to the wall and part sloshes at a period fixed by gravity and the radius, which the tank's stiffness has no influence over whatever. The split is decided by one proportion, and the two parts then take entirely different amounts of the earthquake.

The two braces balance until one of them buckles. An inverted-V brace after the compression member has gone. While both braces are elastic they carry equal and opposite forces and their vertical components cancel on the beam above, which is why the beam in a chevron bay is usually sized for gravity alone. The compression brace buckles at 445 kN and then sheds most of what it was carrying — 30% is left here — while the tension brace goes on to yield at 1065. The difference between the two vertical components is 659 kN, applied at the middle of the span with no help from either brace, and it asks the beam for 1317 kNm against the 200 kNm the gravity load asks for — 6.6 times as much. The beam drawn does not: 1517 kNm against a capacity of 731. The force is not a load case anybody applies; it is what the frame leaves behind on its way to the state it will actually be in. Structural form

The force the brace leaves behind

Two braces meeting under a beam carry the storey shear as a tension and a compression whose vertical components cancel, so the beam above sees nothing. They cancel only while both braces are elastic. Once the compression brace buckles it sheds most of its force, the tension brace goes on to yield, and the difference is a point load at midspan that nobody applied.

Every reason a building is stiffer than its model, added up. The computed natural frequency of a floor, and the same frequency after each source of stiffness that was deliberately left out is put back. Not one of them is a modelling error. Cladding and partitions are stiffness nobody is allowed to rely on for strength; a nominally pinned connection is never pinned; a slab acts with its beam whether or not shear connectors were provided; and concrete between the cracks is stiffer than a cracked section assumes. Together they multiply the stiffness by 1.83 and the frequency by 1.35, because a frequency is the square root of a stiffness, and every factor is halved on the way through. The asymmetry is the finding: leaving stiffness out makes a deflection conservative and a vibration check unconservative in the direction that matters, since a stiffer floor has a higher frequency and sits further from the footfall range. The model here reads 4.40 Hz against a 5.2 Hz criterion and fails it; the floor reads 5.95 Hz and passes. The correction that would have got it right is exactly the stiffness nobody is willing to count on. Deflection

Stiffer than the model said

Measured natural frequencies of finished buildings come out between ten and sixty per cent above the values computed for them, consistently and in one direction only. Nothing on the list of reasons is a modelling error: every one is a real source of stiffness deliberately left out — and leaving stiffness out is conservative for deflection and unconservative for vibration.

Four details, and no material anywhere on the plot. Stress range against cycles to failure for four detail categorys — 160, 112, 71, 36 N/mm² at two million cycles. The lines are parallel because they share a slope of three, and the spread between them is a factor of 4.4 in stress and therefore 88 in life. Nothing on this plot depends on the strength of the steel: the same detail in a grade twice as strong lies on the same line. At a stress range of 62 N/mm² the lives are 160: unlimited, 112: 2.1e+7, 71: 3.0e+6, 36: 3.9e+5 cycles. The knee in each line is the constant-amplitude limit, past which the slope becomes five. Connections

The detail decides and the steel does not

A fatigue check contains no material strength anywhere. The same detail in a steel twice as strong lies on exactly the same line, because a fatigue life is decided by the geometry of a weld and by the stress range it sees — and two per cent of the traffic does most of the damage, because life goes as the inverse cube of the range.

A restoring moment that gets smaller the further it leans. Restoring moment against rotation for a block 0.90 m wide and 4.20 m tall, both normalised — the moment by its value at first uplift, the rotation by the angle α = 12.1° at which the block topples. It is mgR·sin(α − θ), which is a weight times a geometry with no material property in it at all, and it has two features an elastic system does not. There is a jump at the origin: the moment is whatever the ground demands until uplift and then it is mgR sinα, so the law is discontinuous where a spring's is steepest. And the slope is negative — the further it leans the less it pushes back — so the equilibrium at θ = 0 is stable only because of that jump, and there is no stiffness to divide into a mass. The straight line is what a spring of the same first-uplift strength would have done. Dynamics

The block that is safer for being bigger

A block resting on the ground lifts off at an acceleration that depends only on its shape and not at all on its size, and then falls over at one that depends strongly on its size. Two objects of identical proportion begin rocking at the same instant and only the smaller one topples — which is why the slender water towers stood in Chile and the squat tanks beside them did not.

