Generator

The load that makes itself worse — the P-delta generator

Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached.

The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached.

15 essays call p-delta. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

The column curve. Failure load against slenderness, as a fraction of the squash load. A stocky column crushes; a slender one buckles at the Euler load; the crossover is where the two curves meet, and real columns fall below both near it. Stability

Strong enough and still falls over

A column can fail at a fraction of the load its material could carry, by going sideways. Buckling is a failure of stability rather than of strength, and it is decided by geometry.

The ends decide the length that matters. Four columns of identical height and section, buckling under four sets of end conditions. The effective length factor is the fraction of the column that behaves like a pin-ended one, and the buckling load goes as its inverse square. Stability

The ends decide the length that matters

Four columns of identical height and section, buckling at loads sixteen times apart. Nothing differs but what is holding the two ends.

The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached. Stability

The load that makes itself worse

A structure that has leaned carries its weight off the axis, which makes it lean further. The amplification is one over one minus the load ratio, and it runs away long before the buckling load.

A column that was never straight. Load against lateral deflection at mid-height, for a column starting with an initial bow of 0.002. There is no critical value to reach: the deflection grows from the first increment, slowly at first and then without bound as the ratio approaches 1.00 — which is the Euler load, and which the column therefore never attains. The perfect column, drawn for comparison, sits on the vertical axis until it arrives there and then has no answer at all. Stability

The column that was never straight

Euler's load is the load at which a perfectly straight column becomes indifferent to being bent. No column is perfectly straight, so no column ever reaches it — and the load it never reaches can still be measured.

The water that will not run off. Water depth against sag at the middle of the bay, for a roof bay starting with a reversed construction camber of 0.01. There is no critical value to reach: the deflection grows from the first increment, slowly at first and then without bound as the ratio approaches 1.00 — which is the depth at which the bay fills faster than it stiffens, and which the roof bay therefore never attains. The perfect roof bay, drawn for comparison, sits on the vertical axis until it arrives there and then has no answer at all. Deflection

The water that will not run off

A flat roof deflects, the deflection makes room for water, the water deepens the deflection. It is the same equation as a buckling column, with rain in place of the axial load.

Two shapes that are the wrong way up for each other. Deflected shapes of a 20-storey building under a uniform wind, drawn to the same scale. The wall alone bends: its shape is flattest at the base and steepest at the top, reaching 146 mm. The frame alone shears: it is steepest at the base where the storey shear is largest, reaching 140 mm. Tied together at every floor they reach 58 mm — less than a quarter of either, and less than the 72 mm two springs in parallel would give, because each is stiff exactly where the other is not. Structural form

How a tall building stands still

A shear wall bends and a framed tube shears, and the two deflected shapes are the wrong way up for each other. Tie them together at every floor and the pair is stiffer than the sum of their stiffnesses — because near the base the wall holds the frame back and near the top the frame holds the wall.

One drift, two motions, opposite curvatures. The sideways movement of a 120 m building under a uniform wind, drawn as the sum of the two mechanisms that produce it. The bending curve is a cantilever's: flat at the base, steepening upward, concave one way. The racking curve is a stack of parallelograms: steepest at the base and flattening, concave the other. They add to 366 mm at the roof, of which 61% is bending. The one group that decides the split is αH = H√(GA/EI) = 2.48: below one the racking dominates and the building behaves as a frame, above about six the bending does and it behaves as a cantilever, and everything interesting is in between. Deflection

Two motions with one name

A tall building's sway is two movements added. A frame racks like a stack of parallelograms, worst at the bottom; a cantilever bends about its base, worst at the top. The total at roof level says nothing about which storey is worst, and on this building it is neither.

The deflection goes on growing, and sometimes it does not stop. Second-order deflection of a sustained-loaded concrete column against age, on a log time axis. Creep takes the effective modulus down, which takes the buckling load down with it — from 11580 kN on the day to 3309 in the long term, 29 per cent of it — so the amplifier 1/(1 − N/N_cr) grows even though nothing was added to the load. At 2200 kN the column settles: 25 mm of eccentricity on the day and 60 mm at the end, a factor of 2.4 for a load that never changed. At 5294 kN — still only 46 per cent of the day-one critical load — it does not settle, and the divergence arrives at 55 days for no new reason at all. Stability

The column that fails years later

A concrete column under sustained load goes on straining at constant stress, so its deflection grows — and because the second-order moment is the load times that deflection, the demand grows with it. There is a load below which the two settle and one above which they never do.

The demand falls and the movement rises, by the same factor. One elastic spectrum read twice: as an acceleration on the left and as the displacement that goes with it on the right. A fixed-base building at 0.5 s sits on the plateau and is asked for 1.05 g. Put it on bearings soft enough to make its period 2.54 s and the demand falls to 0.103 g — a base shear 10.2 times smaller, bought with no strength whatever. The same shift on the right-hand plot goes the other way: displacement is S_a T²/4π², so the demand rises from 65 mm to 165. That number is the design. It is a gap all the way round the building, a moat every service has to cross, and a detail that a later contractor will fill in unless somebody says what it is for. Dynamics

Made weaker on purpose

Everything else in this collection resists a load by being stiff or strong enough for it. A base-isolated building resists an earthquake by refusing to hear it — a layer of bearings under the whole structure with a lateral stiffness a twentieth of the frame's, bought with almost no strength at all.

