The load that makes itself worse — the P-delta generator
The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached.
12 essays call
p-delta. The drawing above is what it returns with no arguments at all; every
call below passes it something, because a placement that passes nothing draws whichever
member of the family the generator happens to default to rather than the one its essay
argues about.
Where it is called
Changing this generator changes every one of these figures.
Strong enough and still falls over
A column can fail at a fraction of the load its material could carry, by going sideways. Buckling is a failure of stability rather than of strength, and it is decided by geometry.
The ends decide the length that matters
Four columns of identical height and section, buckling at loads sixteen times apart. Nothing differs but what is holding the two ends.
The load that makes itself worse
A structure that has leaned carries its weight off the axis, which makes it lean further. The amplification is one over one minus the load ratio, and it runs away long before the buckling load.
The column that was never straight
Euler's load is the load at which a perfectly straight column becomes indifferent to being bent. No column is perfectly straight, so no column ever reaches it — and the load it never reaches can still be measured.
The water that will not run off
A flat roof deflects, the deflection makes room for water, the water deepens the deflection. It is the same equation as a buckling column, with rain in place of the axial load.
How a tall building stands still
A shear wall bends and a framed tube shears, and the two deflected shapes are the wrong way up for each other. Tie them together at every floor and the pair is stiffer than the sum of their stiffnesses — because near the base the wall holds the frame back and near the top the frame holds the wall.
Two motions with one name
A tall building's sway is two movements added. A frame racks like a stack of parallelograms, worst at the bottom; a cantilever bends about its base, worst at the top. The total at roof level says nothing about which storey is worst, and on this building it is neither.
The column that fails years later
A concrete column under sustained load goes on straining at constant stress, so its deflection grows — and because the second-order moment is the load times that deflection, the demand grows with it. There is a load below which the two settle and one above which they never do.
Made weaker on purpose
Everything else in this collection resists a load by being stiff or strong enough for it. A base-isolated building resists an earthquake by refusing to hear it — a layer of bearings under the whole structure with a lateral stiffness a twentieth of the frame's, bought with almost no strength at all.
The load that is really a lean
No frame is ever plumb. The columns are out of upright by something like a three-hundredth, and every tonne of gravity load standing on that lean has a horizontal component. The force that represents it is not a safety allowance — it is an exact statics substitution for a geometry nobody drew.
The column that leans on its neighbours
A column with a pinned base and a pinned top has no lateral stiffness at all and cannot stand up alone, and yet thousands of them do. What holds them is the rest of the storey, and what it costs is paid by whichever columns do have stiffness — whose effective length rises as the square root of the load being leaned on them, straight off the end of every chart.
Counted, not checked
A column with pinned ends and no bracing cannot buckle on its own, so nothing about it fails a stability check. It still carries load, and load with no stiffness attached lowers the buckling load of everything around it — which is why a gravity-only column is put on the frame model and never designed by itself.