Two frequencies that meet, and a determinant that never moves. The two natural frequencies of Ziegler's two-bar column against the follower load Pℓ/k, with the determinant of its stiffness matrix drawn along the top. The determinant is k² at every load — it varies over this whole axis by 1.1e-16 of itself, which is round-off — so a static buckling analysis of this structure finds no critical load whatever and reports it as stable everywhere. The frequencies say otherwise: they approach, meet at Pℓ/k = 2.0858, the closed form (7 − 2√2)/2, and become a complex pair, which is oscillation that grows. With no damping that merge is also where the column goes unstable. Adding any internal damping at all drops the load at which that happens to 1.4643, which is 41/28 and 30% below the undamped value; the limit of the damped system is not the undamped system, which is the paradox Ziegler found in 1952 and which was taken for an arithmetic error for a decade. Stability

The load it cannot buckle under

Every stability calculation on this site rests on an assumption nobody states: that the load has a potential, so a critical load is where a total potential energy stops being a minimum. A load that turns with the structure it is pushing has no potential, and the static analysis of such a column returns no critical load at all — a determinant that never vanishes, for a column that fails at a perfectly finite one.

The same steel, brittle in January. Fracture toughness against temperature for a 25 mm ferritic plate, from Wallin's master curve — 30 + 70·exp(0.019(T − T₀)) in MPa√m, whose shape is the same for every ferritic steel and whose only free parameter is the reference temperature T₀ = -60 °C. Beside it, and on its own scale, is the crack length that toughness will tolerate at 200 N/mm², which goes as the square of it. At +20 °C this plate carries a 764 mm flaw and at -20 °C it carries 199 mm — a factor of 3.8 for a forty-degree change in the weather, in a steel that met its specification on both days. Thickness moves the curve as well, and the wrong way: constraint at a crack tip suppresses the yielding that would have blunted it, so a 100 mm plate of this steel tolerates 27% of the flaw a 10 mm plate does. Loading it in a millisecond shifts the whole curve another forty degrees. Materials

The same steel, brittle in January

Every other material property in this collection is a number. Toughness is a curve, and the axis it runs along is temperature. Between twenty degrees and minus twenty a structural steel does not get gradually weaker — it changes the mechanism by which it fails, and the flaw it will tolerate falls by a factor of four.

The ground is a structure, and it has a period. The transfer function of 38 m of soil at 75 m/s over bedrock at 800 m/s: how much the surface moves for a given motion in the rock, at every frequency. It is a column fixed at the bottom and free at the top, so its resonances are the odd harmonics — the peaks stand at 1, 3, 5, 7 times the first, which is a fixed-free column and nothing else. The fundamental is at 0.493 Hz, a period of 2.03 s, and it is 4H/v_s exactly. The peak amplification is 7.5 against the bound 1/(α + πξ/2) = 7.5, which agrees to 0.2% — and the α in it is the impedance ratio, 0.0554 here. That is the term that keeps the answer finite: assume rigid bedrock and α is zero, the bound becomes 13 and the model is predicting an amplification set by damping alone. What limits the surface motion is that the energy can leave downward. Dynamics

The ground has a period of its own

An earthquake is measured on rock and felt on soil, and between the two is a layer that behaves exactly like a structure — a column fixed at bedrock, free at the surface, with a fundamental period of four times its depth over its shear wave velocity and a set of odd harmonics above it. The motion a building receives is the rock motion through that filter, and the filter is sharp.

The resonance that ran out of time. The response of a 0.100 s oscillator at 2.0% damping while the driving frequency sweeps up through its own, plotted against the driving frequency rather than against time. The steady-state amplification is 1/2ζ = 25; this sweep reaches 23.6, which is 95% of it, because the time spent inside the half-power band is a limited number of build-up time constants. The whole answer depends on one group, β/ζ²ω², and over the range this figure's sibling sweeps the fraction falls from 100% to 41%. Two features fall out of the integration and neither is guessable from the steady-state picture: the peak arrives after the frequency has passed resonance, by 1.2% of it here, and the response beats afterwards at the difference between the two frequencies. A machine's instrument therefore reads its largest amplitude while it is already above its critical speed. Dynamics

The resonance that ran out of time

A resonance amplifies by one over twice the damping, which for a lightly damped structure is fifty or a hundred. That is a steady-state answer and it takes time to arrive — with a time constant containing the same small damping — so nothing that sweeps through a resonance ever collects all of it, and past a certain rate the peak reached stops depending on the damping at all.

The abutment force is the sag turned upside down. A 100 m ribbon carrying 35 kN/m at a sag of 2.0 per cent of its span. H = wL²/8f, so the horizontal force at each abutment is 21875 kN — 6.25 times the entire weight of the deck, and five times what a suspension bridge of the same span and weight at a tenth would have needed. The curve is a reciprocal and it has no flat part: halving the sag doubles the force, at any sag. What stops a designer flattening it further is not the ribbon, which is in tension and cannot buckle. It is what the ground at each end will take, and at 6.25 deck-weights that is usually rock or a very large anchor block. Structural form

The deck that is its own cable

Every other cable structure hangs something from the cable. A stressed ribbon hangs nothing — the walking surface is the catenary, laid at a fiftieth of the span rather than a tenth, because a footbridge has to be walkable. That one decision hands the abutments six and a quarter times the entire weight of the bridge.