The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached. Equilibrium

The load that is really a lean

No frame is ever plumb. The columns are out of upright by something like a three-hundredth, and every tonne of gravity load standing on that lean has a horizontal component. The force that represents it is not a safety allowance — it is an exact statics substitution for a geometry nobody drew.

Effective length is a property of the storey. The effective length factor of the one column that resists sway, against the total gravity load on the storey as a multiple of its own. At the left-hand end it carries the storey alone and its K is 1.99 — the 2.0 every chart gives a column fixed at the base and free to sway at the top, reproduced here by a route that never mentions a chart. Then columns are added that have pinned bases and therefore no lateral stiffness whatever. They contribute load and nothing else, so they cannot buckle on their own and they lower the load at which everything buckles together. K rises as the square root of the load ratio, exactly, and at the storey drawn — three leaning columns carrying 69% of the gravity load — it is 3.57. That is off the end of every published alignment chart, and the leaning columns themselves, which a designer would take at K = 1.0 for pinned ends, are at 2.54. Stability

The column that leans on its neighbours

A column with a pinned base and a pinned top has no lateral stiffness at all and cannot stand up alone, and yet thousands of them do. What holds them is the rest of the storey, and what it costs is paid by whichever columns do have stiffness — whose effective length rises as the square root of the load being leaned on them, straight off the end of every chart.

The load being amplified is not the load doing the amplifying. The sway amplifier 1/(1 − ΣP/P_cr) against the storey's total gravity load, as columns are added that carry load and provide no lateral stiffness. The critical load of the storey is fixed at 8203 kN by the bracing that exists, and every leaning column moves the structure along the axis without changing it. At the storey drawn the amplifier is 1.57, so the second-order sway moment is 57% on top of the first-order one — and none of that 70% of the load which is causing it appears in any stability calculation done column by column. The storey stays stable across the whole of this axis. That is the practical reason a gravity-only column is drawn on the frame model rather than designed on its own: it is not being checked, it is being counted. Stability

Counted, not checked

A column with pinned ends and no bracing cannot buckle on its own, so nothing about it fails a stability check. It still carries load, and load with no stiffness attached lowers the buckling load of everything around it — which is why a gravity-only column is put on the frame model and never designed by itself.

Wrong in both directions until the building racks. Across buildings from a pure bending tower to a pure racking frame (αH on a logarithmic scale), each 20 storeys with gravity putting its own critical factor at 5.0: solid, the least storey sway factor over the building's own, which is what taking the least storey as the building's costs; dashed, the ground storey's second-order increase estimated from its own sway factor, over the true increase. At αH = 0.1 the least storey factor is 0.77 of the true one and the ground storey's estimate 0.09 of the true increase; at αH = 10, 0.86 and 0.37; at αH = 100, 0.94 and 0.98. The first error is on the safe side and the second is not, and both vanish only for a building that racks. Stability

The storey that cannot see the building lean

A sway check made storey by storey asks each storey how much it drifts under a push and how much gravity sits on it, and reads a critical load factor for the storey from the two. For a frame whose storeys rack like a stack of shelves that is exact. For a building that bends — a braced core, a wall — it is wrong twice. Taking the least storey as the building's reads a critical factor of 3.9 for a building whose own is 5. And amplifying each storey by its own factor finds a 2 per cent second-order increase at the ground storey, where the truth is 20, because the ground storey hardly drifts and carries the lean of everything above it.

The buckling mode moves up to where the spine is not. The building's first buckling mode, each floor's sideways movement as a fraction of the roof's, up the height of a 20-storey building of a bending spine and a racking frame (αH 1.0), its gravity scaled to an elastic critical factor of 5.0, under an equal lateral load at every floor: the spine to the roof, and stopping at storeys 15 and 10. With the spine to the roof the mode is the bending tower's, growing all the way up. With the spine stopping, at storey 15 its top moves less than a thousandth as far as the roof, and at storey 10 its top moves less than a thousandth as far as the roof: the building buckles in the first storey of frame above the spine, every floor above that storey moving with it as one, and the spine takes no part. Stability

The storey above the core decides

A building whose bending core runs to the roof shares one sway mode between its core and its frame, and the storey-by-storey stability check reads it wrongly twice. Stop the core five storeys short and the check becomes exact: the first storey of bare frame above the core reads the building's own critical factor to three figures, because the whole building buckles there and nowhere else. The check stays wrong below the core, and it goes wrong again when the frame above is more than about twice as stiff.

A hat makes the top storeys look stiff. Each storey's own sway factor α up the height of a 20-storey building of a core to the roof and a racking frame (αH 1.0), its gravity scaled to an elastic critical factor of 5.0, under an equal lateral load at every floor: with no hat, with a hat truss at the roof holding the core's rotation with 10 times the core's EI/H, and with the same restraint at storey 10; the building's critical factor 5.0 as a vertical line. With no hat the top storeys read the least, 4.06 at the roof. With the hat the roof storey reads 15.47 and the least, 4.14, has moved down to storey 9. With the outrigger at mid-height the least is back at the top, 3.85. Stability

The hat that hides the lean

A hat truss on a core-and-frame building holds the top of the core, nearly doubles the building's critical load, and makes its top storeys look three or four times as stiff as they did. The storey check believes them. Under the hat the roof storey reads a sway factor of 15 and estimates 7 per cent of second-order drift; the building still buckles leaning, and the roof storey's true increase is 24 per cent. The hat turns the storey check from pessimistic to unsafe at exactly the storeys it was built to stiffen.

The library, page 3 of 7 — where p-delta sits