Buildings that sway alike need almost no gap between them. The separation two adjacent buildings need, against the ratio of their periods. The obvious answer is the sum of what each can do — 340 mm — and it is wrong, because the two peaks do not occur at the same instant. The right combination is the one modal responses use, √(u₁² + u₂² − 2ρu₁u₂), with ρ the cross-correlation coefficient of the two responses. ρ depends on the period ratio and behaves the opposite way to intuition: at a ratio of one the two buildings sway together, ρ = 1, and the gap collapses to the difference of the two, 100 mm. At the 0.57 drawn ρ is 0.029 and the gap is 248 mm — 27 per cent less than the sum, and 99 per cent of the square root of the sum of squares. Dynamics

The gap between two buildings

Two towers side by side in an earthquake need a gap. The obvious answer is the sum of what each can move, and it is wrong — because the two peaks do not happen at the same instant. What decides the answer is the ratio of the two periods, and buildings that sway alike need almost no gap at all.

Evenly spaced modes, so one of them is always where the feet are. The first 6 modes of a 120 m stay under 3.50 MN. A taut string's frequencies are an arithmetic progression — every one of them 1.006 Hz above the last — where a beam's go as the square of the mode number and spread out. That difference is the whole of why a cable is a lively member and a beam is not: a beam has a first mode and then a gap, and a cable has a mode every 1.01 Hz for ever. The shaded band is ordinary walking, 1.6 to 2.4 Hz, and mode 2 sits inside it. Nothing about the tension can move a mode out of the band without moving another one in. Dynamics

The force read off a frequency

Nothing can measure the tension in a stay cable directly — there is no gauge, no accessible end and no place to put a load cell. What there is, is a member whose frequencies are an arithmetic progression whose spacing is the square root of its own tension, so a phone taped to it for thirty seconds returns the force.

Seventy per cent of the strength and ninety of the stiffness. Strength and modulus against age, each as a fraction of its own twenty-eight-day value. They do not move together: E follows f to the power 0.3, so at seven days the concrete has 78 per cent of its strength and 93 per cent of its stiffness, and at three days 60 and 86. A young structure is much nearer its final deflection than its final capacity. The 20 N/mm² a striking calculation asks for arrives at 2.2 days at 20 °C, 4.6 at five degrees and 1.7 at thirty-five. Materials

The strength it had on the day

Every concrete strength a design quotes is a twenty-eight-day cylinder value, and a structure is loaded long before that — formwork struck at three days, the next storey cast at seven, a prestressing force transferred at two. The number that existed at the moment the load arrived is a different one.

Where the demand crosses the capacity. Base shear against roof displacement for a eight-storey frame pushed with a triangular load pattern. It is elastic to 1994 kN, where the first storey reaches its shear capacity, and flattens as each of the others follows — 7 yield events in the order 3, 4, 2, 1, 5, 6, 7. The demand is a displacement rather than a force: the elastic spectrum at the building's own period of 0.93 s gives 173 mm, and the participation factor of 1.26 makes that 219 mm at roof level. Against an idealised yield of 70 mm that is a ductility demand of 3.10. Dynamics

Pushed over until it will not stand

A structure in an earthquake is asked for a displacement rather than a force. A pushover answers a different question cheaply — how much base shear the frame has against how far its roof moves — and the whole art is in what happens when the two are laid over each other.

The loop a brace has when it cannot buckle. Force against axial deformation for two braces with the same core area, cycled six times at a storey drift of 2 per cent. An ordinary brace yields at 900 kN in tension and buckles at 482 in compression — 54 per cent of it — and the buckled shape leaves a plastic hinge that does not straighten, so the compression side loses capacity every cycle and is at 12 per cent of its first value by the last. A restrained brace has a casing that carries no axial force at all and only holds the core straight, which decouples axial capacity from flexural stiffness — the coupling that makes a strut weaker than a tie — so it yields at the same force both ways and hardens instead. The energy dissipated is 2.07 times as much over the six cycles, and the casing has to satisfy one inequality: π²EI/L² above the fully hardened core force, 2.56 here, which is a buckling check on a member carrying nothing. Dynamics

The brace that yields both ways

An ordinary diagonal yields in tension at its full strength and buckles in compression at half of it, and the buckle leaves a hinge that does not straighten. Stop it buckling with a sleeve that carries no load at all and the loop becomes symmetric.

The building is a filter with one very sharp tooth. What a component mounted on the roof of a eight-storey building feels, divided by what the same component would have felt on the ground. A rigid item sees the floor's peak acceleration rather than the ground's, which is already 2.29 times as much. An item whose own period matches the building's sees 6.1 times as much, at 0.94 s — a resonance inside a resonance, and the two amplifications multiply rather than add. Far above the building's period the ratio falls back toward one, because a component much softer than its support simply follows the ground. The shape of this curve is a property of the building and not of the earthquake, which is why equipment is qualified against a floor spectrum rather than a ground one. Dynamics

The spectrum a floor hands on

Most of what breaks in an earthquake is not the structure. It is a transformer, a chiller, a rack, a ceiling, a pipe — and every one of them is bolted to a floor rather than to the ground. The motion it feels has already been through a filter with one very sharp tooth in it.

The summer that is worse than the one before it. The earth pressure behind an integral abutment, summer by summer, as a multiple of the at-rest value it started at. A 60 m deck expands by 10.8 mm at each end and pushes the abutment into the backfill. Granular soil under cyclic strain densifies, so the same movement next year needs a higher pressure to achieve, and K climbs from 0.38 toward 0.96 — a factor of 2.49 on the force, reached after about a century. The design load on an integral abutment describes the bridge's whole life rather than a load case, and it is the only load in this collection that gets larger because time has passed rather than because something was added. Structural form

The summer that is worse than the last

An expansion joint is a hole in a deck that leaks salt water onto the bearings underneath it. Remove it and the thermal movement does not go away — it goes into the soil behind the abutment, twice a day for a hundred and twenty years, and granular soil under cyclic strain gets denser.

Every section is hogged and sagged before the bridge exists. The bending moment envelope of a launched deck, section by section along its own length, taken over every position of the launch. In service each section has one sign; during the launch 100 per cent of them see both, because each passes over every pier and through every span on its way out. The worst launch moment is 42568 kNm against 40500 in service, and with no launching nose at all it would be 185977. That is why a launched bridge is a constant-depth box with symmetric flanges: the design case is not a load, it is a history. Structural form

Every section was somewhere else

A bridge pushed out over its piers subjects each of its cross-sections to a history rather than to a load case. Every one passes over every support and through every span, so the design envelope is the envelope of envelopes — and no in-service condition produces it.

Which of them stops moving. Three load cases on the same rectangle, each a constant moment plus a temperature profile cycled from nothing to a peak and back, over sixteen cycles. At 20% of the plastic moment with a 40°C profile it never yields at all; At 50% of the plastic moment with a 150°C profile it shakes down; At 90% of the plastic moment with a 260°C profile it ratchets, at 51.0% of the first-yield curvature per cycle. The ratcheting case never collapses and never returns: it simply arrives somewhere further round every cycle, which is a serviceability failure that no collapse calculation contains. Materials

The map with three regions

A structure carrying a constant load and a cycling temperature has three possible fates and only one of them is a collapse. It can stay elastic, it can yield once and then stop, or it can gain a little more deformation every cycle for ever — and the third has no failure load at all.

Yielding one way makes it easier to yield the other. Mild steel taken to a strain of 1.20% and then pushed back the other way. The stress falls by 550 N/mm² before it yields again, against a yield stress of 275 — the elastic range is twice the yield stress and not once it, which is the Bauschinger effect and is a consequence of the yield surface sliding rather than growing. Materials

Yielding one way, and then the other

A material that has yielded in tension yields earlier in compression than it did the first time, and by an amount that is exactly what makes its elastic range twice its yield stress rather than once it. That is a property no monotonic test reports and every reversing structure depends on.

The stress that leaks away. A restrained shrinkage strain of 320 microstrain in concrete of modulus 34000 N/mm². Ignoring creep it produces 10.88 N/mm², which is above the tensile strength of 3.8 and predicts that every restrained concrete member ever cast has cracked. Counting creep by the superposition integral leaves 1.72 N/mm² after 55 years, and the one-line age-adjusted shortcut at the usually quoted ageing coefficient of 0.8 leaves 3.05. The two disagree — this creep function implies an ageing coefficient of 1.67, not 0.8 — and both are below the tensile strength, so the conclusion turns on counting creep at all rather than on how it is counted. Materials

The stress that leaks away

Creep makes a load's deflection grow and an imposed strain's stress shrink, and the second is why restrained concrete does not crack as often as an elastic calculation says. The same material property runs both ways, and which way it runs depends on whether the structure was given a force or a movement.

All themes